Home›Engines›John Deere 4045HF285K

John Deere 4045HF285K Engine

The John Deere 4045HF285K is a 4.5 L 4-cylinder turbocharged, charge air-cooled engine rated at 1800 rpm, producing up to 147 kW. It powers generator sets from Kohler, including the 125REOZJG. It holds 13.9 L (3.7 gal) of oil and 19.2 L (5.1 gal) of coolant.

Also known as: John Deere 4045HF285K

Part of the John Deere 4045 engine family — 118 variants share parts & fitment.

4.5 L
Displacement
4
Cylinders
1800 rpm
Rated speed
147 kW
Gross power

Service parts for the 4045HF285K

The cheapest captured merchant offer per filter — see the full cross-reference below for every OEM/aftermarket option.

Air intake

1 required
AL204809Air filterfind

Fuel system

1 required
GM50006Fuel filter (primary)$26.99eBay

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Verify against your serial number before ordering.

Engine specifications

Oil capacity13.9 L
Coolant capacity19.2 L
Displacement4.5 L
Cylinders4
AspirationTurbocharged, Charge Air-Cooled
Rated speed1800 rpm
Gross power147 kW

Common problems

6
  • Emergency Stop 32A
    Fix: Reset the emergency stop switch.
  • Pre Low Oil Pressure 41
    Fix: Check and adjust oil level or replace oil pump.
  • Pre High Coolant Temp. 40
  • Low Fuel 63
    Fix: Refuel the generator set.
  • Low Battery Volts 62
  • High Coolant Temperature 32

Compiled from service & troubleshooting documentation across every generator set that uses the John Deere 4045HF285K.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterDry—
Fuel filterSecondaryGM50006 Amazon eBay $26.99 NAPA $44.17
Oil filterCartridgeGM32809 Amazon Amazon Amazon Amazon eBay $26.25 NAPA $28.76

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service specifications

50
TypeItemValueUnitCondition
GapSpeed sensor air gap0.36- 0.71mm
Other10 in. weld flange bolt circle diameter B361.95mm (14.25 in.)
Other10 in. weld flange outside diameter C406.4mm (16.0 in.)
Other10 in. weld flange quantity of bolts / bolt hole diameter D12, 25.40mm (1.00 in.)
Other12 in. weld flange bolt circle diameter B431.80mm (17.00 in.)
Other12 in. weld flange outside diameter C482.6mm (19.0 in.)
Other12 in. weld flange quantity of bolts / bolt hole diameter D12, 25.40mm (1.00 in.)
Other14 in. weld flange bolt circle diameter B476.25mm (18.75 in.)
Other14 in. weld flange outside diameter C533.4mm (21.0 in.)
Other14 in. weld flange quantity of bolts / bolt hole diameter D12, 28.58mm (1.13 in.)
Other16 in. weld flange bolt circle diameter B539.75mm (21.25 in.)
Other16 in. weld flange outside diameter C596.9mm (23.5 in.)
Other16 in. weld flange quantity of bolts / bolt hole diameter D16, 28.58mm (1.13 in.)
Other18 in. weld flange bolt circle diameter B577.85mm (22.75 in.)
Other18 in. weld flange outside diameter C635.0mm (25.0 in.)
Other18 in. weld flange quantity of bolts / bolt hole diameter D16, 31.75mm (1.25 in.)
Other20 in. weld flange bolt circle diameter B635.00mm (25.00 in.)
Other20 in. weld flange outside diameter C698.5mm (27.5 in.)
Other20 in. weld flange quantity of bolts / bolt hole diameter D20, 31.75mm (1.25 in.)
Other5 in. weld flange bolt circle diameter B215.90mm (8.50 in.)
Other5 in. weld flange outside diameter C241.30mm (9.50 in.)
Other5 in. weld flange quantity of bolts / bolt hole diameter D8, 22.23mm (0.88 in.)
Other6 in. weld flange bolt circle diameter B254.0mm (10.0 in.)
Other6 in. weld flange outside diameter C279.4mm (11.0 in.)
Other6 in. weld flange quantity of bolts / bolt hole diameter D8, 22.23mm (0.88 in.)
Other8 in. weld flange bolt circle diameter B298.45mm (11.75 in.)
Other8 in. weld flange outside diameter C342.9mm (13.5 in.)
Other8 in. weld flange quantity of bolts / bolt hole diameter D8, 22.23mm (0.88 in.)
OtherWeld flange angle A (10, 12, 14 in. nominal pipe size)30deg.
OtherWeld flange angle A (16, 18, 20 in. nominal pipe size)22.5deg.
OtherWeld flange angle A (5, 6, 8 in. nominal pipe size)45deg.
PressureBattery equalizer input voltage (24 volts nominal)20- 35volts
PressureBattery equalizer output voltage(input voltage/2) ±2%volts
PressurePressure switch 364345483 ±14kPa
ResistancePressure sender 264390 value A240 +17/- 15ohms at 0 psi
ResistancePressure sender 264390 value B153 +12/- 15ohms at 25 psi
ResistancePressure sender 264390 value C33.5ohms at 100 psi
ResistancePressure sender 365624 value A241 ±16ohms at 0 psi
ResistancePressure sender 365624 value B152 ±13ohms at 50 psi
ResistancePressure sender 365624 value C33.5ohms at 200 psi
ResistanceTemperature sender 226717 value A123.8 +7.2/- 7.8ohms at 90.6 C (195 F)
ResistanceTemperature sender 226717 value B35.6 +3.4/- 3.6ohms at 137.8 C (280 F)
ResistanceTemperature sender 226919 value A942 ±22ohms at 37.7 C (100 F)
ResistanceTemperature sender 226919 value B35ohms at 115.6 C (240 F)
SpeedOverspeed shutdown70Hz60 Hz models
TemperatureBattery equalizer operating temperature- 40 to 71C (- 40 F to 160 F)
TemperatureTemperature switch 241308107 ±4C (225 F ±7 F)normally open to close on temp. rise
TemperatureTemperature switch 290090/GM5170516 ±3C (60 F ±5 F)normally open to close on temp. fall
VoltageSpeed sensor voltage, wire 2 (black) & 16 (white)3- 6volts DC
VoltageSpeed sensor voltage, wire 2 (black) & 24 (red)8- 10volts DC

