HomeEnginesJohn Deere 3029HFG03

John Deere 3029HFG03 Engine

The John Deere 3029HFG03 is a 2.9 L turbocharged & aftercooled engine rated at 1800 rpm. It powers generator sets from Generac, including the MMG35DF4 and MMG55DF4. It holds 10.4 L (2.7 gal) of oil and 17 L (4.5 gal) of coolant.

Also known as: John Deere 3029HFG03

Part of the John Deere 3029 engine family — 16 variants share parts & fitment.

2.9 L
Displacement
1800 rpm
Rated speed
10.4 L
Oil capacity

Engine specifications

Oil capacity10.4 L
Coolant capacity17.0 L
Displacement2.9 L
AspirationTurbocharged & Aftercooled
Rated speed1800 rpm

Common problems

15
  • Unit will not start in AUTO with 2-wire start signal.
    Cause: See if screen says unit not activated.
  • Unit was running and shuts down, attempts to restart. RPM SENSE LOSS
    Cause: Check the LEDs/Screen for alarms.
    Fix: Clear alarm and remove household loads from the generator. Put back in AUTO and restart. If problem returns, contact Independent Authorized Servicing Dealer to investigate possible fuel issue.
  • Unit shuts down during operation. HIGH TEMPERATURE
    Cause: Check ventilation around the intake, exhaust and rear of generator.
    Fix: Contact s Independent Authorized Servicing Dealer if no obstruction is found.
  • Unit running in AUTO but no power in house.
    Cause: Check Generator Disconnect circuit breaker.
    Fix: Contact Independent Authorized Servicing Dealer if Generator Disconnect circuit breaker is in the ON position.
  • Unit consumes large amounts of oil.
    Cause: 1) Oil tank is over filled with oil. 2) Engine breather defective. 3) Improper type or viscosity of oil. 4) Damaged gasket, seal or hose.
    Fix: 1) Adjust oil to proper level. 2) * 3) See Engine Oil Recommendations. 4) Check for oil leaks.
  • Undervoltage RED Unit shuts down during operation or starting. 1056 VSCF
    Fix: Check the LEDs/Screen for alarms. The generator output voltage is too low. Probable causes are: 1) The load is too large. Remove load and attempt to restart unit. 2) Alternator or AVR damage. Contact Independent Authorized Servicing Dealer.
  • Speed mismatch RED Unit shuts down during Operation or starting. 1066 VSCF
    Fix: Check the LEDs/Screen for alarms. Probable causes are: 1) Fuel problem (pressure loss). Check fuel supply and attempt to restart unit. 2) Large overload. Remove load and attempt to restart unit. 3) Throttle or engine problem. Contact Independent Authorized Servicing Dealer.
  • Shutdown indicator LED.
    Fix: Resolve by resolving shutdown condition.
  • Phase Error RED Unit shuts down during starting. 1055 VSCF
    Fix: Check the LEDs/Screen for alarms. An incorrect voltage and frequency has been detected during starting. Probable causes are: 1) Alternator damage. Contact Independent Authorized Servicing Dealer. 2) Generator has started into a severe load. Manually operate generator breaker and try to restart unit. If problem persists, remove load and attempt to restart unit again. 3) The engine may not be reaching its prescribed speed. Proceed as follows: •Verify stepper motor is moving and linkage is free. •Verify stepper motor is plugged in. •Verify gas pressure is within specified limits.
  • Overvoltage RED Unit shuts down during operation or starting. 1057 VSCF
    Fix: Check the LEDs/Screen for alarms. Probable causes are: 1) The generator has been overloaded. Remove load and attempt to restart unit. 2) Generator has started into a severe load. Manually operate generator breaker and try to restart unit. If problem persists, remove load and attempt to restart unit again.
  • Overload RED Unit shuts down during operation. 1049 VSCF
    Fix: Check the LEDs/Screen for alarms. Generator output is shorted or severely overloaded. Identify and clear the overload, and then restart.
  • Overfrequency RED Unit shuts down during operation. 1065
    Fix: Check the LEDs/Screen for alarms. Probable causes are: 1) Overload. Remove load and attempt to restart unit. 2) RPM sensor has failed. Contact Independent Authorized Servicing Dealer. 3) Stepper motor problem. Contact Independent Authorized Servicing Dealer.
  • Output voltage is low/high.
    Fix: Voltage calibration incorrect. Contact Independent Authorized Servicing Dealer.
  • No AC output from generator.
    Cause: 1) Main line circuit breaker is in the OFF (or OPEN) position. 2) Generator internal failure.
    Fix: 1) Reset circuit breaker to ON (or CLOSED). 2) *
  • Lug Door Open indicator LED.
    Fix: Resolve by closing lug-box door. If condition remains unresolved, inspect lug-box door safety switch for proper operation.

