Home›AKSA›AKSA AD600

AKSA AD600 Generator Set

The AKSA AD600 is a 600 kW (750 kVA) Diesel standby generator set powered by a Perkins 2506A-E15TAG3 engine. It is available at 400/230 V, 208/120 V, 480/277 V and 600/347 V, 3-phase and 50 Hz. It holds about 62 L (16.4 gal) of oil and 58 L (15.3 gal) of coolant, with a maximum ambient rating of 40 °C. The set measures 3500×1200×2000 mm (137.8×47.2×78.7 in), weighs about 2200 kg (4850 lb) and produces 65 dBA at 7 m. An integrated tank holds 100 L (26.4 gal), roughly 10 hours of runtime. The same 2506A-E15TAG3 engine also powers generator sets from FG Wilson.

600 kW
Standby
15.2 L
Displacement
62.0 L
Oil capacity
1
Document types

Typical fuel consumption for 600–605 kW Diesel generators →

Compare with other 600–605 kW Diesel generators →

Specifications

FuelDiesel
Frequency50.0 Hz
Standby power600 kW
Standby kVA750
Prime power545 kW
Oil capacity62.0 L
AlternatorMecc Alte ECP3-4S/4
Voltage options400/230 V, 208/120 V, 480/277 V, 600/347 V
Phase3
Power factor0.8
Max ambient40 °C
Dimensions (L×W×H)3500×1200×2000 mm
Dry weight2200 kg
Sound level65.0 dBA @ 7 m
Fuel tank100.0 L
Tank runtime10 hr

Engine

Perkins 2506A-E15TAG3
Oil capacity62.0 L
Coolant capacity58.0 L
Displacement15.2 L
AspirationTurbocharged and air-to-air charge cooled
Rated speed1500 rpm

Filters for the Perkins 2506A-E15TAG3

2

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

SystemFilterDescriptionCross-references
Oil filterP551808Lube Filter, Spin-On Full FlowPERKINS 4587260, NAPA 7792, BALDWIN B7299, CLAAS 0000900651 KuduParts $80.00
Fuel filterP551311Fuel Filter, Spin-On SecondaryPERKINS 4650996, BALDWIN BF7587, TAMROCK 019854051, LOESING 025133 KuduParts $147.00 FridayParts $151.84

Same engine, other brands

1 brand

The Perkins 2506A-E15TAG3 in this set also powers 2 generator sets sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
FG WilsonP513P1, P563E1

Common questions

How many kW is the AKSA AD600?

The AKSA AD600 is rated 600 kW standby (750.0 kVA).

What engine does the AKSA AD600 use?

The AKSA AD600 is powered by the Perkins 2506A-E15TAG3 engine.

What fuel does the AKSA AD600 use?

The AKSA AD600 runs on Diesel.

What is the oil capacity of the AKSA AD600?

The Perkins 2506A-E15TAG3 engine in the AKSA AD600 has an oil capacity of 62.0 liters.

What is the coolant capacity of the AKSA AD600?

The AKSA AD600 cooling system holds 58 liters (15.3 US gallons) for the engine, per the manufacturer specification sheet.

What is the continuous rating of the AKSA AD600?

The AKSA AD600 is rated 545 kW prime (681 kVA), against 600 kW standby.

How loud is the AKSA AD600?

The AKSA AD600 is rated at 65.0 dBA at 7 m, per the manufacturer specification sheet.

What is the dry weight of the AKSA AD600?

The AKSA AD600 has a dry weight of 2200 kg (4850 lb).

How big is the fuel tank on the AKSA AD600?

The AKSA AD600 has a 100 liter (26 US gallon) fuel tank, giving about 10 hours of runtime.

What voltages is the AKSA AD600 available in?

The AKSA AD600 is offered in 400/230 V, 208/120 V, 480/277 V, 600/347 V, 3-phase.

What alternator does the AKSA AD600 use?

The AKSA AD600 uses a Mecc Alte ECP3-4S/4 alternator.

Available documents

Spec sheet — Aksa GlobalPerformans FR (AKSA)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Other sets with this engine