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Overfrequency Adjustment (Over/Underfrequency Relay, Decision-Maker 3+) adjustment
  1. Turn the overfrequency adjustment potentiometer fully clockwise (CW).
  2. Place master switch in RUN to start the generator set.
  3. Adjust governor per engine operation manual, engine service manual, or governor section of this manual.
  4. Slowly turn overfrequency potentiometer counterclockwise (CCW) until the LED starts flashing; after about 10 seconds the set shuts down on auxiliary fault.
  5. Place master switch to OFF/RESET to reset the controller.
  6. Place master switch to RUN to start the generator set.
  7. Readjust the governor to the desired frequency as required.
  8. Place master switch to OFF/RESET to stop the generator set.
Overvoltage Feature Testing and Adjustment (Decision-Maker 3+) adjustment

⚠ Hazardous voltage. Moving parts. Will cause severe injury or death. Operate the generator set only when all guards and electrical enclosures are in place.

⚠ Disconnecting the electrical load. Hazardous voltage will cause severe injury or death.

  1. Disconnect generator set from load by opening line circuit breaker or disconnecting and taping output leads.
  2. Determine overvoltage shutdown value based on user requirement; factory setting is 15% above nominal line-to-neutral voltage.
  3. Remove the controller cover.
  4. Place master switch in RUN to start the generator set.
  5. Observe AC voltmeter; turn voltage adjustment potentiometer CW until generator set shuts down.
  6. If the shutdown point is correct, go to step 12; otherwise continue.
  7. Turn controller circuit board R42 adjustment potentiometer fully CW.
  8. Place master switch to OFF/RESET to reset; then to RUN to start.
  9. Observe AC voltmeter while turning voltage adjustment potentiometer to desired overvoltage shutdown point.
  10. Turn R42 adjustment potentiometer slowly CCW until the generator set shuts down.
  11. Turn controller voltage adjustment potentiometer slightly CCW.
  12. Place master switch OFF/RESET then RUN to start; adjust for correct voltage and phase.
  13. Place master switch OFF/RESET to stop.
  14. Disconnect battery negative lead first; reconnect generator set to load; reconnect battery negative lead last.
Reactive Droop Compensator Adjustment Procedure adjustment

