The Kubota V2403M is a 2.43 L 4-cylinder natural engine rated at 1600 rpm, producing up to 18.5 kW. It powers generator sets from Cummins/Onan, including the MDKB. It holds 7.6 L (2.0 gal) of oil and 7.6 L (2.0 gal) of coolant.
Also known as: Kubota V2403M
Part of the Kubota V2403M engine family — 7 variants share parts & fitment.
| Oil capacity | 7.6 L |
|---|---|
| Coolant capacity | 7.6 L |
| Displacement | 2.434 L |
| Cylinders | 4 |
| Aspiration | natural |
| Rated speed | 1600 rpm |
| Gross power | 18 kW |
Compiled from service & troubleshooting documentation across every generator set that uses the Kubota V2403M.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Check Engine Oil Level | Check | 8 hr | ||
| Coolant Level | Check | 8 hr | Before first startup of each day. | |
| Drain Water from Fuel Filter | Drain | 8 hr | ||
| Engine oil level | Check | 8 hr | Every Day/8 Hrs (Table 4-1) | |
| Exhaust system | Inspect | 8 hr | Look over entire exhaust system and listen for leaks every startup and after every eight hours of operation | |
| Fuel Filter | Drain | 8 hr | ||
| Fuel Filter Water | Drain | 8 hr | ||
| General Inspection | Check | 8 hr | Daily, 8-Hr; includes Oil Level, Coolant Level, Fuel System, Exhaust System, Battery, and Sea Water Strainer Checks. | |
| General Inspection | Inspect | 8 hr | Includes inspection of oil level, coolant level, fuel system, exhaust system, batteries and battery connections; before first start of day and after every 8 hours | |
| General Inspection (Oil Level, Coolant Level, Fuel System, Exhaust System, Battery, Sea Water Strainer) | Check | 8 hr | Every day, all models (MDKBH, MDKBJ, MDKBW, MDKB & MDKD, MDDCX) | |
| General Inspection (oil, coolant, fuel, exhaust, batteries) | Inspect | 8 hr | every day / before first start of the day | |
| Generator Set | Inspect | 8 hr | General Inspection; includes oil level, coolant level, fuel system, exhaust system, batteries and sea water strainer. | |
| Sea Water Strainer | Clean | 8 hr | Clean if necessary and make sure sea cock is open. | |
| Change Engine Oil and Oil Filter - All except MDKBT & MDKBU | Change | 50 hr | First service — after first 50 hrs, then every 200 hrs/year | |
| Change Engine Oil and Oil Filter - Only MDKBT & MDKBU | Change | 50 hr | First service — after first 50 hrs, then every 200 hrs/year | |
| Engine Oil and Oil Filter (All except MDKBT & MDKBU) - after first 50 hours | Change | 50 hr | First service — Break-in oil change; also change the oil and oil filter after the first 50 hours of operation on a new or re-built engine. | |
| Engine Oil and Oil Filter (Only MDKBT & MDKBU) - after first 50 hours | Change | 50 hr | First service | |
| Engine oil and oil filter - all except MDKBT & MDKBU | Change | 50 hr | First service — After first 50 hours of operation; then per Table 4-1 | |
| Engine oil and oil filter - only MDKBT & MDKBU | Change | 50 hr | First service — After first 50 hours of operation; then per Table 4-1 | |
| Battery | Check | 100 hr | 1 mo | See battery manufacturer's recommendations. |
| Battery and Battery Connections | Inspect | 100 hr | 1 mo | See battery manufacturer's recommendations. |
| Check V-Belt Tension | Check | 100 hr | check for slippage, cracking and wear | |
| Engine Oil and Oil Filter (All except MDKBT & MDKBU) | Change | 100 hr | 1 mo | First service — Perform twice as often when using high sulfur fuel. |
| Fuel Filters | Drain | 100 hr | 1 mo | Every Month / 100 Hrs |
| Inspect Battery and Battery Connections | Inspect | 100 hr | monthly | |
| Siphon Break | Check | 500 hr | 12 mo | Monthly, 100-Hr |