Compiled from service & troubleshooting documentation across every generator set that uses the John Deere 3029HFG03.

Service intervals

30
ItemActionHoursMonthsNotes
Engine Oil (Isuzu)Change50 hrFirst service — First 50 hours (break-in period)
Oil Filter Element ReplacementReplace500 hrFirst service — Isuzu, first 50 hours and every 500 hours
Engine Oil and Oil Filter (John Deere)Change500 hr12 moFirst service — First 100 hours break-in, factory fill; do not exceed 100 hours with break-in oil
Check Oil Vapor Recirculation System/Non-Return ValveCheck250 hrJohn Deere engine
Engine Oil (Isuzu, MMG25IF4)Change250 hrEvery 250 hours, MMG25IF4 only
Change Engine Oil and Replace Oil FilterChange500 hr12 moFirst service — John Deere; decrease to every 250 hours if not using John Deere Plus 50 II oil
Engine Oil (Isuzu, MMG45IF4)Change500 hrEvery 500 hours, MMG45IF4 only; every 250 hours instead if harsh environment or fuel quality questioned
Fuel Filter Elements (Isuzu)Replace500 hrEvery 500 hours (every 250 hours if harsh environment/fuel quality questioned)
Fuel Filter Elements (John Deere)Replace500 hr12 mo
Replace Engine OilChange500 hrFirst service — Isuzu, every 500 hours (or every 250 hours if harsh environment/fuel quality questioned)
Replace Fuel Filter ElementsReplace500 hr12 moJohn Deere engine
Replace Oil Vapor Recirculation FilterReplace500 hr12 moJohn Deere engine
Service BatteryOther500 hr12 moJohn Deere engine
Water Sedimenter Element (Isuzu)Clean500 hrEvery 500 hours (every 250 hours if harsh environment/fuel quality questioned)
Air Cleaner Elements (John Deere)Replace2000 hr
Air Filter Element (Isuzu)Replace2000 hr
Alternator and Fan Belts (John Deere)Replace2000 hr
Check Generator Drive Plate TorqueCheck2000 hrIsuzu engine
Lubricate Leveling JacksLubricate2000 hrIsuzu engine
Replace Air Cleaner ElementsReplace2000 hrJohn Deere engine
Replace Air Filter ElementReplace2000 hrIsuzu engine
Replace Alternator and Fan BeltsReplace2000 hrJohn Deere engine
Replace Fan BeltReplace2000 hrIsuzu engine
Test ThermostatsTest2000 hrJohn Deere engine
Diesel Particulate Filter (DPF)Other3000 hrExpected service interval at least 3,000-4,500 hours depending on engine power/operating conditions; serviced by authorized provider only
Exhaust Filter (DPF) ServiceOther3000 hrExpected service interval at least 3,000-4,500 hours based on engine power/operating conditions; serviced by authorized provider only
Reset Maintenance Alarm IntervalsOther3000 hrPower Zone controller maintenance alarm 3
Jack Maintenance (lubricate gearing/handle)Lubricate12 moPerform annually
Leveling JacksLubricate12 moAnnually
Trailer Wheel Bearings LubricationLubricate12 moMinimum every 12 months or 12,000 miles (19,312 km)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

24
TypeItemValueUnitCondition
OtherAir Filter Minder Gauge Replacement Threshold20in. H2O
OtherRadiator Cap Coolant Fill Clearance3/4in.below filler neck (approx 2 cm)
PressureLoss-of-oil-pressure shutdown verification threshold5psi (34 kPa)shut engine down immediately if pressure does not read this value within 5 seconds of restart
PressureLow Oil Pressure Shutdown Threshold20psi
PressureMaximum trailer tire pressure65psi
PressureNormal Operating Oil Pressure35-80psi
PressureOil Pressure Gauge Range0-100psi
PressureOil Pressure Shutdown Confirmation Threshold5psiif not attained within 5 seconds of restart, shut engine down immediately
TemperatureCoolant Temperature Gauge Range150-250°F
TemperatureHigh Coolant Temperature Shutdown Threshold230°F
TemperatureHigh coolant temperature shutdown230°F (110°C)stop engine immediately at or above this temperature
TemperatureNormal Operating Coolant Temperature180-200°Faverage ambient air temperature of 70°F (21°C)
TorqueGenerator Drive Plate Bolts30ft-lbs
TorqueGenerator Drive Plate Bolts40ft-lbs
TorqueGenerator drive plate bolts - MMG25IF430ft-lbs (40 Nm)
TorqueGenerator drive plate bolts - MMG35DF440ft-lbs (54 Nm)
TorqueGenerator drive plate bolts - MMG45IF430ft-lbs (40 Nm)
TorqueGenerator drive plate bolts - MMG55DF440ft-lbs (54 Nm)
TorqueTrailer wheel lug nuts, first pass20-25ft-lbs (27-33 Nm)first pass, star sequence
TorqueTrailer wheel lug nuts, second pass50-60ft-lbs (67-81 Nm)second pass, star sequence
TorqueTrailer wheel lug nuts, third pass90-120ft-lbs (122-162 Nm)third pass, star sequence
VoltageBattery Voltage Gauge Range0-50V
VoltageNormal Battery Reading12-14V12 volt systems, engine running
VoltageNormal Battery Reading24-26V24 volt systems, engine running