Tools: Voltmeter, Wattmeter

  1. Remove any load; start each generator set with master switch in RUN.
  2. Set reactive droop compensator rheostat on generator set no. 1 to minimum CCW; record rpm/frequency and voltage at 1/4 load steps to full load.
  3. Repeat for generator set no. 2.
  4. Compare readings; adjust voltage within 1 volt and speed within 3 rpm (or 0.1 Hz) at each load step.
  5. Check droop compensation on each unit with an inductive load 1/2 to full load.
  6. Adjust rheostat to approximately 4% below rated voltage at full load.
  7. Repeat for unit no. 2.
Reactive Droop Compensator Alternate Adjustment Procedure adjustment

Tools: Voltmeter

  1. Turn reactive droop compensator rheostat on generator set no. 1 to minimum setting.
  2. Remove controller cover; move voltage sensing lead from V7 to V9 at the AC fuse terminal block.
  3. Remove any load connected to the generator set.
  4. Start the generator set with master switch in RUN.
  5. Use controller or remote voltage adjusting potentiometer to fine adjust voltage.
  6. Apply resistive load (1.0 power factor) until reaching rated current.
  7. Adjust reactive droop compensator rheostat to achieve a 4% droop in voltage.
  8. Remove the resistive load and stop the generator set.
  9. Return voltage sensing lead from V9 to V7 at the AC fuse terminal block.
  10. Replace the controller cover and repeat for generator set no. 2.
Underfrequency Adjustment (Over/Underfrequency Relay, Decision-Maker 3+) adjustment
  1. Turn underfrequency adjustment potentiometer fully clockwise (CW).
  2. Place master switch in RUN to start the generator set.
  3. Adjust governor per engine operation manual, engine service manual, or governor section of this manual.
  4. Slowly turn underfrequency potentiometer counterclockwise (CCW) until LED starts flashing; after about 10 seconds the set shuts down on auxiliary fault.
  5. Place master switch to OFF/RESET to reset the controller.
  6. Place master switch to RUN to start the generator set.
  7. Readjust the governor to the desired frequency as required.
  8. Place master switch to OFF/RESET to stop the generator set.
2-Wire Low Water Level Sender Test diagnostic

⚠ Hot engine and exhaust system can cause severe injury or death. Do not work on the generator set until it cools.

⚠ Hazardous voltage. Moving parts. Will cause severe injury or death. Operate the generator set only when all guards and electrical enclosures are in place.

Tools: DC voltmeter

  1. Measure DC voltage between lead 31A (+) and ground (- ) with sender submerged in coolant; voltmeter indicates approximately 12.5 VDC.
  2. Measure DC voltage between lead 31A (+) and ground (- ) with sender removed from coolant for at least 5-15 seconds; voltmeter indicates a drop to approximately 7 VDC.
3-Wire Low Water Level Sender Test diagnostic

⚠ Hot engine and exhaust system can cause severe injury or death. Do not work on the generator set until it cools.

⚠ Hazardous voltage. Moving parts. Will cause severe injury or death.

Tools: Ohmmeter

  1. Measure resistance between lead 31 and ground with sender submerged in coolant; ohmmeter indicates a high resistance reading.
  2. Measure resistance between lead 31 and ground with sender removed from coolant for at least 5-15 seconds; ohmmeter indicates a low resistance reading.
Battery Equalizer Troubleshooting diagnostic

⚠ To prevent reverse polarity damage to the battery equalizer, remove the ground (GND) connection first and attach the ground connection last when disconnecting the battery equalizer.

Tools: 12-volt test light with alligator clips, Voltmeter with 0.01 volt resolution, Battery load tester

  1. Remove the ground (GND) connections from the battery equalizer; do not allow contact with other connections.
  2. Verify a differential of 12 volts between the +12 volt and +24 volt terminals using a 12-volt test light; the light will illuminate on a functional unit. Remove the test light.
  3. Connect the test light between the +12 volt and GND terminals; the light will illuminate on a functional unit.
  4. With the test light connected, measure and record the voltage between the +12 volt and +24 volt terminals.
  5. With the test light connected, measure and record the voltage between the +12 volt and GND terminals.
  6. Remove the test light.
  7. Compare the values from steps 4 and 5; the difference should be - 0.5 and +0.13 volts on a functional unit.
Oil Pressure Sender Testing diagnostic

