Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Oil filter | Cartridge | — | |||
| Oil | 2.8 L | — | 100 hr |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
The Kohler CH980 4 Cycle is a 1 L engine rated at 3600 rpm. It powers generator sets from Kohler, including the 18RES. It holds 2.8 L (0.7 gal) of oil.
Also known as: Kohler CH980 4 Cycle
Part of the Kohler CH980 engine family — 3 variants share parts & fitment.
| Oil capacity | 2.8 L |
|---|---|
| Displacement | 0.999 L |
| Rated speed | 3600 rpm |
Compiled from service & troubleshooting documentation across every generator set that uses the Kohler CH980 4 Cycle.
| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Oil filter | Cartridge | — | |||
| Oil | 2.8 L | — | 100 hr |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Oil level | Check | 8 hr | 8 hours or before use; 8.5/12 kW models | |
| Air cleaner and precleaner (8.5/12RES) | Replace | 100 hr | 12 mo | Yearly or 100 hours; replace as necessary |
| Air cleaner and precleaner service | Clean | 100 hr | Yearly or 100 hours; 8.5/12 kW models; service more often in dusty/dirty conditions | |
| Air cleaner and precleaner service | Replace | 100 hr | 12 kW models; Yearly or 100 hours; replace as necessary | |
| Air cleaner and precleaner service (8.5/12 kW) | Replace | 100 hr | Yearly or 100 hours; service more frequently under dusty/dirty conditions | |
| Engine oil | Change | 150 hr | 12 mo | 8.5/12RES: yearly or 100 hours |
| Oil cooler | Clean | 100 hr | Yearly or 100 hours; 17/18 kW models | |
| Oil cooler | Inspect | 100 hr | Yearly or 100 hours (17/18 kW models) | |
| Oil cooler (17/18RES) | Clean | 100 hr | 12 mo | Yearly or 100 hours; inspect and clean |
| Air cleaner service | Clean | 150 hr | Yearly or hours shown; 17/18 kW models | |
| Air cleaner service (17/18 kW) | Replace | 150 hr | Yearly or 150/300 hours | |
| Change oil | Change | 150 hr | Yearly or 150 hours (17/18 kW models) | |
| Engine oil (17/18RES) | Change | 150 hr | 12 mo | Yearly or 150 hours |
| Oil | Change | 150 hr | Yearly or 150 hours; 17/18 kW models | |
| Oil filter (17/18RES) | Replace | 150 hr | 12 mo | Yearly or 150 hours |
| Spark plugs | Clean | 150 hr | Yearly or hours shown; 17/18 kW models | |
| Spark plugs (17/18 kW) | Replace | 150 hr | Yearly or 150/300 hours | |
| Oil filter | Replace | 200 hr | 12 mo | Yearly or 200 hours; 8.5/12 kW models |
| Replace filter (oil filter) | Replace | 200 hr | Yearly or 200 hours (8.5/12 kW models) | |
| Air cleaner service | Change | 300 hr | Yearly or hours shown; 17/18 kW models | |
| Air cleaner service | Replace | 300 hr | 18 kW models; 150/300 hours | |
| Spark plugs | Check | 300 hr | Yearly or 300 hours; 8.5/12 kW models | |
| Spark plugs | Replace | 300 hr | Yearly or hours shown; 17/18 kW models | |
| Spark plugs (8.5/12 kW) | Replace | 300 hr | Yearly or 300 hours | |
| Spark plugs (8.5/12RES) | Check | 300 hr | 12 mo | Yearly or 300 hours |
| Crankcase breather hose | Check | 500 hr | 12 mo | Yearly or 500 hours; 8.5/12 kW models |
| Replace stepper motor coupling and bushing | Replace | 500 hr | 500 hours; authorized distributor/dealer only | |
| Stepper motor coupling and bushing | Replace | 500 hr | Authorized distributor/dealer only; 8.5/12 kW models | |
| Wire-cable insulation condition | Inspect | 500 hr | 36 mo | 3 years or 500 hours |
| Wire-cable insulation condition | Test | 500 hr | 3 Years or 500 hours; 8.5/12 kW models | |
| Air ducts, louvers | Clean | 12 mo | Yearly | |
| Battery and rack | Clean | 12 mo | Yearly; remove corrosion, clean and dry | |
| Battery charger operation, charge rate | Check | 1 mo | Monthly | |
