The Kohler CH740 or CH1000 is a 2-cylinder air-cooled engine. It powers generator sets from Kohler, including the RDC2 or DC2 and TP-6804.
Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|
| Air filter | KOHLER OE | | — | 1200 hr | |
| Fuel filter | KOHLER OE | | — | 1200 hr | |
| Oil filter | KOHLER OE | | — | 1200 hr | |
| Battery | Battery gases. Explosion can cause severe injury or death. | | — | 1800 hr | |
| Belt | Inspect belts for wear and replace as necessary. | | — | 2400 hr | |
| Coolant | DOT5.1 | 10.0 L | — | 3600 hr | |
| Oil | 5W-40 | 4.5 L | — | 1200 hr | |
| Spark plug | | | — | 1000 hr | |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Procedures
12Étalonnage du contrôleur RDC/DC adjustment
⚠ Observer les précautions de sécurité indiquées dans le manuel d'installation de groupe électrogène.
Tools: Voltmètre numérique
- Mesurer la tension réelle du secteur au niveau de L1 et L2 avec un voltmètre numérique.
- Cliquer sur Calibrate (Étalonner) dans le ruban en haut de l'écran SiteTech.
- Tapez la tension mesurée dans la fenêtre d'étalonnage d'appareil.
- Cliquer sur le bouton Calibrate (Étalonner) dans la fenêtre d'étalonnage.
Obtain DC2 Controller Password and Serial Number diagnostic
- Press OFF and verify that the generator set is not running.
- Press and hold the Exercise button until Press Again to Reset OnCue Plus PW is displayed.
- Release the Exercise button and press it again within 5 seconds.
- Write down the serial number (S/N) and password.
Obtain RDC/DC Controller Password diagnostic
- Press OFF to place the controller into OFF mode.
- Press the down arrow button (RDC) or exercise button (DC) 5 times.
- Note the four-digit code displayed on the controller; this is the controller password.
- Write down the password and press OFF to clear the display.
Obtain RDC2 or VSC Controller Password and Serial Number diagnostic
- Press the controller down arrow button to navigate to the Networking Information menu.
- Follow the reset password procedure shown in Figure 1-3.
- Write down the serial number (S/N) and password displayed for 10 seconds.
Power Cycle the Controller diagnostic
- Disconnect all input power for two minutes to allow capacitors to discharge.
- Remove the battery negative cable or disconnect P1 from the back of the controller.
- Disconnect the battery charger 120 VAC input power supply or disconnect P5 from the back of the controller.
- Unplug the USB mini-B connector from the front of the controller if plugged in.
- Wait two minutes, then reconnect power, hooking up battery power (P1) first.
Use Telnet to Check Server Connection diagnostic
Tools: Command prompt, Telnet Client
- Activate Telnet Client on the computer if necessary.
- Open a command prompt window.
- Enter telnet devices.kohler.com 5253.
- Successful connection displays the symbols shown in Figure 3-8.
Connect OnCue Plus for RDC/DC installation
- Install the Ethernet option board on the generator set controller. See TT-1566.
- Connect a network cable from the Ethernet board to your router or modem.
Connect OnCue Plus for RDC2/DC2/VSC installation
- Set the controller password before connecting the generator set Ethernet cable to the router.
- Connect the RJ45 inline connector included in the OnCue Plus kit to the Ethernet cable inside the generator enclosure.
- Connect one end of the customer-provided network cable to the RJ45 connector.
- Connect the other end of the network cable to the customer router or modem.
Connexion USB d'un appareil installation
⚠ Ne pas utiliser de connecteur micro-B.
Tools: Câble USB (type-B ou mini-B)
- Connecter un câble USB doté du connecteur approprié (type-B standard pour ADC IId, mini-B pour les autres appareils).
- Sélectionner No, not at this time (Non pas pour le moment) et cliquer sur Next (Suivante).
- Sélectionner Install the software automatically (Installer le logiciel automatiquement) et cliquer sur Next.
- Cliquer sur Finish (Terminer).
Install OnCue Plus Wireless for RDC2/DC2 installation
- Set the controller password.
- Follow instructions in TT-1618 to install, connect, and set up the wireless access point.
- The customer must have a wireless router for Internet access.
Installer SiteTech installation
- Lire l'écran de contrat de licence et cocher la case indiquant l'acceptation des termes.
- Cliquer sur Install (Installer) et patienter pendant l'installation.
- Cliquer sur Finish (Terminer).
Mise à jour du progiciel maintenance
⚠ Pour le RSA II uniquement : ne pas tenter de mettre à jour le progiciel sur les tableaux d'alarme RSA II à l'aide de la version 1.0 du progiciel.
⚠ Les contrôleurs Decision-Maker 550 et 6000 exigent un logiciel chargeur de programme pour la mise à jour du progiciel.
Tools: Câble USB
- Télécharger le nouveau fichier de progiciel (.bin) depuis TechTools ou le portail des revendeurs Kohler.
- Connecter l'appareil à un port USB du PC.
- Démarrer SiteTech (Start>Programs>Kohler SiteTech) et laisser reconnaître l'appareil.
- Cliquer sur Update Firmware (Mettre à jour progiciel).
- Cliquer sur Browse (Naviguer), sélectionner le fichier .bin et cliquer sur Open (Ouvrir).
- Vérifier la version courante et la nouvelle version, puis cliquer sur Update Firmware.
- Cliquer sur Close (Fermer) quand Firmware Updated Successfully s'affiche.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
Which generators use the Kohler CH740 or CH1000 engine?
The Kohler CH740 or CH1000 powers 2 generator set(s), including Kohler RDC2 or DC2, Kohler TP-6804.
How often should you change the oil in the Kohler CH740 or CH1000?
The Kohler CH740 or CH1000 oil change interval is every 1200 hours.
What is a common problem with the Kohler CH740 or CH1000 engine?
A commonly reported issue on generators using the Kohler CH740 or CH1000 is: Generator set stops suddenly. Cause: Low oil pressure shutdown. Fix: Check for oil leaks. Check the oil level and add oil if necessary.