| Siphon Break | Inspect | 100 hr | 1 mo | Every Month / 100 Hrs |
| Water from Fuel Filter | Drain | 100 hr | 1 mo | Every Month/100 Hrs |
| Water in Fuel | Drain | 100 hr | Every Month/100 Hrs; drain more often if fuel quality is poor or condensation cannot be avoided | |
| Water in Fuel Filter | Drain | 100 hr | Every Month / 100 Hrs | |
| Zinc Anode | Inspect | 500 hr | 1 mo | Replace as recommended. |
| Zinc Anode | Replace | 500 hr | 12 mo | Monthly, 100-Hr; Model MDKAU does not have a zinc anode to replace. |
| Brushes & Slip Rings | Check | 200 hr | Yearly, 200 Hrs (MDKBH, MDKBJ, MDKBW only); must be performed by trained mechanic; not applicable to other listed models (—) | |
| Engine Oil and Oil Filter | Change | 200 hr | 12 mo | First service — Every Year/200 Hrs |
| Engine Oil and Oil Filter (Only MDKBT & MDKBU) | Change | 200 hr | 12 mo | First service — Perform twice as often when using high sulfur fuel. |
| Engine Oil and Oil Filter—All except MDKBT & MDKBU | Change | 200 hr | First service — After first 50 hrs, then every year/200 hrs | |
| Engine Oil/Oil Filter | Change | 200 hr | 12 mo | First service — Every year/200 hours. |
| Fuel Filters | Replace | 500 hr | 12 mo | Replace fuel filters if the engine lacks power. |
| Inspect Siphon Break | Inspect | 200 hr | yearly | |
| Oil & Oil Filter | Change | 200 hr | 12 mo | First service — Every Year/200 Hrs |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | V-Belt Tension Deflection | 0.4 | inch (10 mm) @ 20 lbs (10 kg) | |
| Clearance | V-belt deflection | 0.4 inch (10 mm) | inch (mm) | 20 lbs (10 kg) applied to middle of pulley span |
| Clearance | V-belt deflection | 3/8 | inch (10 mm) at 20 lbs (10 kg) applied | |
| Clearance | V-belt deflection at 20 lbs (10 kg) | 3/8 inch (10 mm) | in (mm) | tension check at middle of pulley span |
| Clearance | V-belt deflection at middle of pulley span | 3/8 inch (10 mm) | with 20 lbs (10 kg) applied | |
| Clearance | Valve Lash (cold) - D1105/V1505/V2003M/V2403M | 0.0071-0.0087 | in (0.18-0.22 mm) | cold |
| Clearance | Valve Lash (cold) - V3300-E2B | 0.009-0.010 | in (0.23-0.27 mm) | cold |
| Compression | Compression Ratio (MDKAV/MDKAW/MDKAZ) | 22:1 | ||
| Compression | Compression Ratio (MDKBD/MDKBE/MDKBF) | 23:1 | ||
| Gap | V-belt deflection | 0.4 | inch (10 mm) | 20 pounds (10 kg) applied to middle of pulley span |
| Injection timing | Fuel Injection Timing | 12 deg BTDC | deg BTDC | |
| Injection timing | Fuel Injection Timing | 13.5-15 deg BTDC | deg BTDC | |
| Injection timing | Fuel Injection Timing | 14.25-15.75 deg BTDC | deg BTDC | |
| Injection timing | Fuel Injection Timing | 14.75-16.25 deg BTDC | deg BTDC | |
| Injection timing | Fuel Injection Timing | 15.5 - 17.5 | ° BTDC | |
| Injection timing | Fuel Injection Timing | 18.25 − 19.75 | ° BTDC | |
| Injection timing | Fuel Injection Timing | 18° – 20° | BTDC | |
| Injection timing | Fuel Injection Timing - D1105 | 14.75-16.25 | ° BTDC | |
| Injection timing | Fuel Injection Timing - V1505 | 14.25-15.75 | ° BTDC | |
| Injection timing | Fuel Injection Timing - V2003M | 13.5-15 | ° BTDC | |
| Injection timing | Fuel Injection Timing - V2403M | 13.5-15 | ° BTDC | |
| Injection timing | Fuel Injection Timing - V3300-E2B | 12 | ° BTDC | |
| Injection timing | Fuel injection timing | 12 | degrees BTDC | |
| Injection timing | Fuel injection timing | 14.5 | degrees BTDC | |
| Injection timing | Fuel injection timing | 15.5 - 17.5 degrees BTDC | degrees BTDC | |
| Injection timing | Fuel injection timing | 16 | degrees BTDC | |
| Injection timing | Fuel injection timing | 16.5 | degrees BTDC | |