| Battery electrolyte level and specific gravity | Check | 12 mo | Yearly; not necessary for maintenance-free batteries | |
| Battery terminals | Clean | 12 mo | Yearly; clean and tighten | |
| Brushes and collector ring | Inspect | 12 mo | Yearly; authorized distributor/dealer only | |
| Control and power wiring connections | Other | 12 mo | Yearly; tighten | |
| Exhaust insulation, fire hazards | Inspect | 12 mo | Yearly | |
| Flexible fuel lines and connections | Inspect | 3 mo | Quarterly; replace as necessary | |
| Fuel piping | Inspect | 12 mo | Yearly |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Gap | Spark Plug Gap 12/17/18RES | 0.76 | mm (0.030 in.) | |
| Gap | Spark Plug Gap 8.5kW | 0.51 | mm (0.020 in.) | |
| Gap | Spark plug gap | 0.51 | mm | |
| Gap | Spark plug gap | 0.76 | mm (0.030 in.) | |
| Other | Battery minimum cold cranking amps | 525 | CCA | at 0F |
| Other | Combustion air requirement (60 Hz) | 1.1 (39.2) | m3/min. (cfm) | 60 Hz |
| Other | Combustion air requirement (60 Hz) | 1.62 (57.3) | m3/min. (cfm) | 60 Hz |
| Other | Cooling air requirement (60 Hz) | 26.9 (950) | m3/min. (cfm) | 60 Hz |
| Other | Cooling air requirement (60 Hz) | 28.0 (989) | m3/min. (cfm) | 60 Hz |
| Other | Engine oil capacity | 1.9 | L (2.0 qt.) | |
| Other | Engine oil capacity | 2.8 | L (3.0 qt.) approximately | |
| Other | Exhaust flow at rated kW | 3.8 (135) | m3/min (cfm) | at rated kW |
| Other | Exhaust flow at rated kW | 5.3 (187) | m3/min (cfm) | at rated kW |
| Other | Fuel flow rate, LP vapor | 203000 | Btu/hr. | |
| Other | Fuel flow rate, LP vapor | 280000 | Btu/hr. | |
| Other | Fuel flow rate, natural gas | 193000 | Btu/hr. | |
| Other | Fuel flow rate, natural gas | 242000 | Btu/hr. | |
| Other | Fuel system leak test pressure | 6-8 ounces per square inch (10-14 inches water column) | oz/in² | LPG vapor or natural gas system |
| Other | Nominal fuel rating, LP vapor | 2500 | Btu/ft3 | |
| Other | Nominal fuel rating, natural gas | 1000 | Btu/ft3 | |
| Other | Overfrequency shutdown threshold | 110 | % of system frequency setpoint | more than 5 seconds, active 10s after start |
| Other | Total inlet air requirement (60 Hz) | 28.0 (990) | m3/min. (cfm) | 60 Hz |
| Other | Total inlet air requirement (60 Hz) | 29.6 (1045) | m3/min. (cfm) | 60 Hz |
| Other | Underfrequency shutdown threshold | 54 | Hz | more than 5 seconds (or below 56.5 Hz for more than 60 seconds) |
| Pressure | Fuel supply pressure, LP vapor | 1.7--2.7 (7-11) | kPa (in. H2O) | |
| Pressure | Fuel supply pressure, natural gas | 1.3--2.7 (5-11) | kPa (in. H2O) | |
| Pressure | Fuel supply pressure, natural gas | 1.7--2.7 (7-11) | kPa (in. H2O) | |
| Pressure | Gas fuel system leak test pressure | 6--8 | ounces per square inch (10--14 inches water column) | fuel system test pressurized; use soap and water solution without ammonia or chlorine |
| Pressure | Gas fuel system leak test pressure | 6--8 (10--14) | ounces per square inch (inches water column) | fuel system test pressurized |
| Pressure | LP/natural gas fuel system leak test | 6--8 ounces per square inch (10--14 inches water column) | soap and water solution test pressure | |
| Pressure | Low oil pressure shutdown | 24.1 ±13.8 | kPa (3.5 psi ±1.5 psi) | |
| Speed | Crank cycle | 15 | seconds crank and 15 seconds off, 3 attempts | starting |
| Speed | Crank cycle | 15 seconds crank and 15 seconds off, 3 attempts | seconds | |
| Speed | Cut-in frequency | 47.5 | Hz | 50 Hz units |
| Speed | Cut-in frequency | 57.5 | Hz | 60 Hz units |
| Speed | Overfrequency shutdown threshold | 110% of system frequency setpoint for more than 5 seconds | % | active 10 seconds after engine start |
