Home›Engines›Perkins 1204F-E44TTA

Perkins 1204F-E44TTA Engine

The Perkins 1204F-E44TTA is a 4.4 L 4-cylinder engine rated at 2200 rpm, producing up to 112 kW. It powers generator sets from Generac, including the MFH900.

Also known as: Perkins 1204F-E44TTA

Part of the Perkins 1204F engine family — 2 variants share parts & fitment.

4.4 L
Displacement
4
Cylinders
2200 rpm
Rated speed
112 kW
Gross power

Service parts for the 1204F-E44TTA

The cheapest captured merchant offer per filter — see the full cross-reference below for every OEM/aftermarket option.

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Verify against your serial number before ordering.

Engine specifications

Displacement4.4 L
Cylinders4
Rated speed2200 rpm
Gross power112 kW

Generator sets powered by this engine

1
Generac MFH900

How to read your Perkins engine serial & model number →

Troubleshooting

2

Symptoms & remedies

SymptomRemedy
If a fault becomes active turn off the engine.If the application as a battery disconnect lamp installed, the DEF system will be purged after the battery disconnect lamp is extinguished. If no battery disconnect lamp is installed, allow 10 minutes or 15 minutes if the system has a DPF for the DEF system to purge. Then restart the engine.
If the fault continues to stay active.Refer to Troubleshooting for more information.

Fault codes and symptom→remedy steps extracted from this engine’s service/owner documentation; verify against the official manual before servicing.

Common problems

15
  • Engine cranks but does not start
    Cause: No fuel
    Fix: Verify there is no fuel leakage and replenish.
  • Engine has no power
    Cause: Clogged air cleaner
    Fix: Clean element.
  • Engine starts but stops shortly thereafter
    Cause: Low idle
    Fix: Adjust by idling control equipment on the machine. If adjustment is not possible, contact ISUZU dealer.
  • Overheat/shutdown condition
    Cause: Access doors are open
    Fix: Close all access doors.
  • No/low heat condition
    Cause: Incorrect heater setting (target temperature too low)
    Fix: Adjust heater output.
  • Exhaust smoke is black
    Cause: Excessive speed
    Fix: Verify engine RPM. Check AVR adjustment.
  • Engine overheats
    Cause: No coolant
    Fix: Add coolant.
  • Exhaust smoke is white
    Cause: Insufficient warm-up time
    Fix: Conduct warm-up operation.
  • Engine does not crank
    Cause: Discharged battery
    Fix: Replace battery.
  • Oil pressure does not rise
    Cause: Incorrect engine oil viscosity
    Fix: Change with oil of correct viscosity.
  • Engine running is unstable
    Cause: Fuel system failure
  • Water In Fuel — Water detected in fuel Water In Fuel
  • Service Due — Service is due for one or more of: Engine oil; Air filter; Engine fuel filter; Hydraulic oil filters Service Due
    Fix: See Draining Fluids—Union Fluid Drain.
  • Regen Inhibit — Control system not allowing high idle that engine has requested Regen Inhibit
  • Low Diesel Fuel — Steady ON (amber): Fuel level is 20%; Slow flash (red): Fuel level is 16%; Fast flash (red): Fuel level is 12% or below Low Diesel Fuel

Compiled from service & troubleshooting documentation across every generator set that uses the Perkins 1204F-E44TTA.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterGenuine Generac parts are recommended for all maintenance items. All Generac oil kits meet minimum American Petroleum Institute (API) Service Class CJ-4/SM.—500 hr
Fuel filterGenuine Generac parts are recommended for all maintenance items. All Generac oil kits meet minimum American Petroleum Institute (API) Service Class CJ-4/SM.—250 hr
Oil filterGenuine Generac parts are recommended for all maintenance items. All Generac oil kits meet minimum American Petroleum Institute (API) Service Class CJ-4/SM.2654A111500 hr Amazon eBay $23.99 NAPA $22.21 FridayParts $28.06 KuduParts $48.00
BatteryBattery—Rating: CCA 950; Battery—Group Number: 31; Battery—Voltage (Quantity Per Unit): 12 (2); Battery—Quantity: 2.—500 hr
Belt—1000 hr
CoolantWhere the atmospheric temperature falls below freezing, the cooling system should be drained after engine operation. To eliminate the need for repeated draining and refilling, the use of a 50/50 Ethylene glycol base antifreeze/water mix is recommended. Never exceed a 60/40 antifreeze/water mix.—
Coolant filtergauges/replace HTF filters—
OilGenuine Generac parts are recommended for all maintenance items. All Generac oil kits meet minimum American Petroleum Institute (API) Service Class CJ-4/SM.—4000 hr
Spark plug—

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Aftermarket parts that fit this engine

23

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Filters for this engine

  • Oil filter: Perkins 2654A111 Donaldson P550920 Wix 57325 Baldwin B7378

Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.

Also used in

1
  • Doosan DX140LCR-5 — Excavator Tracked

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the displacement of the Perkins 1204F-E44TTA?

The Perkins 1204F-E44TTA has a displacement of 4.4 liters with 4 cylinders.

Which generators use the Perkins 1204F-E44TTA engine?

The Perkins 1204F-E44TTA powers 1 generator set(s), including Generac MFH900.

What oil filter does the Perkins 1204F-E44TTA use?

The Perkins 1204F-E44TTA uses oil filter part numbers Perkins 2654A111, Donaldson P550920, Wix 57325.

How often should you change the oil in the Perkins 1204F-E44TTA?

The Perkins 1204F-E44TTA oil change interval is every 4000 hours.

What is a common problem with the Perkins 1204F-E44TTA engine?

A commonly reported issue on generators using the Perkins 1204F-E44TTA is: Engine cranks but does not start. Cause: No fuel. Fix: Verify there is no fuel leakage and replenish..