Tools: Ohmmeter, Mechanical oil pressure gauge

  1. Disconnect the oil pressure sender lead 7C.
  2. Check the sender resistance with an ohmmeter.
  3. Compare resistance values when the generator set is shut down and when running at operating temperature to Section 1, Specifications.
  4. Use a mechanical oil pressure gauge to further verify correct readings.
Overcrank Test (Typical) diagnostic
  1. On gas-fueled sets, disconnect the coil wire at the distributor cap and ground it or disconnect the ignition system.
  2. On diesel-fueled sets, unplug the fuel injector harness from ECM or disconnect wire no. 70 from the injector pump solenoid.
  3. Place unit in RUN mode; observe 15-second on-off cranking cycles and maximum 75-second elapsed time to overcrank shutdown.
  4. Observe controller fault lamp and display for an overcrank shutdown.
  5. Place unit in OFF/RESET mode.
  6. Reconnect the ignition coil wire/ignition system, or reconnect the fuel injector harness/wire no. 70.
Speed Sensor Test with Generator Set Running diagnostic

⚠ Keep leads connected to the speed sensor terminals during the test; do not disconnect the leads.

Tools: DC voltmeter

  1. Connect a DC voltmeter between positive (+) lead (wire 24) at the speed sensor and ground (wire 2) with master switch OFF/RESET; read approximately 8- 12 volts DC.
  2. Place master switch in RUN to start the generator set.
  3. Connect DC voltmeter negative probe to 0 terminal (wire 16 white) and positive probe to positive (+) terminal (wire 24 red); read approximately 7- 12 volts DC.
  4. Place master switch in OFF/RESET to stop the generator set.
  5. If sensor emits a signal, check continuity of speed sensor leads (wires 2, 16, 24) between controller P1 connector and sensor terminals.
Speed Sensor Test with Separate 12 VDC Source diagnostic

Tools: DC voltmeter, 12-volt battery or DC power supply, Flat piece of iron or steel

  1. Place master switch in OFF/RESET position.
  2. Disconnect the speed sensor leads.
  3. Connect speed sensor, DC voltmeter, and DC voltage source as shown.
  4. Touch sensing surface with a flat piece of iron or steel at least 4.1 cm (1/4 cu. in.) in size.
  5. DC voltmeter reading should equal the source voltage, approximately 12 VDC.
  6. Remove the iron or steel piece and observe a voltmeter reading of 0 VDC.
  7. If the sensor passes, it is functional; replace if it fails.
  8. Connect the speed sensor leads and adjust the air gap.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
12-lead optional voltage connections12Alternator optional feature
4-lead dedicated voltages4Alternator standard feature
110/127/139/240/254/277single-phaseswitchableTowable generator model specifications; some models n/a
208/220/240/415/440/4803-phasereconnectableTowable generator model specifications
208/220/240/415/440/4803-phaseswitchableTowable generator model specifications

