Cummins/Onan 1.4 EGSAA Generator Set

The Cummins/Onan 1.4 EGSAA is a 120 kW (1400 kVA) Gasoline standby generator set powered by a Cummins/Onan 1.4EGSAA engine. It is available at 120 V, single-phase, 60 Hz and rated 10 A. It holds about 0.95 L (0.3 gal) of oil and 0.95 L (0.3 gal) of coolant, with a maximum ambient rating of 32 °C. Starting uses 1 group-12 battery at 12 V. The set measures 26.8×597×406 mm (1.1×23.5×16.0 in) and weighs about 59 kg (130 lb). An integrated tank holds 6 L (1.6 gal), roughly 3.3 hours of runtime.

120 kW
Standby
1.4 L
Displacement
0.95 L
Oil capacity
1
Document types

How to read your Cummins/Onan serial & model number →

Specifications

FuelGasoline
Frequency60.0 Hz
Standby power120 kW
Standby kVA1400
Prime power10 kW
Oil capacity0.95 L
Alternator1.4EGSAA (2-pole, Class B insulation)
Voltage options120 V
PhaseSingle
Rated current10.0 A
Power factor1-1
Circuit breaker12.5 A
Battery group12x5
Battery voltage12 V
Battery quantity1
Coolant capacity0.95 L
Max ambient32 °C
Dimensions (L×W×H)26×597×406 mm
Dry weight59 kg
Fuel tank6.0 L
Tank runtime3.3 hr

Engine

Cummins/Onan 1.4EGSAA
Oil capacity0.95 L
Coolant capacity0.9 L
Displacement1.4 L
AspirationNatural
Rated speed3600 rpm

Maintenance & consumables

for the Cummins/Onan 1.4EGSAA
ItemSpecCapacityPart #Interval
Air filterAir Filter—100 hr
Fuel filterFuel Filter—100 hr
Oil filterOil Filter—100 hr
BatteryBattery—500 hr
BeltBelt—500 hr
OilEngine Oil—500 hr
Spark plugSpark Plug—100 hr

Common questions

What is the power rating of the Cummins/Onan 1.4 EGSAA?

The Cummins/Onan 1.4 EGSAA is rated 120 kW standby (1400.0 kVA).

What engine is in the Cummins/Onan 1.4 EGSAA?

The Cummins/Onan 1.4 EGSAA is powered by the Cummins/Onan 1.4EGSAA engine.

What fuel does the Cummins/Onan 1.4 EGSAA use?

The Cummins/Onan 1.4 EGSAA runs on Gasoline.

What is the oil capacity of the Cummins/Onan 1.4 EGSAA?

The Cummins/Onan 1.4EGSAA engine in the Cummins/Onan 1.4 EGSAA has an oil capacity of 0.95 liters.

What is the coolant capacity of the Cummins/Onan 1.4 EGSAA?

The Cummins/Onan 1.4 EGSAA cooling system holds 0.95 liters (0.3 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the continuous rating of the Cummins/Onan 1.4 EGSAA?

The Cummins/Onan 1.4 EGSAA is rated 10 kW prime (1200 kVA), against 120 kW standby.

How much does the Cummins/Onan 1.4 EGSAA weigh?

The Cummins/Onan 1.4 EGSAA has a dry weight of 59 kg (130 lb).

How big is the fuel tank on the Cummins/Onan 1.4 EGSAA?

The Cummins/Onan 1.4 EGSAA has a 6 liter (2 US gallon) fuel tank, giving about 3.3 hours of runtime.

What voltages is the Cummins/Onan 1.4 EGSAA available in?

The Cummins/Onan 1.4 EGSAA is offered in 120 V, Single-phase.

How many cold cranking amps does the Cummins/Onan 1.4 EGSAA require?

The Cummins/Onan 1.4 EGSAA uses 1 battery, 12 V each, group 12x5, per the manufacturer specification sheet.

What alternator comes on the Cummins/Onan 1.4 EGSAA?

The Cummins/Onan 1.4 EGSAA uses a 1.4EGSAA alternator. It has 2 poles. Insulation class B.

Troubleshooting

7

Symptoms & remedies

SymptomCauseRemedy
FAILS TO CRANK (ELECTRIC START MODELS)Low Battery, Bad battery connection, Oil is too heavy, Load is connectedCheck battery electrolyte level and charge. Clean and tighten all battery and cable connections. Replace with lighter oil. Always disconnect load while starting.
CRANKS SLOWLY (ELECTRIC START MODELS)Choke closed, Dirty air filter, Rich fuel mixtureOpen choke. Clean or replace air filter. Contact an Onan service center.
ENGINE WONT STARTLoose or worn spark plug lead, Faulty spark plug, Dirty fuel filter or generator set at too steep of an angle, Governor out of adjustment or lean fuel mixCheck spark plug lead connection. Remove and clean or replace spark plug. Check fuel filter and generator set angle. Contact an Onan service center.
EXHAUSTING BLACK SMOKEOpen DC circuit breaker due to an overloadRemove all loads, reset circuit breaker, check for an overload or short circuit. Do not exceed generator set rated load specifications.
UNIT RUNS THEN STOPSAdd fuel. Add oil. Reduce oil level.
UNIT RUNS BUT SURGESAdd fuel. Add oil. Reduce oil level.
NO AC OUTPUT VOLTAGEOpen AC circuit breaker due to an overloadRemove all loads, re-set circuit breaker, check tools or appliances being used for defects. Do not exceed generator set rated load specifications.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

4
Part #DescriptionQtySystem
111-1802Fuel Fill1Fuel Amazon eBay
M-1830-2AC Receptacle1Service part / kit Amazon eBay
M-1833Oil Fill1Service part / kit Amazon eBay
M-18344DC Receptacle1Service part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime100%0.92.5
Standby100%0.82.5

Available documents

Owner's manual — 981-0130 Onan EGH EGS Operator's Manual (2-1994) (Cummins/Onan)