| Injection timing | Fuel injection timing | 18 - 20 | degrees BTDC | timing marks line up at 19 degrees BTDC |
| Other | Battery Charging Output | Trickle (3 amps) | ||
| Other | Battery cable gauge | 1 | AWG | total cable length 22 ft (6.7 m); approx. diameter 9.43 mm |
| Other | Battery cable gauge | 1/0 | AWG | total cable length 30 ft (9.1 m); approx. diameter 9.46 mm |
| Other | Battery cable gauge | 2 | AWG | total cable length 18 ft (5.5 m); approx. diameter 7.42 mm |
| Other | Battery cable gauge | 3 | AWG | total cable length 14 ft (4.3 m); approx. diameter 6.61 mm |
| Other | Battery cable gauge | 4 | AWG | total cable length 10 ft (3 m); approx. diameter 5.88 mm |
| Other | Combustion Air | 18 CFM (30 M3/HR) | ||
| Other | Compression Ratio | 22.8:1 | ||
| Other | Compression Ratio | 23.5:1 | ||
| Other | Compression Ratio | 24.3:1 | ||
| Other | Compression Ratio | 24:1 | ||
| Other | Compression ratio | 22.5:1 | ||
| Other | Compression ratio | 22:1 | ||
| Other | Compression ratio | 23:1 | ||
| Other | Coolant Capacity | 2.2 quart (2.1 liter) | ||
| Other | Coolant Flow | 3.0 gpm (16 liter/min) | 50 Hz | |
| Other | Coolant Flow | 3.5 gpm (13 liter/min) | 60 Hz | |
| Other | Engine Oil Capacity | 2.2 quart (2.1 liter) | ||
| Other | Firing Order (Clockwise Rotation) | 1-2 | ||
| Other | Firing order (clockwise rotation) | 1-2-3 | ||
| Other | Firing order (clockwise rotation) | 1-2-4-3 | ||
| Other | Firing order (clockwise rotation) | 1-3-4-2 | ||
| Other | Firing order (clockwise rotation) | 1-3-5-4-2 | ||
| Other | Fuel Injection Order (Firing Order, clockwise rotation) | 1-2 | ||
| Other | Fuel pump delivery (test) | 2/3 | liter per minute | prime test, 1 liter container |
| Other | Fuel pump delivery rate | 2/3 liter per minute (1 liter in 1-1/2 minutes) | liter/min | prime mode |
| Other | Generator Cooling Air | 60-80 CFM (100-135 M3/HR) | ||
| Other | High AC Frequency shutdown (Code 14) | 70 Hz for 40 ms, or 2% over nominal for 6 seconds | after starter engaged | |
| Other | Low AC Frequency shutdown (Code 15) | 90 | % of nominal for more than 8 seconds | during normal operation |
| Other | Maximum Angularity | 10 deg Continuous, 22.5 deg Intermittent | deg | |
| Other | Maximum Fuel Pump Lift | 4 feet (1.2 m) with 3/8 inch ID fuel line | ||
| Other | Maximum Raw Water Pump Lift | 4 feet (1.2 m) with 5/8 inch ID hose |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | 50/50 water/ethylene glycol | 2.1 L | MDKBH; also stated as 2.2 Qt | ||
| Coolant | Fleetguard ES Compleat / EG Premix antifreeze (ethylene glycol based) | Purple coloured viscous liquid; boiling point 107 C, flash point 121 C. | |||
| Coolant | Fleetguard ES Compleat and EG Premix (ethylene glycol based) | ||||
| Coolant | 50/50 ethylene glycol/water | ASTM D5345 (prediluted) or ASTM D4985 (concentrated, 40-60% quality water) | above -37°C | Protects to -34°F (-37°C) | |
| Coolant | 50/50 ethylene glycol/water mixture | Fully formulated with rust inhibitors and coolant stabilizers | above -37°C | 5.0 liter | MDKAW, MDKAZ |
| Coolant | 50/50 mixture of water and ethylene glycol | above -37°C | 2.1 liter | Use best quality ethylene glycol antifreeze with rust inhibitors and coolant stabilizers; distilled water best. Protection down to -34°F (-37°C). | |
| Coolant | 50/50 mixture of water and ethylene glycol antifreeze | Fully formulated with rust inhibitors and coolant stabilizers; use low-mineral fresh water (distilled best) | above -37°C | 4.0 liter | MDKAV, MDKBG; mixture good for -34 F (-37 C) |