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the John Deere 4045 family

300
Part #DescriptionCategory
10-20-08Net engine power is with standard equipment including air cleaner, exhaust system, alternator, and cooling fan at test conditions specified per ISO9249 No derating is required up to 5,000-ft. (1500 m) altitude.Air filter
100-001Air FilterAir filter
100-025Air FilterAir filter
24-20001Air FilterAir filter
24-20018Crankcase Breather Filter, Right handAir filter
24-21000Air FilterAir filter
24-21003Air FilterAir filter
24-21406Air FilterAir filter
25-1476Air Filter MindersAir filter
25-1483Primary Air CleanersAir filter
253108Element, air cleanerAir filter
29765Filter, airAir filter
301315Air Filter Element for CompressorAir filter
30561Element, air filterAir filter
30562Element, air filter safetyAir filter
35393651Air Cleaner Element (Compressor) secondary - optionalAir filter
35393685Air Cleaner Element (Compressor) primaryAir filter
AR79679Air FilterAir filter
AR79680Filter ElementAir filter
AT203469Outer ElementAir filter
AT203470Inner ElementAir filter
AT203471Air Filter Assembly (Includes Keys #1-7)Air filter
DZi05100CRANKCASE VENT SYSTEM OCV FILTERAir filter
F1000000001Air FilterAir filter
G030070Air Cleaner Element (Engine) PrimaryAir filter
G030071Air Cleaner Element (Engine) SecondaryAir filter
G030073Air Cleaner Element (Engine) PrimaryAir filter
G030074Air Cleaner Element (Engine) SecondaryAir filter
G030077Air Cleaner Element (Engine) PrimaryAir filter
G030078Air Cleaner Element (Engine) SecondaryAir filter
G30070Air Cleaner Element (Engine) PrimaryAir filter
GM100703Element, PrimaryAir filter
GM100704Element, SafetyAir filter
GM94203Heavy Duty Air CleanerAir filter
P-130D-001Air FilterAir filter
RE554812Filter ElementAir filter
22-4944112V/75A Alternator Standard GroundAlternator
22-49578Alternator 14 Volt 75 Amp Standard Ground (includes keys 2-3)Alternator
22-4958Alternator 28 Volt 50 Amp Standard GroundAlternator
22-49584Alternator 28 Volt 50 Amp IsolatedAlternator
22-49586Alternator 50 Amp Standard GroundAlternator
22-49587Alternator 14 Volt / 75 Amp Isolated Ground (includes keys #8-9)Alternator
32910Alternator, engineAlternator
AH137883ALTERNATOR (12V, 95A)Alternator
AH165975ALTERNATORAlternator
AT173624Alternator 12 Volt 65 AmpAlternator
AT387574ALTERNATORAlternator
DZ123153ALTERNATORAlternator
RE509080ALTERNATOR (12V, DENSO)Alternator
RE533516ALTERNATORAlternator
RE533653ALTERNATORAlternator
RE533654ALTERNATORAlternator
RE537146ALTERNATOR (28V, 50A) (3142)Alternator
RE537508ALTERNATORAlternator
RE540412ALTERNATOR (14V, 75A) (3148)Alternator
RE540413ALTERNATOR (28V, 50A) (3149)Alternator
RE554472(12V, 200A) (31AR)Alternator
RE555751ALTERNATORAlternator
RE558675ALTERNATORAlternator
RE558676ALTERNATORAlternator
RE558678ALTERNATORAlternator
RES58675ALTERNATOR (24V, 60A)Alternator
RM100225ALTERNATOR (REMAN FOR RE537146) (24 V, 50 A) (3104)Alternator
SE501342ALTERNATOR (REMAN FOR AH137883) (12V, 95A)Alternator
SE501343ALTERNATOR (REMAN FOR AH165975) (12V, 120A) (3103)Alternator
SE501838ALTERNATOR (REMAN FOR AT387574) (24V, 100A) (3152)Alternator
SE502561ALTERNATOR (REMAN FOR RE537508)Alternator
SE502563ALTERNATORAlternator
SE502626ALTERNATOR (REMAN FOR RE533516) (12V, 75A) (3138)Alternator
SE502627ALTERNATOR (REMAN FOR RE533653) (12V, 95A) (3140)Alternator
SE502628ALTERNATOR (REMAN FOR RE533654) (12V, 120A) (3141)Alternator
TY24322Alternator 24V/45 AmpAlternator
RE536402SHORT BLOCK ASSEMBLYAssembly
H144094Voltage RegulatorAvr
RE533942RegulatorAvr
RE567824Regulator (Not Shown)Avr
DKA344JESBaterías estándar (2), 12 V con 1700 A para arranque en frío, reserva nominal de 176 minutosBattery
100-024BeltBelt
100-085BeltBelt
33005Belt, fan/alternatorBelt
40-09504Drive Belt, Poly-V 28 mm x 1523 mmBelt
DZ112758(LGTH=1565 mm) (24GY)Belt
DZ115812FAN BELT (LGTH = 1680 mm)Belt
DZ117268FAN BELT (LGTH = 1530 mm)Belt
DZ118265FAN BELTBelt
DZ118558FAN BELTBelt
DZ118559FAN BELTBelt
DZ118560FAN BELTBelt
DZ118562FAN BELTBelt
DZ118563FAN BELTBelt
