Yanmar 3TNV84T Engine
The Yanmar 3TNV84T is a 1.5 L 3-cylinder turbocharged engine rated at 1300 rpm, producing up to 30.1 kW. It powers generator sets from Kohler, including the 12.5EFORZD. It holds 1.5 L (0.4 gal) of oil and 1.5 L (0.4 gal) of coolant.
Also known as: Yanmar 3TNV84T
Part of the Yanmar 3TNV84T engine family — 2 variants share parts & fitment.
Engine specifications
| Oil capacity | 1.5 L |
|---|
| Coolant capacity | 1.5 L |
|---|
| Displacement | 1.496 L |
|---|
| Cylinders | 3 |
|---|
| Aspiration | Turbocharged |
|---|
| Rated speed | 1300 rpm |
|---|
| Gross power | 30 kW |
|---|
Maintenance schedule
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Fault codes
2| Code | Name | Meaning | Severity | Action |
|---|
| CO-3 | | Fault displayed if the CO parameter is set incorrectly | Shutdown | |
| CO-6 | | Fault displayed if the CO parameter is set incorrectly | Shutdown | |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
3Controller Configuration adjustment
⚠ Be sure to save the new settings immediately before exiting the configuration mode; changes are lost if the controller times out (about 1 minute).
- Hold the Select button and move the master switch to RUN to enter configuration mode.
- Press the down arrow key then the up arrow key 3 times to enter configuration mode (password).
- Set the voltage/frequency parameter Uu for the model.
- Set the unit configuration parameter Uc (marine, standby, mobile).
- Set the engine type parameter Ec.
- Press the up arrow at the Adnc display to enter advanced configuration mode.
- Set the engine data input type Ed.
- Set the battery voltage Bt (12 or 24 VDC).
- Set the communications parameter Cn.
- Enter save mode and save your settings before exiting.
Output Voltage and Frequency Adjustment adjustment
⚠ The generator set must be running during these adjustments.
⚠ The engine speed (frequency) adjustment menus are not accessible on models with mechanical governors.
Tools: multimeter
- Move the master switch to RUN; the engine starts and runtime hours display.
- Hold the Select button about 5 seconds until the program version number displays.
- Press the down arrow key then the up arrow key 3 times to enter adjustment mode.
- 1P: adjust voltage coarse in large increments (approximately 5-7 volts per step).
- 2P: adjust voltage fine in smaller increments (approximately 0.5-0.7 volts per step).
- Adjust voltage stability (gain) coarse and fine.
- 3P: set volts/Hz (00=low, 09=high).
- 4P: adjust engine governor speed coarse and fine.
- 5P: adjust engine governor stability (gain) coarse and fine.
- Enter SAVE mode and save settings before exiting the adjustment mode.
Controller Replacement installation
⚠ Disconnect the battery cables before working on the generator set; remove the negative lead first and reconnect it last.
Tools: multimeter, personal computer with Program Loader Software
- Record generator set information required for configuration: model, market, voltage, frequency, phases, battery voltage.
- Place the generator set master switch in the OFF position.
- Disconnect power to the battery charger, if equipped.
- Disconnect the engine starting battery(ies), negative lead first.
- Open the junction box; disconnect the controller at P1, J15, and J16.
- Models ECD/EFCD, EGD/EFGD, EGZD only: disconnect the CO sensor harness at the 4-pin connector.
- Remove four controller mounting screws and remove the old controller.
- ECD/EFCD, EGD/EFGD, EGZD only: install CO sensor module assembly GM46362 on the back of the new controller GM47982.
- Install the new controller and secure with the mounting screws.
- Reconnect the P1, J15, and J16 connectors; connect the CO sensor harness on applicable models.
- Models 10/13/15EG, 10/13/15ERG, 15/30RES, 15/30RYG with S/N before 2053692: cut a 1-in. section of the gray/orange lead entering pin 9 at the ECM connector.
- Check that the generator set master switch is in the OFF position.
- Reconnect the engine starting battery, negative lead last.
- Reconnect power to the battery charger, if equipped.
- Check the controller application software version and load the latest application code if necessary.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|
| 100 VAC | 1 | 1Ph, 2W | | Uu00; 60 Hz |
| 100 VAC | 1 | 1Ph, 3W | | Uu00; 60 Hz |
| 100/200 VAC | 1 | 1Ph, 3W | | Uu08; 60 Hz |
| 110 VAC | 1 | 1Ph, 2W | | Uu05; 50 Hz |
| 110 VAC | 1 | 1Ph, 3W | | Uu05; 50 Hz |
| 110/190 VAC | 3 | Wye | | Uu17; 50 Hz |
| 110/220 VAC | 1 | 1Ph, 3W | | Uu07; 50 Hz |
| 110/220 VAC | 1 | Dogleg | | Uu07; 50 Hz |
| 110/220 VAC | 3 | Delta | | Uu15; 50 Hz |
| 115 VAC | 1 | 1Ph, 2W | | Uu05; 50 Hz |
| 115/200 VAC | 3 | Wye | | Uu23; 50 Hz |
| 115/230 VAC | 1 | 1Ph, 3W | | Uu02; 50 Hz |
| 115/230 VAC | 1 | Dogleg | | Uu06; 50 Hz |
| 115/230 VAC | 3 | Delta | | Uu14; 50 Hz |
| 120 VAC | 1 | 1Ph, 2W | | Uu00; 60 Hz |
| 120 VAC | 1 | 1Ph, 3W | | Uu00; 60 Hz |
| 120/208 VAC | 3 | Wye | | Uu11; 60 Hz |
| 120/240 VAC | 1 | 1Ph, 3W | | Uu01; 60 Hz |
| 120/240 VAC | 1 | Dogleg | | Uu01; 60 Hz |
| 120/240 VAC | 3 | Delta | | Uu10; 60 Hz |
| 127/220 VAC | 3 | Wye | | Uu16; 60 Hz |
| 139/240 VAC | 3 | Wye | | Uu10; 60 Hz |
| 220 VAC | 1 | 1Ph, 2W | | Uu12; 50 Hz |
| 220/380 VAC | 3 | Wye | | Uu19; 60 Hz |
| 230 VAC | 1 | 1Ph, 2W | | Uu02; 50 Hz |
| 230/400 VAC | 3 | Wye | | Uu03; 50 Hz |
| 240 VAC | 1 | 1Ph, 2W | | Uu13; 50 Hz |
| 240/416 VAC | 3 | Wye | | Uu20; 60 Hz |
| 277/480 VAC | 3 | Wye | | Uu04; 60 Hz |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Parts cataloged across the Yanmar 3TNV84T family
29Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
Aftermarket parts that fit this engine
60Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.
Also used in
7- John Deere 2036R — Tractor
- John Deere 3039R — Tractor
- John Deere 3203 — Tractor
- John Deere 3520 — Tractor
- John Deere 3720 — Tractor
- John Deere 4105 — Tractor
- Weidemann T4512CC40 — Telehandler
Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.
Common questions
What is the oil capacity of the Yanmar 3TNV84T?
The Yanmar 3TNV84T engine has an oil capacity of 1.5 liters.
What is the displacement of the Yanmar 3TNV84T?
The Yanmar 3TNV84T has a displacement of 1.496 liters with 3 cylinders.
Which generators use the Yanmar 3TNV84T engine?