| Speed | Overspeed shutdown threshold | 110 | % of normal running speed | more than 0.3 seconds |
| Speed | Overspeed shutdown threshold | 110% of normal running speed for more than 0.3 seconds | % | |
| Speed | Rated engine speed | 3000 | rpm | 50 Hz operation |
| Speed | Rated engine speed | 3600 | rpm | 60 Hz operation |
| Speed | Underfrequency shutdown threshold | below 54 Hz for more than 5 seconds; below 56.5 Hz for more than 60 seconds | Hz | active 10 seconds after engine start |
| Temperature | Battery heater thermostat ON / OFF | 16-18 °C (60-65 °F) on; 27 °C (80 °F) off | °C | |
| Temperature | Carburetor heater thermostat OFF | 16 ± 3 | °C | 60 ± 5 °F |
| Temperature | Carburetor heater thermostat ON | 4 ± 3 | °C | 40 ± 5 °F |
| Temperature | Carburetor heater thermostat ON | 4 ± 4 | C (40 ± 7F) | |
| Temperature | Exhaust gas temperature exiting the enclosure at rated load | 216 (420) | C (F) | at rated kW |
| Temperature | Thermostat OFF | 16 ± 3 | °C | Thermostat OFF (60 ± 5°F) |
| Temperature | Thermostat ON | 4 ± 4 | °C | Thermostat ON (40 ± 7°F) |
| Torque | Spark Plug Torque | 24.4-29.8 | Nm (18-22 ft. lb.) | |
| Torque | Spark plug | 18-22 | ft. lb. | |
| Torque | Spark plug | 24.4--29.8 | Nm (18--22 ft. lb.) | |
| Torque | Spark plug | 24.4-29.8 | Nm | |
| Voltage | Battery charger charging voltages (red/green LED) | 11.8-14.0 V (bulk 6 A); 14.0-14.5 V (absorption 1.5-5 A); 13.0-13.6 V (float 0.1-1.5 A) | VDC | 6-amp RES charger |
| Voltage | Battery charger output | 6 | amps | |
| Voltage | Battery charger output (RES, 6 Amp) | 12 | VDC @ 6 Amps | INPUT 115 VAC 50/60Hz @ 1.6A |
| Voltage | Battery charger output (TRES, 2.5 Amp) | 13.2 | VDC | verify with battery disconnected |
| Voltage | Battery charger output (green LED on, FLOAT/MAINTENANCE stage) | 13.0--13.6 | V | 0.1--1.5 amps |
| Voltage | Battery charger output (red LED on, BULK stage) | 11.8--14.0 | V | 6 amps; battery charger on |
| Voltage | Battery charger output (red and green LEDs on, ABSORPTION stage) | 14.0--14.5 | V | 1.5--5.0 amps |
| Voltage | Battery charger output, 6-amp RES | 12 | VDC | @ 6 Amps; input 115 VAC 50/60Hz @ 1.6A; max battery 180 Amp Hr. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | 5W-30 | API Service Class SG, SH, or SJ synthetic | 2.8 L | 18 kW models; approximately 2.8 L (3.0 qt.) | |
| Engine oil | Synthetic | API Service Class SG or higher | Use synthetic oil, API Service Class SG or higher | ||
| Engine oil | Synthetic oil | API Service Class SG or higher | Maintain oil level at or near, not over, the full mark on the dipstick. See TP-6517 Operation Manual for additional information. | ||
| Engine oil | 10W-30; 5W-20, 5W-30 | API Service Class SG, SH, or SJ synthetic | -30°C to 40°C | 1.9 L | 12 kW models; select viscosity based on air temperature expected before next oil change |
| Fuel | LP vapor | Nominal fuel rating 93 MJ/m3 (2500 Btu/ft.3). Fuel supply inlet 1/2 NPT. | |||
| Fuel | LP vapor, 93 MJ/m3 (2500 Btu/ft3) | Nominal fuel rating | |||
| Fuel | LPG | Fuel supply pressure 1.7-2.7 kPa (7-11 in H2O); nominal fuel rating 2500 Btu/ft3 (93 MJ/m3); supply inlet 1/2 NPT | |||
| Fuel | Natural Gas | Fuel supply pressure 1.3-2.7 kPa (5-11 in H2O) for 8.5/12RES, 1.7-2.7 kPa (7-11 in H2O) for 18RES; nominal fuel rating 1000 Btu/ft3 (37 MJ/m3); supply inlet 1/2 NPT | |||
| Fuel | Natural gas | Nominal fuel rating 37 MJ/m3 (1000 Btu/ft.3). Fuel supply inlet 1/2 NPT. | |||
| Fuel | Natural gas or propane (LP) vapor | Field-convertible multi-fuel; CARB emission certified | Clean-burning natural gas or propane (LP) vapor; air-cooled engine, no liquid coolant | ||
| Fuel | Natural gas, 37 MJ/m3 (1000 Btu/ft3) | Nominal fuel rating | |||
