Home›Caterpillar›Caterpillar C18 ACERT

Caterpillar C18 ACERT Generator Set

The Caterpillar C18 ACERT is a 550 kW (600 kVA) diesel standby generator set. It is available at 400 V, 50 Hz.

550 kW
Standby
4
Document types

How to read your Caterpillar serial & model number →

Typical fuel consumption for 550–555 kW Diesel generators →

Compare with other 550–555 kW Diesel generators →

Service parts for the C18 ACERT

Grouped by system, with how many of each the parts manual calls for.

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Fueldiesel
Frequency50.0 Hz
Standby power550 kW
Standby kVA600
Prime power500 kW
EmissionsLow BSFC
Voltage options400 V

Filters & service parts

model family
ItemSpecCapacityPart #Interval
Air filterCat radial seal air filter—750 hr
Fuel filter2 micron high performance—
Oil filter3890434 Amazon eBay $82.42 PartsGeek $30.97 NAPA $45.70
Battery12V, 950 CCA for 30 seconds at -18°C (0°F), 90 amp-hr @ 20 hours, 170 reserve capacity minutes—1000 hr
Coolant—
Oil34.0 L—250 hr

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.

Service intervals

3
ItemActionHoursMonthsNotes
Primary air filter elementChange250 hrWhen changing the primary element at 250 operating hours (basis of the without-indicator filter-change comparison)
engineOther500 hrCat compact diesel lineup offers 500-hour maintenance intervals and single-side service access
Secondary air filter elementChange750 hrWhen changing the secondary element at 750 operating hours (basis of the without-indicator filter-change comparison)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

39
TypeItemValueUnitCondition
OtherAir compressor air flow374L/min (13.2 cfm) @ 1250 rpmC7 ACERT, C9 ACERT
OtherAir compressor air flow445L/min (15.7 cfm) @ 1250 rpmC11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT
OtherAir compressor air flow467L/min (16.5 cfm) @ 1250 rpmC7 ACERT, C9 ACERT
OtherAir compressor air flow889L/min (31.4 cfm) @ 1250 rpmC11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT
OtherArr. Number3149714
OtherBore145.0mm (5.71 in)
OtherCompression ratio16.3:1
OtherDisplacement18.1L (1,104.53 in3)
OtherEmissions certificationU.S. EPA Tier 2 and CARB; FM approved; UL listed - US and Canada; Meets NFPA 20 requirements
OtherEngine dimension (1) Length1889.0mm (74.37 in)Do not use for installation design
OtherEngine dimension (2) Width1091.0mm (42.95 in)Do not use for installation design
OtherEngine dimension (3) Height1379.7mm (54.32 in)Do not use for installation design
OtherFeature CodeC18DF03
OtherGross Input Torque (TH55-E70)12 667N•m (9350 lb-ft)
OtherGross Input Torque (TH55-E90)12 677N•m (9350 lb-ft)
OtherNet dry weight (approximate)1769kg (3900 lb)
OtherPerformance NumberEM0022-01
OtherRadiator cooling package maximum elevation1524m (5000 ft)with 50/50 water/Extended Life Coolant mixture
OtherRating condition (diesel 7 L and higher)99 kPa (29.31 in Hg) dry barometer, 25°C (77°F)SAE J1995 inlet air standard
OtherRating condition (diesel up to 6.6 L)100 kPa (29.5 in Hg) total barometric pressure, 1 kPa (.295 in Hg) vapor pressure, 25°C (77°F)ISO/TR14396 inlet air standard
OtherRating condition (gas)100 kPa (29.61 in Hg) and 25°C (77°F)SAE J1349 standard
OtherRating condition - inlet air standard conditions99 kPa (29.31 in. Hg) dry barometer
OtherStall Torque Ratio (TH55-E70)2.23
OtherStall Torque Ratio (TH55-E90)2.23
OtherStroke183.0mm (7.2 in)
OtherWeight, Net Dry (approximate)1673kg (3688 lb)
OtherWeight, Net Dry (approximate)1769kgapproximate
PressureWS255 pump plunger load238,000lb (107,960 kg)
PressureWS273XD pump plunger load275,000lb (124 738 kg)
PressureWS305XD pump plunger load250,000lb (113 398 kg)
SpeedMaximum Input Speed (TH55-E70/TH55-E90 transmissions)1970rpm
SpeedRated Input Speed (TH55-E70/TH55-E90 transmissions)1900rpm
SpeedRated engine speed2100rpmrated power 597 kW / 800 bhp
SpeedRotation (from flywheel end)Counterclockwise
TemperatureRadiator cooling package design ambient temperature48.9°C (120°F)coolant mixture 50/50 (water/Caterpillar Extended Life Coolant), maximum elevation 1524 m (5000 ft)
TemperatureRating condition - inlet air temperature25degC (77 degF)
TorqueAir compressor SAE "A" hydraulic pump drive maximum torque (374 L/min and 467 L/min compressors)60N•m (44 lb-ft)C7, C9 ACERT
TorqueAir compressor maximum torque (374 L/min / 13.2 cfm @ 1250 rpm, C7/C9)60N·m (44 lb-ft)374 L/min (13.2 cfm) @ 1250 rpm
TorqueAir compressor maximum torque (467 L/min / 16.5 cfm @ 1250 rpm, C7/C9)60N·m (44 lb-ft)467 L/min (16.5 cfm) @ 1250 rpm