DZ118564FAN BELTBelt
DZ118606FAN BELTBelt
DZ118648FAN BELTBelt
DZ118649FAN BELTBelt
DZ118650FAN BELTBelt
DZ118652FAN BELTBelt
DZ118654FAN BELTBelt
DZ118768(LGTH=1535 mm) (24GR)Belt
DZ119014(LGTH=2335 mm) (24HL)Belt
DZ119059FAN BELTBelt
DZ119060FAN BELT (LGTH = 1555 mm)Belt
DZ119061FAN BELT (LGTH = 1540 mm)Belt
DZ119385FAN BELT (LGTH = 1650 mm)Belt
DZ119477FAN BELT (LGTH = 1565 mm)Belt
DZ119478FAN BELT (LGTH = 1570 mm)Belt
DZ119515FAN BELTBelt
DZ119522FAN BELTBelt
DZ119530FAN BELT (LGTH = 1675 mm)Belt
DZ119970(LGTH=1550 mm) (24HA)Belt
DZ124645FAN BELTBelt
F1000000005BeltBelt
GM66704-1Fan Belt (12V)Belt
GM66704-2Fan Belt (24V)Belt
JDG1341Belt Tension GaugeBelt
JDG1520Belt Tension Tool (alternate method for engines without auxiliary drive)Belt
R123439Drive Belt, LP-MP445D (non-turbo)Belt
R123440Drive Belt, LP-M445T-H (with turbo)Belt
R123451Drive Belt, M1064H, NL1064H1 (with turbo - all)Belt
R123454Drive Belt, NL668T2 (with turbo)Belt
R123457Drive Belt LP-MP668T-H (with turbo, formerly #R123464)Belt
R123461Drive Belt, L-M-NL1064D (non-turbo)Belt
R123462Drive Belt, NL445T1-T2 (with turbo)Belt
R123463Drive Belt, NL445D1 (non-turbo)Belt
R500277FAN BELTBelt
R523124V-BeltBelt
R524006V-BeltBelt
R525434FAN BELT (LGTH = 2180 mm)Belt
R525435FAN BELT (LGTH = 2190 mm)Belt
R533596FAN BELTBelt
RE518097Belt TensionerBelt
RE70536Belt TensionerBelt
T428692FAN BELT (LGTH = 1665 mm)Belt
T428712(LGTH=2400 mm) (24GS)Belt
T428820FAN BELT (LGTH = 1580 mm)Belt
T428825FAN BELTBelt
T429109FAN BELT (LGTH = 1660 mm)Belt
SE501794COMPLETE BLOCK ASSEMBLY (without auxilary drive may not be as illustrated. Includes cylinder head with valves and rocker arm assembly, balancer shafts, oil pump assembly, complete gasket kit with front and rear seals)Block assembly reman
SE501795COMPLETE BLOCK ASSEMBLY (auxiliary drive may not be as illustrated. Includes cylinder head with valves and rocker arm assembly, balancer shafts, oil pump assembly, complete gasket kit with front and rear seals)Block assembly reman
SE503065AC COMPRESSOR (REMAN FOR AH169875) (12V, 10PA) (7427, 7414)Compressor
F100-570CONTROL BOX ASSEMBLYControl box
SE502802CONTROLLER (REMAN FOR RE526588) (24V/12V, LEVEL 16) (16A5)Controller
100-037Coolant FilterCoolant filter
100-060Coolant FilterCoolant filter
F1000000004Coolant FilterCoolant filter
5070MEngineEngine
5080GEngineEngine
5080MEngineEngine
5080REngineEngine
5090GEngineEngine
5090MEngineEngine
5090REngineEngine
5100MEngineEngine
5100REngineEngine
M-RE527298Engine Overhaul Non-Cert, T1, T2Engine
M-RE527299Engine Overhaul Non-Cert, T1, T2Engine
R116466BushingEngine
R119874BushingEngine
R132518PlateEngine
R26650Dowel PinEngine
R48685Dowel PinEngine
RE508185Drain PlugEngine
T18891PlugEngine
F100-790ENGINE OPERATING PANEL ASSEMBLYEngine operating panel
F100-680ENGINE & RADIATOR ASSEMBLYEngine radiator
20-00002Pint - Part Number...............20-00002Fluid
20-000031/2 gallon - Part Number.....20-00003Fluid
22252050IR XHP605 55 Gal. (208 litres)Fluid
22252068IR XHP605 220 Gal. (836 litres)Fluid
22252076IR XHP605 compressor fluid, 5 gal. (19.0 Litre)Fluid
22252100XHP405 55 Gal. (208 litres)Fluid
22252118IR XHP1001 220 Gal. (836 litres)Fluid
22252126IR XHP405 compressor fluid, 5 gal. (19.0 Litre)Fluid
24952Jug, overflow 2.5 qtFluid
35300516IR XHP1001 55 Gal. (208 litres)Fluid
35612738IR XHP1001 compressor fluid, 5 gal. (19.0 Litre)Fluid
36866903Engine Oil (55 gal)Fluid
36875938Engine Oil (5 gal)Fluid
36899698IR Pro-Tec 1 gal. (3.8 litre)Fluid
36899706IR Pro-Tec 5 Gal. (19.0 litres)Fluid
36899714IR Pro-Tec 55 Gal. (208 litres)Fluid
36899722IR Pro-Tec 220 Gal. (836 litres)Fluid
54480918Engine Oil, 1 gal. (3.8 Litre)Fluid
G122208Clarke Eng Fluid - 5 galFluid
G122209Clarke Eng Fluid -1 galFluid
PT507John Deere Multi-Purpose GreaseFluid
TY22041John Deere ENGINE BREAK-IN OIL (SAE 10W-30)Fluid
TY6333JD Moly High Temp GreaseFluid
100-026Fuel FilterFuel filter
100-045Fuel FilterFuel filter
24-51003Fuel Filter without Drain ValveFuel filter
24-51004Fuel Filter with Plastic Drain ValveFuel filter