| Other | Bicarbonate of soda (baking soda) and water solution | Battery acid cleanup: 500 g (1 lb.) bicarbonate of soda to 4 L (1 gal.) water; also used to clean battery and cables | |||
| Other | Petroleum jelly, silicone grease, or other nonconductive grease | Coat battery terminals after reconnecting cables |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| AF | Auxiliary fault input shutdown | Shutdown initiated by pushing the emergency stop switch (TRES models only). Not used on RES models. | Shutdown | Check the position of the emergency stop button (TRES models only). |
| CC | Crank cycle | |||
| HB | High battery voltage warning | Displayed if engine starting battery voltage rises above 16 VDC for more than 30 seconds when engine is running. | Warning | Check the battery rating and condition; check battery charger operation. |
| HE | High engine temperature shutdown | Shutdown occurs if the engine coolant temperature exceeds the maximum for more than 5 seconds. Active after engine reaches crank disconnect speed. | Shutdown | Check for blocked air inlets and exhaust outlets. |
| LB | Low battery voltage warning | Displayed if engine starting battery voltage falls below 11 VDC for more than 30 seconds when engine is not running. | Warning | Check the battery rating and condition; check battery charger operation; charge or replace battery. |
| LCL | Low coolant level | FMI 1, SPN 0x006F | ||
| LO P | Low oil pressure shutdown | Shutdown occurs if a low oil pressure condition exists for more than 5 seconds. Active 30 seconds after crank disconnect speed. Does not protect against low oil level. | Shutdown | Check for leaks in the lubrication system. Check the oil level and add oil if the level is low. |
| LOC | Loss of coolant | FMI 1, SPN 0x006F | ||
| LOP | Low oil pressure shutdown | Shutdown occurs if a low oil pressure condition exists for more than 5 seconds. Active 30 seconds after crank disconnect speed. | Shutdown | Check for leaks in lubrication system; check oil level and add oil if low. |
| OC | Overcrank shutdown | Shutdown after 3 unsuccessful starting attempts (15s crank, 15s rest each). Also on locked rotor if no engine rotation sensed during cranking. | Shutdown | Check fuel supply, spark plug, battery, loose connections. Contact dealer if problem continues. |
| OF | Overfrequency shutdown | Shutdown occurs when governed frequency exceeds 110% of system frequency setpoint for more than 5 seconds. Active 10 seconds after engine start. | Shutdown | Contact an authorized distributor/dealer for service if problem continues. |
| OS | Overspeed shutdown | Shutdown occurs if engine speed exceeds 110% of normal running speed for more than 0.3 seconds. | Shutdown | Contact an authorized distributor/dealer for service if problem continues. |
| OU | Overvoltage shutdown | Shutdown occurs if voltage exceeds 120% of system nominal voltage for more than 2 seconds. | Shutdown | Contact an authorized distributor/dealer for service if problem continues. |
| UF | Underfrequency shutdown | Shutdown occurs if governed frequency falls below 54 Hz for more than 5 seconds, or below 56.5 Hz for more than 60 seconds. Active 10 seconds after engine start. | Shutdown | Reduce load and restart; contact dealer if problem continues. |
| UU | Undervoltage shutdown | Shutdown occurs if voltage falls below 80% of nominal system voltage for more than 10 seconds. | Shutdown | Reduce load and restart; contact dealer if problem continues. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
⚠ The controller automatically exits configuration mode without saving changes after about 1 minute if no buttons are pressed.