| Coolant | 50/50 mixture of water and ethylene glycol antifreeze, fully formulated with rust inhibitors and coolant stabilizers | ASTM D5345 for 50/50 prediluted coolant or ASTM D4985 for concentrated coolant with 40% to 60% quality water | above -37°C | 50/50 mixture gives protection from freezing down to -34 F (-37 C); use fresh water low in minerals and corrosive chemicals (distilled best) | |
| Coolant | Ethylene glycol antifreeze, 50/50 mixture of water and ethylene glycol | ASTM D5345 for 50/50 prediluted coolant or ASTM D4985 for concentrated coolant with 40% to 60% quality water | above -37°C | Provides protection from freezing down to -34 F (-37 C). Use fresh water low in minerals; distilled water is best. Fully formulated with rust inhibitors and coolant stabilizers. | |
| Coolant | Ethylene glycol antifreeze, fully formulated with rust inhibitors and coolant stabilizers; 50/50 mixture of water and ethylene glycol | above -37°C | 2.1 liter | Protection from freezing down to -34°F (-37°C); use fresh water low in minerals, distilled best | |
| Coolant | ethylene glycol antifreeze, 50/50 mixture with water | above -37°C | Good to -34F (-37C) | ||
| Coolant | ethylene glycol antifreeze, 50/50 mixture with water for freeze protection to -34°F (-37°C) | ASTM D5345 (50/50 prediluted) or ASTM D4985 (concentrated, 40-60% quality water) | above 37°C | distilled water best | |
| Engine oil | 15W40 | 2.1 L | MDKBH; also stated as 2.2 Qt. Shipped with 15W40 engine oil. | ||
| Engine oil | API CH-4 or better, SAE 15W-40 recommended year-round | API/SAE | Synthetic motor oil not recommended | ||
| Engine oil | API Service Category CI-4 or better; SAE 15W-40 recommended | API CI-4 | 2.1 liter | 2.2 quart (2.1 liter). Multigrade oils such as SAE 15W-40 are recommended for year-round use. | |
| Engine oil | API Service Category CI-4 or better; SAE 15W-40 recommended year-round | API | choose viscosity per Figure 3-1 ambient chart | ||
| Engine oil | Multigrade oils such as SAE 15W-40 recommended for year-round use; choose SAE viscosity grade per ambient temperature (Figure 3-1) | API Service Category CI-4 or better | 4.0 L for MDKBK/MDKBL; 4.3 L for MDKBM/MDKBN; 7.6 L for MDKBP/MDKBR; 12 L for MDKBS; 10.4 L for MDKBT/MDKBU | ||
| Engine oil | Premium Blue E 15W40 | 2.1 L (2.2 qt) | Lubricant oil - Premium Blue E 15W40 | ||
| Engine oil | SAE 10W-30 | RM92-8M0086220U6 / RM92-8M0086221U3 | |||
| Engine oil | SAE 15W-40 | API Class CH-4 or better | 4.3 liter | MDKAW, MDKAZ | |
| Engine oil | SAE 15W-40 (multi-grade recommended for year-round use) | API CF, CF-4, CG-4, CH-4 or CI-4 | Emissions-regulated areas: CF, CF-4, CG-4, CH-4 or CI-4 with low sulfur or ultra low sulfur fuel. Non-regulated areas with high sulfur fuel: CF class recommended; if CF-4/CG-4/CH-4/CI-4 used, change oil and oil filter twice as often. | ||
| Engine oil | SAE 15W-40 (multi-grade recommended for year-round use; choose viscosity grade per ambient temperature) | API Performance Class CH-4 or better | 4.0 liter | MDKAV, MDKBG; synthetic motor oil not recommended | |
| Engine oil | SAE 15W-40 (multigrade recommended for year-round use); choose viscosity grade for ambient temperature (Figure 3-1) | API Service Category CI-4 or better | |||
| Engine oil | SAE 15W-40 (multigrade) recommended for year-round use | API Service Category CI-4 or better | 2.1 liter | Choose viscosity grade appropriate for ambient temperatures expected until next scheduled oil change | |
| Engine oil | SAE 15W-40 multi-grade recommended for year-round use | API Service Category CI-4 or better | 2.1 liter | Choose viscosity grade appropriate for ambient temperatures expected until the next scheduled oil change (Figure 3-1) | |
