Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 600 kW |
| Standby kVA | 750 |
| Prime power | 545 kW |
| Oil capacity | 62.0 L |
| Alternator | Mecc Alte ECP3-4S/4 |
| Voltage options | 400/230 V, 208/120 V, 480/277 V, 600/347 V |
| Phase | 3 |
| Power factor | 0.8 |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 3500×1200×2000 mm |
| Dry weight | 2200 kg |
| Sound level | 65.0 dBA @ 7 m |
| Fuel tank | 100.0 L |
| Tank runtime | 10 hr |
Engine
| Oil capacity | 62.0 L |
|---|---|
| Coolant capacity | 58.0 L |
| Displacement | 15.2 L |
| Aspiration | Turbocharged and air-to-air charge cooled |
| Rated speed | 1500 rpm |
Filters for the Perkins 2506A-E15TAG3
2Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P551808 | Lube Filter, Spin-On Full Flow | PERKINS 4587260, NAPA 7792, BALDWIN B7299, CLAAS 0000900651 | KuduParts $80.00 |
| Fuel filter | P551311 | Fuel Filter, Spin-On Secondary | PERKINS 4650996, BALDWIN BF7587, TAMROCK 019854051, LOESING 025133 | KuduParts $147.00 FridayParts $151.84 |
Same engine, other brands
1 brandThe Perkins 2506A-E15TAG3 in this set also powers 2 generator sets sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| FG Wilson | P513P1, P563E1 |
Common questions
How many kW is the AKSA AD600?
The AKSA AD600 is rated 600 kW standby (750.0 kVA).
What engine does the AKSA AD600 use?
The AKSA AD600 is powered by the Perkins 2506A-E15TAG3 engine.
What fuel does the AKSA AD600 use?
The AKSA AD600 runs on Diesel.
What is the oil capacity of the AKSA AD600?
The Perkins 2506A-E15TAG3 engine in the AKSA AD600 has an oil capacity of 62.0 liters.
What is the coolant capacity of the AKSA AD600?
The AKSA AD600 cooling system holds 58 liters (15.3 US gallons) for the engine, per the manufacturer specification sheet.
What is the continuous rating of the AKSA AD600?
The AKSA AD600 is rated 545 kW prime (681 kVA), against 600 kW standby.
How loud is the AKSA AD600?
The AKSA AD600 is rated at 65.0 dBA at 7 m, per the manufacturer specification sheet.
What is the dry weight of the AKSA AD600?
The AKSA AD600 has a dry weight of 2200 kg (4850 lb).
How big is the fuel tank on the AKSA AD600?
The AKSA AD600 has a 100 liter (26 US gallon) fuel tank, giving about 10 hours of runtime.
What voltages is the AKSA AD600 available in?
The AKSA AD600 is offered in 400/230 V, 208/120 V, 480/277 V, 600/347 V, 3-phase.
What alternator does the AKSA AD600 use?
The AKSA AD600 uses a Mecc Alte ECP3-4S/4 alternator.
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.