Tools: frequency meter
⚠ Explosive fuel vapors. Can cause severe injury or death. Use extreme care when handling, storing, and using fuels.
⚠ Accidental starting. Disconnect the battery cables before working on the generator set; remove the negative (--) lead first.
Tools: Gas leak detector, Wrench (to hold fuel solenoid valve)
Tools: digital multimeter
⚠ Always identify and correct the cause of a fault shutdown before resetting the controller.
Tools: DeviceInstaller software
⚠ Sulfuric acid in batteries. Can cause severe injury or death. Wear protective goggles and clothing.
⚠ Explosion. Relays in the battery charger cause arcs or sparks. Locate the battery in a well-ventilated area.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| DSAI (Digital Spark Advance) leads | 65 and N5 | Connect for natural gas; disconnect for LP | ||
| Field-connection terminal block — L1 and L2 | Leads from transfer switch emergency source lugs to L1 and L2 | See decal near the terminal block for connections | ||
| Remote start | Engine start leads from terminals 3 and 4 | Route engine start leads through separate conduit from AC power and load leads | ||
| single phase | Field-connection terminal block | L1, L2 (load), L0 (neutral), GRD (ground), terminals 3 and 4 (engine start) | Connect transfer switch emergency source leads to L1 and L2; neutral L0 and ground GRD from ATS and main panel; engine start leads to terminals 3 and 4. Generator sets shipped with neutral bonded to ground in junction box; neutral may be grounded or lifted/is isolated if installation requires ungrounded neutral. See Section 2 wiring diagrams: 12RESL/12RESM1 schematic ADV-7325, point-to-point GM51414; 18RESL schematic ADV-7353, point-to-point GM52541. | |
| 120 VAC | Utility Power terminals on field-connection terminal block | Utility power circuit must be backed up by the generator set |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Part # | Description | Category |
|---|---|---|
| 62 083 01-S | Element, air filter | Air filter |
| RSP-FT-03-US-01 | Pack first: complete service kit comprising air filter, air pre filter, spark plugs and oil filter. | Air filter |
| RSP-FT-05-US-01 | Pack first: complete service kit comprising air filter, air pre filter, spark plugs and oil filter. | Air filter |
| 25 158 08-S | Bushing, linkage retaining | Bushing |
| 358358 | Coupling, stepper motor | Coupling |
| 25 435 06-S | Kit, starter solenoid | Kit |
| 52 050 02-S | Filter, oil | Oil filter |
| 223316 | Fuse, 10 A, 250 V | Service part / kit |
| 292937 | Fuse, 20 A, 250 V | Service part / kit |
| AGS-10 | AGS 10 inline fuse, battery charger (located in the battery lead) | Service part / kit |
| GM58703 | Assy, J1939/ModBus/Ethernet Converter (network bridge) | Service part / kit |
| GM62347 | Kit, Resi Maint (17RES) (4/cs) | Service part / kit |
| X-634-28 | Bushing | Service part / kit |
| 52 099 08-S | Switch, oil pressure | Sensor |
| GM28823 | Sensor, oil temperature | Sensor |
| 62 132 04-S | Spark plug | Spark plug |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
The Kohler CH980 4 Cycle engine has an oil capacity of 2.8 liters.
The Kohler CH980 4 Cycle has a displacement of 0.999 liters.
The Kohler CH980 4 Cycle powers 1 generator set(s), including Kohler 18RES.
The Kohler CH980 4 Cycle oil change interval is every 100 hours.
A commonly reported issue on generators using the Kohler CH980 4 Cycle is: Generator set stops suddenly.. Cause: Low oil pressure shutdown. Fix: Check the oil level..