The Hercules G4800 series Natural Gas engines is a 6-cylinder natura] aspirated, turbocharged, and turbocharged with after cooling engine rated at 9197 rpm. It powers generator sets from Hercules, including the GTA4800.
Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|
| Air filter | | | — | 125 hr | |
| Fuel filter | | | — | 125 hr | |
| Oil filter | | | — | 125 hr | |
| Battery | | | — | 3000 hr | |
| Belt | | | — | 125 hr | |
| Coolant | | | — | 500 hr | |
| Oil | | | 40-3104703 | 500 hr | Amazon eBay |
| Spark plug | | | — | 500 hr | |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Common questions
Which generators use the Hercules G4800 series Natural Gas engines engine?
The Hercules G4800 series Natural Gas engines powers 1 generator set(s), including Hercules GTA4800.
How often should you change the oil in the Hercules G4800 series Natural Gas engines?
The Hercules G4800 series Natural Gas engines oil change interval is every 500 hours.
What is a common problem with the Hercules G4800 series Natural Gas engines engine?
A commonly reported issue on generators using the Hercules G4800 series Natural Gas engines is: CIRCUIT BOARD CONNECTOR PIN VOLTAGE does not meet specified range. Fix: Check and ensure that the circuit board connector pin voltage is within the specified range (114-126 VDC for 572 602, 572 612 'E', 143-157 VDC for 572 603, 572 613 'E', and 143-157 VDC for 572 604, 572 614 'G', 143-157 VDC for 572 606, 572 616 'G') at 500 RPM. If out of range, check the circuit board and replace if necessary..