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Engine oilJohn Deere Plus 50 II (John Deere engine)Refer to OEM engine manual for viscosity grade by season/climate
FuelUltra-low-sulfur diesel379.0 L (100 gal total, 90 gal usable)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

4
Checking Generator Drive Plate Torque maintenance
  1. Disconnect engine starting battery
  2. Remove generator fan guard
  3. Tighten each drive plate bolt to specification in Table 4
  4. Install generator fan guard
  5. Connect battery
Resetting the Maintenance Alarms maintenance
  1. With unit shut down, move Control Power switch to ON
  2. Press any directional arrow to enter maintenance screens
  3. Press Enter and Stop/Reset simultaneously to open Configuration menu
  4. Move cursor down to Maintenance group
  5. Press right arrow to access sections and highlight Maintenance section
  6. Press right arrow to access parameters and highlight the alarm to reset
  7. Press Enter to select editable parameter, highlight Reset
  8. Press Enter to reset the selected alarm
  9. Repeat for additional alarms
  10. Press and hold Enter for five seconds to save changes
Towing the Unit - Wheel Lug Torque maintenance

Tools: Torque wrench

  1. Start all lug nuts by hand.
  2. First pass: tighten to 20-25 ft-lbs (27-33 Nm).
  3. Second pass: tighten to 50-60 ft-lbs (67-81 Nm).
  4. Third pass: tighten to 90-120 ft-lbs (122-162 Nm).
  5. Re-torque lug nuts in sequence after first road use.
Manual Starting of the Unit operation

⚠ Running engines produce carbon monoxide - asphyxiation hazard

  1. Move Control Power switch to ON
  2. Verify controller enters Stop mode/Home screen
  3. Press Engine Start button in Manual mode