24-51005Fuel Filter with Metal Drain ValveFuel filter
24-52259Fuel filterFuel filter
25-1639Fuel FiltersFuel filter
26379Vent, plastic fuel 1.00 IDFuel filter
29877Heater, fuel filterFuel filter
32911Filter, fuel - primary and secondaryFuel filter
33023Filter, fuel - finalFuel filter
33024Filter, fuel - primaryFuel filter
36534659Engine Fuel Filter ElementFuel filter
65631Gauge, fuel - elec w/lightFuel filter
CO2775Element, Fuel Water SeparatorFuel filter
CO2776Element, Fuel Filter PrimaryFuel filter
DZ115390SECONDARY FUEL FILTERFuel filter
DZ115391PRIMARY FUEL FILTERFuel filter
DZ128543PRIMARY FUEL FILTERFuel filter
F1000000003Fuel FilterFuel filter
G021199Element, Fuel Filter PrimaryFuel filter
GM50006Fuel FilterFuel filter
GM50074Fuel Filter (primary)Fuel filter
P-205-003Fuel FilterFuel filter
RE509031Filter ElementFuel filter
RE509032Filter ElementFuel filter
RE509036Fuel FilterFuel filter
RE509208Filter Element (also order R113565)Fuel filter
RE5092082Fuel filterFuel filter
RE516999ScreenFuel filter
RE519031Fuel filterFuel filter
RE521537Fuel Filter AssemblyFuel filter
RE521538Filter ElementFuel filter
RE521539FilterFuel filter
RE521540Fuel FilterFuel filter
RE521541Fuel FilterFuel filter
RE522868Fuel FilterFuel filter
RE522878Fuel filterFuel filter
RE526834Filter KitFuel filter
RE541922PRIMARY FUEL FILTERFuel filter
RE544394FINAL FUEL FILTERFuel filter
RG11830AFinal Fuel Filter/Water Separator BaseFuel filter
RG11830CReplace Final Fuel Filter/Water SeparatorFuel filter
RG9091Final Fuel Filter AssemblyFuel filter
RG12000Injection Pump Drive Gear RemovalFuel pump
RG12002Injection PumpFuel pump
RG12022Fuel Supply Pump Push RodFuel pump
RG12036JDG1559 Injection Pump Timing PinFuel pump
RG4906Fuel injection pump model and serial information on serial number plateFuel pump
RG7629BInjection Pump Timing Marks A—Timing Mark on Front Plate B—Timing Mark on Injection Pump FlangeFuel pump
RG7722Fuel Injection PumpFuel pump
RG9051Fuel Supply Pump LinesFuel pump
0000I00Fuel SolenoidFuel solenoid
11-21011GasketGasket
11-31012GasketGasket
11-31031Gasket, Turbo Oil ReturnGasket
11-31094GasketGasket
11-31099GasketGasket
11-31401Gasket, K26 Turbo MountingGasket
11-31615GasketGasket
11-79501Gasket,Oil Filler & Block-Off Plate MtgGasket
14-31042GasketGasket
18648Cap, fuel fill with gasketGasket
19238Gasket, fuel fillGasket
22323Gasket, fuel sending unitGasket
25-11017GasketGasket
29-09400Gasket Set (Engine Overhaul, includes all keys)Gasket
29-09402Gasket Set (Engine Overhaul, includes all keys)Gasket
33265Gasket, 3.0 exhaust pipe flangeGasket
4194-21011GasketGasket
44-31031GasketGasket
44-31401GasketGasket
65626Gasket—Oil Filler CapGasket
65629Cylinder Head Assembly consisting of IA-C Cylinder Head, EA45 Exhaust Valve Spring, EA57 Valve Spring Gasket, EA65 Exhaust Valve, 65562 Valve Spring Washers, EA38 Valve Spring Cup, EA34 Valve Spring WasherGasket
CAMSET000301CAM(WITH BOLT,GASKET)Gasket
FP-RE37715-WSGasket Set, Complete Overhaul w/Front and Rear SealsGasket
M-RE532713Gasket Set - OverhaulGasket
M-RE532842Gasket Set - Cyl HeadGasket
M-RE536967Gasket Set - Cyl HeadGasket
PG219SGasket Set, In-frame OverhaulGasket
PG301PSGasket Set, Oil PanGasket
R108612GasketGasket
R108730GasketGasket
R108848GasketGasket
R116515Engine Cylinder Head GasketGasket
R116516Engine Cylinder Head GasketGasket
R123226Gasket, Water By-pass TubeGasket
R123345Gasket, Thermostat HousingGasket
R123352GasketGasket
R123353GasketGasket
R123354Gasket, Engine Oil PanGasket
R123417Gasket, Water PumpGasket
R123501GasketGasket
R123504Gasket, Remote Oil Filter AdapterGasket
R123525GasketGasket
R123542Gasket, Rocker Arm Cover MountingGasket
R123543Gasket, Rocker Arm CoverGasket
R123570GasketGasket
R123572GasketGasket
R123676GasketGasket
R125670GasketGasket
R133893GasketGasket
R134465GasketGasket
R135896GasketGasket
R136495GasketGasket
R136516Gasket, Timing Gear CoverGasket
R47693GasketGasket
R500374GasketGasket
R501428GasketGasket
R505174GasketGasket
R521158Turbo GasketGasket
R521493GasketGasket
R522690GasketGasket

