HomeEnginesVolvo Penta TWD1683GE

Volvo Penta TWD1683GE Engine

The Volvo Penta TWD1683GE is a 16.12 L 6-cylinder dual stage turbochargers with intermediate charge air coolers engine rated at 1500 rpm, producing up to 596 kW. It powers generator sets from Generac and Volvo Penta, including the MDE1450 TwinGen.

Also known as: Volvo Penta TWD1683GE

16.12 L
Displacement
6
Cylinders
1500 rpm
Rated speed
596 kW
Gross power

Engine specifications

Displacement16.12 L
Cylinders6
AspirationDual stage turbochargers with intermediate charge air coolers
Rated speed1500 rpm
Gross power596 kW

Generator sets powered by this engine

2

Shared across brands: Generac, Volvo Penta

Generac MDE1450 TwinGenVolvo Penta TWD1683GE

How to read your Volvo Penta engine serial & model number →

Common problems

7
  • Vibrations
    Fix: The machine does not produce vibrations of considerable intensity. The engine can generate localized vibrations (see engine manual). The machine may suffer vibrations caused by any nearby sources in the installation area.
  • The load-bearing frame of the machine must be properly connected to the grounding system.
    Fix: Static Electricity: Measures taken / recommendations: Mechanical design has avoided all situations that can generate accumulations of electrostatic charges. That phenomenon cannot be completely eliminated (even simple ventilation, in particular environmental conditions, can generate electrostatic charges). It is therefore appropriate to provide adequate connections to the grounding system in accordance with the procedures laid down in the relevant harmonized standards. The position of the connection points is indicated in the technical documentation supplied with the machine.
  • Overheating of the External Surfaces of the Engine and/or Other Machine Parts
    Fix: The engine and other machine parts may overheat until exceeding the danger threshold. THE OPERATOR WHO HAS TO TOUCH CERTAIN MACHINE PARTS MUST MAKE SURE IN ADVANCE THAT THE TEMPERATURE OF SURFACES IS NOT HIGHER THAN THE DANGER THRESHOLD. IF HIGHER, THE OPERATOR MUST CAUTION
  • Noise
    Fix: The noise of the machine depends essentially on the type of engine applied. Carefully read the values indicated in the engine documentation (Declaration of Conformity, CE plate, data card). The emitted sound pressure also depends on possible resonance phenomena related to the installation environment. Therefore, it is recommended to perform new general noise tests on the machine at the installation site. If the values exceed 84 dB, it is mandatory to use appropriate PPE for hearing protection.
  • Fuel and/or Ad Blue/DEF Refilling
    Fix: This operation is particularly risky (also due of its high frequency compared to other use and maintenance operations). The fuel and/or AdBlue/DEF refilling must be performed as follows: With all electrical appliances disconnected (on alternator side). With the combustion engine switched off and stopped. Only if the temperature of the engine surfaces near the fuel and/or AdBlue/DEF refilling point is lower than 50 °C.
  • Errors of Fitting
    Fix: Instructions for use and maintenance, assembly and dismantling, detailed and described with technical drawings and trigonometric projections. Technical assistance and on line documentation available for each market area.
  • Engine Operations
    Fix: All operations on the engine, including fuel and/or Ad Blue/DEF refueling operations, can create a risk of leakage of fuel and/or Ad Blue/DEF and/or lubricating oil. Contact with fuel and/or Ad Blue/DEF or synthetic oils can cause dermatitis, irritation, loss of visibility, loss of consciousness and symptoms of asphyxia and panic. THE OPERATOR MUST WEAR ADEQUATE PPE TO THE OPERATION BEING PERFORMED. IF THE ACTIVITY OCCURS IN “CONFINED SPACES”, ALL RELEVANT PROCEDURES MUST BE ADOPTED AND RESPECTED.

Compiled from service & troubleshooting documentation across every generator set that uses the Volvo Penta TWD1683GE.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterReplacement3650 hr
Fuel filter5 micron Double Fuel Pre-filter with water separator12000 hr
Oil filter40 micron12000 hr
Battery975 CCA, 12 (4) V (Qty)1000 hr
Belt143650 hr
Coolant1000 hr
Coolant filterRevolving
OilGear type lubricating oil pump, gear driven by the transmission50.0 qt (L)500 hr
Spark plugUnit Injector Delphi12000 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Common questions

What is the displacement of the Volvo Penta TWD1683GE?

The Volvo Penta TWD1683GE has a displacement of 16.12 liters with 6 cylinders.

Which generators use the Volvo Penta TWD1683GE engine?

The Volvo Penta TWD1683GE powers 2 generator set(s), including Generac MDE1450 TwinGen, Volvo Penta TWD1683GE.

How often should you change the oil in the Volvo Penta TWD1683GE?

The Volvo Penta TWD1683GE oil change interval is every 500 hours.

What is a common problem with the Volvo Penta TWD1683GE engine?

A commonly reported issue on generators using the Volvo Penta TWD1683GE is: Vibrations. Fix: The machine does not produce vibrations of considerable intensity. The engine can generate localized vibrations (see engine manual). The machine may suffer vibrations caused by any nearby sources in the installation area..