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50/50 (water/Caterpillar Extended Life Coolant)below 48°CRadiator cooling packages designed for up to 48.9°C (120°F) ambient up to a maximum elevation of 1524 m (5000 ft)
Coolant50/50 mixture water/Caterpillar Extended Life Coolantbelow 48°CRadiator cooling packages designed for up to 48.9° C (120° F) ambient; coolant sump refill capacities vary by oil sump/pan (18 L to 106 L service refill with new oil filter change)
Engine oilEPA 2D 89.330-96 (fuel reference, Diesel <6.6 L, density 0,845-0,850 kg/L a 15 °C)Reference condition only, not a lubricant recommendation
Engine oillow sulfated ash oilRequired for U.S. EPA Tier 4 Final, EU Stage IV engines.
FuelUltra Low Sulfur Diesel (ULSD)Contains less than or equal to 15 parts per million sulfur (mg/kg); required for U.S. EPA Tier 4 Final, EU Stage IV engines. B20 biodiesel capability available.
Fuel35 API gravityStandard fuel with lower heating value of 42,780 kJ/kg (18,390 btu/lb) when used at 29 C (84.2 F) with a density of 838.9 g/L
Fuel35° API gravity at 60°F (16°C)LHV 18,390 Btu/lb (42 780 kJ/kg)Fuel at 85°F (29°C) weighing 7.001 lbs/U.S. gal (838.9 g/liter)
Fuel35° API gravity, LHV 42 780 kJ/kg (18,390 btu/lb)SAE J1995Diesel engines 7 liter and higher; used at 29°C (84.2°F) with density 838.9 g/L
FuelEPA 2D 89.330-96EPA 2D 89.330-96Diesel engines up to 6.6 liter; density 0.845-0.850 kg/L @ 15°C (59°F); fuel inlet temperature 40°C (104°F)
Fueldry natural gas, LHV 35.54 MJ/Nm3 (905 btu/ft3)Gas ratings based on SAE J1349 standard conditions of 100 kPa (29.61 in Hg) and 25°C (77°F)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the Caterpillar C18 ACERT?

The Caterpillar C18 ACERT is rated 550 kW standby (600.0 kVA).

Is the Caterpillar C18 ACERT diesel or gas?

The Caterpillar C18 ACERT runs on diesel.

What is the prime power rating of the Caterpillar C18 ACERT?

The Caterpillar C18 ACERT is rated 500 kW prime (545 kVA), against 550 kW standby.

What voltages is the Caterpillar C18 ACERT available in?

The Caterpillar C18 ACERT is offered in 400 V.

Which oil filter part number does the Caterpillar C18 ACERT take?

The Caterpillar C18 ACERT uses oil filter part number 3890434.

Available documents

Engine spec — C18+-+Dry+-+LEHW0053-00+P4 (Caterpillar)Engine spec — C18DF02 522 BKW 700 BHP 1750 RPM (Caterpillar)Engine spec — C18 ACERT 429 bkW 575 bhp (Caterpillar)Engine spec — C18 ACERT 429bkW (Caterpillar)Engine spec — C18 ACERT 448 bkW 600 bhp (Caterpillar)Engine spec — C18 ACERT 470bkW (Caterpillar)Engine spec — C18 ACERT 522bkW (Caterpillar)Engine spec — C18 ACERT 571bkW (Caterpillar)Engine spec — C18 ACERT 597bkW (Caterpillar)Engine spec — C18 FIRE PUMP 448 BKW 600 BHP 1750 RPM (Caterpillar)Engine spec — C18 FIRE PUMP 448 BKW 600 BHP 1900 RPM (Caterpillar)Engine spec — C18 FIRE PUMP 448 BKW 600 BHP 2100 RPM (Caterpillar)Engine spec — C18 FIRE PUMP 522 BKW 700 BHP 1500 RPM (Caterpillar)Engine spec — C18 FIRE PUMP 522 BKW 700 BHP 1900 RPM (Caterpillar)Engine spec — C18 FIRE PUMP 522 BKW 700 BHP 2100 RPM (Caterpillar)Engine spec — C18 FIRE PUMP 597 BKW 800 BHP 1750 RPM (Caterpillar)Engine spec — C18 FIRE PUMP 597 BKW 800 BHP 1900 RPM (Caterpillar)Engine spec — C18 FIRE PUMP 597 BKW 800 BHP 2100 RPM (Caterpillar)Engine spec — C18 higher acert ind18 (Caterpillar)Engine spec — CAT-C18-755HP-T4i (Caterpillar)Engine spec — LECH3874-07 (Caterpillar)Engine spec — LEGH0001-02 (Caterpillar)Engine spec — LEGH0001-03 (Caterpillar)Engine spec — LFDH5502-01 HR (Caterpillar)Engine spec — YEGT3002 (Caterpillar)Engine spec — lech3874-04 (Caterpillar)Engine spec — lecw2462-06 (Caterpillar)Spec sheet — SAEDC18-625 (Caterpillar)Spec sheet — SAEDC18-700 (Caterpillar)Reference — Aug+2010+Engine+Selection+Guide (Caterpillar)Reference — Cat-Marine-Engine-Selection-Guide-LEDM3457-21 (Caterpillar)Reference — Caterpillar-Oil-and-Gas-Ratings-Guide-2021-03 (Caterpillar)Reference — Final+Ratings+Guide LECW2462-15 9.8.11 (Caterpillar)Reference — Industrial rating guide (Caterpillar)Reference — LECW2462-01 (Caterpillar)Reference — LECW2462-25 1 oil gas (Caterpillar)Reference — LEDH6161-02 (Caterpillar)Reference — LEDH7559 (Caterpillar)Reference — LEGH0002 (Caterpillar)Reference — Ratings Guide Port LPCW2462-15 final LR (Caterpillar)Reference — ledh6161 attachments guide (Caterpillar)Parts manual — LEXE7582-02 (Caterpillar)

This page was generated from the 42 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Oil filter 3890434$30.97