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the John Deere 3029 family

89
Part #DescriptionCategory
010419Air filterair_filter
RE509106ALTERNATOR (14V, 65A) (3132)alternator
RE544045ALTERNATOR (28V, 50A) (3131)alternator
SE501346ALTERNATOR (REMAN FOR AL81436 OR AL207585) (14V, 55A)alternator
SE501372ALTERNATOR (REMAN FOR TY6686) (12V, 78A)alternator
SE501828(REMAN FOR RE533653) (3140)alternator
SE501835ALTERNATOR (REMAN FOR RE509106) (14V, 65A) (3132)alternator
991990Battery disconnecterbattery
010422Battery servicebattery_service
010421Beltbelt
R73784FAN BELT (LGTH = 1340 mm)belt
R73785FAN BELT (LGTH = 1465 mm)belt
R97939FAN BELT (LGTH = 1320 mm)belt
RE55793FAN BELT (LGTH = 1300 mm)belt
T20334FAN BELT (LGTH = 1219 mm)belt
T23526FAN BELT (LGTH = 1257 mm)belt
T24473FAN BELT (LGTH = 1295 mm)belt
010420Coolant and filtercoolant
791278Biological hydraulic fluid Alt. 1fluid
99000-25010Grease Afluid
010418Fuel filterfuel_filter
RE60021FUEL FILTERfuel_filter
RE62418FUEL FILTERS (35C4)fuel_filter
SE501101NOZZLE (REMAN FOR RE48786)injector
SE501177NOZZLE (REMAN FOR RE515684) (16QN) (16QP) (16SW) (16SV) (16WL)injector
010417Oil and filteroil
DZ118286OIL FILTERoil_filter
RE519626ENGINE OIL FILTERoil_filter
RE533026FUEL FILTERS (35K6)oil_filter
T19044OIL FILTER (FOR EXPORT)oil_filter
791275Sound Power level CA141 105other_service
DZ102006SHORT BLOCK ASSEMBLYother_service
R110081FAN PULLEY (OD = 154 mm)other_service
R110450CRANKSHAFT PULLEY AND DAMPER (OD = 174 mm)other_service
R113425CRANKSHAFT PULLEY AND DAMPER (OD = 174 mm)other_service
R117011CRANKSHAFT PULLEY AND DAMPER (OD = 140 mm)other_service
R120262CRANKSHAFT PULLEY AND DAMPER (OD = 174 mm)other_service
R133067CRANKSHAFT PULLEY AND DAMPER (OD = 146 mm)other_service
R501213CRANKSHAFT PULLEY AND DAMPER (OD = 174 mm)other_service
R501222CRANKSHAFT PULLEY AND DAMPER (OD = 140 mm)other_service
R501223CRANKSHAFT PULLEY AND DAMPER (OD = 174 mm)other_service
R547151CRANKSHAFT PULLEY AND DAMPER (OD = 171 mm) (1346)other_service
R76979FAN PULLEY (OD = 135 mm)other_service
R87148FAN PULLEY (OD = 172 mm)other_service
RE502325SHORT BLOCK ASSEMBLYother_service
RE535720SHORT BLOCK ASSEMBLYother_service
RE59031CRANKSHAFT PULLEY AND DAMPER (OD = 174 mm)other_service
SE501484COMPLETE BLOCK ASSEMBLYother_service
SE501488COMPLETE BLOCK ASSEMBLYother_service
SE501571CONNECTING ROD (REMAN FOR DZ104739) (4813)other_service
SE501572CONNECTING ROD (REMAN FOR RE501675)other_service
SE501573CONNECTING ROD (REMAN FOR RE501675)other_service
DZ108524CRANKSHAFT PULLEY AND DAMPERT (OD=171mm) (1346)pump
99000-31110Sealant Bsealant
010423Spark plugsspark_plug
09912-34510Special tool (A)special_tool
09913-60910Special tool (B)special_tool
09913-61510Special tool (A) for main shaft hub removalspecial_tool
09913-84510Special tool (A) for input shaft oil seal retainerspecial_tool
09922-85811Special tool (A) for upper case and shifter assembly removalspecial_tool
DZ11008STARTER MOTOR (12 V, 3.4 KW) (3075)starter
DZ110081STARTERstarter
DZ110082STARTER MOTOR (24 V, 4 KW)starter
DZ129200STARTERstarter
RE501693STARTER MOTOR (12 V, 2.5 KW)starter
RE501713STARTER MOTOR (12 V, 2.6 KW)starter
RE507670STARTER MOTOR (12 V, 3.1 KW)starter
RE515688STARTERstarter
RE516157STARTER MOTOR (12 V)starter
RE519568STARTER MOTOR (12 V, 2.8 KW)starter
RE523502STARTERstarter
RE528929STARTERstarter
RE540300STARTERstarter
RE546868STARTERstarter
RE552251STARTER MOTOR (24V, 3.5KW) (30CA)starter
RE552252STARTER MOTOR (24V) (30CB)starter
RE62916STARTER MOTOR (12 V)starter
SE501400STARTER (REMAN FOR RE62916) (12V, 2.5KW)starter
SE501401(REMAN FOR RE540301) (3005)starter
SE501402(REMAN FOR RE540300) (3007)starter
SE501427STARTER (REMAN FOR DZ110081) (12V, 3.4KW)starter
SE501851(REMAN FOR DZ110081 OR RE507670) (12V, 3.4KW) (3075)starter
SE501852ALTERNATOR (REMAN FOR RE516157) 12V, 3.2KWstarter
SE501865STARTER (REMAN FOR RE501693) (12V, 2.5KW)starter
SE501869STARTER (REMAN FOR RE519568) (12 V, 3.2 KW) (3085)starter
SE502286(REMAN FOR DZ110082) (24V, 4KW) (3092)starter
99000-32020Thread lock cement Cthread_lock_cement
SE501634TURBOCHARGER (REMAN FOR RE70036)turbocharger
SE502214TURBOCHARGER (REMAN FOR RE518226) (65V6)turbocharger

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

What is the oil capacity of the John Deere 3029HFG03?

The John Deere 3029HFG03 engine has an oil capacity of 10.4 liters.

What is the displacement of the John Deere 3029HFG03?

The John Deere 3029HFG03 has a displacement of 2.9 liters.

Which generators use the John Deere 3029HFG03 engine?

The John Deere 3029HFG03 powers 2 generator set(s), including Generac MMG35DF4, Generac MMG55DF4.

What is a common problem with the John Deere 3029HFG03 engine?

A commonly reported issue on generators using the John Deere 3029HFG03 is: Unit will not start in AUTO with 2-wire start signal.. Cause: See if screen says unit not activated..