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Filters for this engine

  • Air filter: John Deere AL204809 John Deere AT390262 John Deere AT390261 John Deere AL119839 John Deere AL150285 John Deere AL150288 John Deere RE508969 John Deere F052645
  • Fuel filter (primary): Kohler GM50006 Kohler 336661 Kohler GM48727 Kohler GM50074 John Deere AT274723 John Deere RE62418 John Deere RE62419 John Deere RE509208
  • Oil filter: Kohler GM32809 Kohler 360031 John Deere RE519987 John Deere MIU800650 John Deere DZ118286 Donaldson P550779 Donaldson P502051 Donaldson P551352

Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.

Also used in

12
  • Broce Broom RJ350 — Sweeper
  • John Deere 210L — Backhoe Loader
  • John Deere 5080R — Tractor
  • John Deere 5080RN — Tractor
  • John Deere 5090R — Tractor
  • John Deere 5090RN — Tractor
  • John Deere 5100R — Tractor
  • John Deere 5100RN — Tractor
  • John Deere 6320SE — Tractor
  • John Deere 6420SE — Tractor
  • John Deere 6602 — Combine
  • John Deere A400 — Windrower

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the John Deere 4045HF285K?

The John Deere 4045HF285K engine has an oil capacity of 13.9 liters.

What is the displacement of the John Deere 4045HF285K?

The John Deere 4045HF285K has a displacement of 4.5 liters with 4 cylinders.

Which generators use the John Deere 4045HF285K engine?

The John Deere 4045HF285K powers 1 generator set(s), including Kohler 125REOZJG.

What oil filter does the John Deere 4045HF285K use?

The John Deere 4045HF285K uses oil filter part numbers Kohler GM32809, Kohler 360031, John Deere RE519987.

What fuel filter does the John Deere 4045HF285K use?

The John Deere 4045HF285K uses fuel filter part numbers Kohler GM50006, Kohler 336661, Kohler GM48727.

What air filter does the John Deere 4045HF285K use?

The John Deere 4045HF285K uses air filter part numbers John Deere AL204809, John Deere AT390262, John Deere AT390261.

What is a common problem with the John Deere 4045HF285K engine?

A commonly reported issue on generators using the John Deere 4045HF285K is: Emergency Stop. Fix: Reset the emergency stop switch..