| Engine oil | SAE 15W-40 multigrade recommended; choose viscosity grade per ambient temperature (Figure 3-1) | API Service Category CI-4 or better | Lube oil capacity: 4.2 quart (4.0 liter) MDKBK/MDKBL; 4.5 quart (4.3 liter) MDKBM/MDKBN; 8 quart (7.6 liter) MDKBP/MDKBR; 12.7 quart (12 liter) MDKBS; 11 quart (10.4 liter) MDKBT/MDKBU. Add 1 quart (0.9 liter) when level falls to ADD mark. | ||
| Engine oil | SAE 25W-40 | RM92-8M0086227U3 / RM92-8M0086224U3 | |||
| Engine oil | TC-W3 | TC-W3 | 2-cycle outboard oil; RM92-858026QB1U6 / RM92-858027QB1U3 / RM92-858037QB1U3 | ||
| Fuel | Gas Oil (red diesel, fuel oil, type A1 or A2) | USCG TYPE A1 or ISO 7840-A1 fuel hoses | |||
| Fuel | Grade 2-D diesel fuel | EN 590 or ASTM D975 | Use Grade 1-D diesel fuel if fuel tank is exposed to temperatures below 40 degrees F (5 degrees C); cetane number not less than 45; sulfur content not more than 0.5 percent by weight; lubricity min load level 3100 grams (ASTM D6078) or max scar diameter 0.45 mm (ASTM D6079 or ISO 12156-1) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 1 | High Engine Temperature | Engine coolant temperature exceeded design limit | Shutdown | Add coolant, repair leaks, replace thermostat, clean raw water tubes, flush coolant system |
| 2 | Low Oil Pressure | Low oil pressure | Shutdown | Add engine oil or drain excess oil |
| 3 | Service Check | Indicates presence of second-level shutdown | Shutdown | Check second-level shutdown code by pressing STOP once |
| 4 | Overcrank | Cranking exceeded 20 to 60 seconds without start | Shutdown | Check fuel tank, open valves, remove blockage, tighten fittings, replace fuel filter, prime |
| 5 | Warning - Shutdown due to Vessel CO | Dangerous levels of Carbon Monoxide in vessel | Shutdown | Get everyone out into fresh air immediately and seek medical attention |
| 7 | Loss of Raw Water Flow | Low raw water pressure in heat exchanger | Shutdown | Open sea cock, clean strainer, reconnect hoses, replace impeller |
| 12 | Overvoltage | Controller unable to maintain rated voltage | Shutdown | See an authorized Onan dealer |
| 13 | Undervoltage | Controller unable to maintain rated voltage | Shutdown | Reduce number of connected appliances |
| 14 | Overfrequency | Engine governor unable to maintain rated frequency | Shutdown | Reset breaker after starting, tighten fuel fittings, prime fuel system |
| 15 | Underfrequency | Engine governor unable to maintain rated frequency | Shutdown | Reduce appliances, check fuel, remove blockage, tighten fittings, prime |
| 17 | Over-Prime | Prime mode exceeded 5 minutes | Shutdown | Remove object holding control switch in prime position |
| 22 | Governor Overload | Maximum allowable time at full-duty cycle exceeded | Shutdown | Reduce appliances, check fuel, remove blockage, tighten fittings, prime |
| 23 | Faulty Oil Pressure Sender | Controller sensed grounded sender | Shutdown | See an authorized Onan dealer |
| 24 | Faulty Temperature Sender | Controller sensed open sender | Shutdown | See an authorized Onan dealer |
| 27 | Loss of Voltage Sense | Controller unable to sense output voltage | Shutdown | See an authorized Onan dealer |
| 29 | High Battery Voltage | Battery system at more than 19.2V (12VDC) or 38.4V (24V) | Shutdown | Check battery bank connections, select lower boost charge rate |
| 32 | STARTING FAULT | Controller could not detect cranking speed (quadrature zero crossings) for 3 seconds | Shutdown | De-energize PTO, run propulsion engines while starting, service battery connections, change oil viscosity, check starter relay K4, check wiring, service starter motor, service engine, replace controller |
| 35 | Control Card Failure | Microprocessor EEPROM error during self-test | Shutdown | See an authorized Onan dealer |
| 36 | Engine Stopped | Engine stopped without command by controller | Shutdown | Open fuel valves, check fuel tank, check mechanical damage, remove blockage, prime |
| 37 | Invalid Genset Configuration | Controller cannot determine genset operating parameters | Shutdown | See an authorized Onan dealer |
| 38 | Field Overload | High field voltage induced by high rotor temperature or low power factor loads | Shutdown | Remove blockages to generator airflow, reduce appliances |
| 41 | Grounded Rotor | F+ grounded | Shutdown | See an authorized Onan dealer |
| 42 | Processor Failure | Microprocessor ROM error during self-test | Shutdown | See an authorized Onan dealer |
| 43 | Processor Failure | Microprocessor RAM error during self-test | Shutdown | See an authorized Onan dealer |
| 45 | SPEED SENSE LOST | After start disconnect, controller lost speed sense (quadrature zero crossings) for 0.25 seconds | Shutdown | Check for open/shorted field (P3-7 to P3-8) and quadrature (P3-4 to P3-5) windings, service generator, replace controller |
| 46 | Genset Overload | The genset Controller shutdown the genset because engine load exceeded 135 percent of genset rating for 10 seconds | Shutdown | Reduce the number of loads on the genset. |
| 48 | Processor Failure | Controller unable to sense field voltage | Shutdown | See an authorized Onan dealer |
| 57 | OVERPRIME | A local or remote control switch was held in the Prime position for more than 5 minutes | Shutdown | Remove object holding switch in prime position, replace faulty control switch |
| 58 | High Exhaust Temperature | Exhaust temperature exceeded design limits | Shutdown | Reconnect/replace raw water hoses, replace impeller |
| 59 | Low Coolant Level | Coolant level low | Shutdown | Add coolant, repair leaks |
| 61 | Emergency Shutdown | Genset was shut down by fire suppression system or other external control | Shutdown | Make necessary repairs and reset external control |
| Code No. 5 | Warning - Shutdown due to Vessel CO | Shutdown occurring due to the vessel CO detector | Warning | All status indicator lights in the control circuit will also blink the fault code. See Troubleshooting Chapter of the Operator Manual. |
| Code No. 61 | Emergency Shutdown | Shutdown occurring due to external emergency shutdown device | Shutdown | All status indicator lights in the control circuit will also blink the fault code. See Troubleshooting Chapter of the Operator Manual. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Tools: Screwdriver
⚠ Keep your hands away from the engine belt and pulleys.
⚠ The actuator could overheat if the battery is left on more than 10 minutes.
⚠ Be prepared to clamp off supply and return fuel lines to stop the engine.
Tools: strobe or injector clamp-on tachometer, 12 volt battery, battery switch
⚠ Accidental or remote starting can cause severe personal injury; disconnect the negative battery cable.
⚠ Accidental or remote starting can cause severe personal injury or death.
⚠ Do not use the fuel injection timing marks when adjusting valve lash.
⚠ Hazardous voltage; touching live parts can cause severe personal injury or death
Tools: Accurate AC voltmeter and frequency meter
Tools: separate voltmeter
Tools: Separate voltmeter
⚠ When changing frequency, make sure the line circuit breakers are suitable for the new output.
⚠ In configuration mode the control will not start, prime or display faults.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 50 Hz: Disconnect J5 from P7 | J5, P6, P7 | Frequency selection jumper leads in the genset control box | ||
| 60 Hz: Connect J5 to P6 | J5, P6, P7 | Frequency selection jumper leads in the genset control box | ||
| HZ SEL / 60 HZ jumper leads in the control box | HZ SEL, 60 HZ | Connect for 60 Hz; disconnect for 50 Hz. Apply the appropriate reconfiguration label. Generator reconnection per schematic on Page A-2. | ||
| 220/208 | 3 | 12 Lead Reconnectable | Applies to MDKDP (60 Hz), MDKDR (60 Hz), MDKDS | |
| 220/380 | 3 | 12 Lead Reconnectable | Applies to MDKDP, MDKDR, MDKDT, MDKDU | |
| 3-phase | 3 | 12 Lead Reconnectable | Applies to MDDCW, MDDCU, MDDCY, MDDCS, MDDCT |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Part # | Description | Category |
|---|---|---|
| W1032216 | Secondary Element | Air filter |
| HCI634K | Alternator Model | Alternator |
| PI144D1 | Alternator Model | Alternator |
| UC224C | Alternator Model | Alternator |
| UC224E | Alternator Model | Alternator |
| UC274C | Alternator Model | Alternator |
| UC274F | Alternator Model | Alternator |
| UC274H | Alternator Model | Alternator |
| UC274K | Alternator Model | Alternator |
| W10118160 | Battery Handling | Battery |
| W10122110 | Connector Handling | Connector |
| W10111140 | Electrical Wiring Handling | Electrical |
| W10112160 | Securely Tighten Wiring Terminals | Electrical |
| W10113130 | Do Not Let Wiring Contact Dangerous Parts | Electrical |
| W10113880 | Securely Insert Grommet | Electrical |
| W10114580 | Securely Clamp Wiring | Electrical |
| W10115870 | Clamp Wiring Properly | Electrical |
| W10116700 | Do Not Get Wiring Caught by Parts During Installation | Electrical |
| W10117350 | Check Terminal Protection and Clamped Condition After Wiring Installation | Electrical |
| W10123460 | Repair Deformed Terminals, Remove Rust with Sandpaper | Electrical |
| W10124300 | Ensure Female Connectors Are Not Too Open | Electrical |
| W10125190 | Ensure Plastic Covers Are Large Enough to Cover Connectors | Electrical |
| W1017467 | Filter Element and Filter Bowl | Filter element and bowl |
| W10120920 | Fuse Handling | Fuse |
| 3A111-9554-1 | Safety Decal | Service part / kit |
| TA040-4965-2 | Safety Decal | Service part / kit |
| TA240-9848-1 | Safety Decal | Service part / kit |
| TAO40-4935-1 | Battery Safety Decal | Service part / kit |
| TAO40-4956-1 | Fuel Warning Decal | Service part / kit |
| TC030-3012-1 | Battery Safety Decal | Service part / kit |
| V2403-M-E3BG | Engine Model | Service part / kit |
| W10106000 | Tractor Serial Number, Engine Serial Number, Hour Meter | Service part / kit |
| W10109040 | Snap Rings, O-rings, Grease Application | Service part / kit |
| W1011077 | Cylinder Numbers | Service part / kit |
| W10126840 | Use Circuit Tester Correctly, Check Polarity and Range | Testers |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.
Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.
The Kubota V2403M engine has an oil capacity of 7.6 liters.
The Kubota V2403M has a displacement of 2.434 liters with 4 cylinders.
The Kubota V2403M powers 1 generator set(s), including Cummins/Onan MDKB.
A commonly reported issue on generators using the Kubota V2403M is: Starter engages-disengages (battery voltage dips below 6 volts while cranking—low battery charge, poor connections, long cables). Cause: Battery voltage dips below 6 volts while cranking—low battery charge, poor connections, long cables. Fix: Clean and tighten the positive (+) and negative (-) battery cable connections at the battery and genset (Page 3-6); Recharge or replace the battery. Refer to the battery manufacturer's recommendations; Increase battery cable size or run parallel cables.