Hatz 4H50 TI Engine
The Hatz 4H50 TI is a 1.95 L 4-cylinder turbocharged with charge air cooling engine rated at 2800 rpm, producing up to 177.5 kW. It powers generator sets from Hatz, including the 4H50 and 4H50TI. It holds 7 L (1.8 gal) of oil and 13.2 L (3.5 gal) of coolant.
Also known as: HATZ 4H50 TI
Part of the Hatz 4H50 engine family — 2 variants share parts & fitment.
Engine specifications
| Oil capacity | 7.0 L |
|---|
| Coolant capacity | 13.2 L |
|---|
| Displacement | 1.952 L |
|---|
| Cylinders | 4 |
|---|
| Aspiration | Turbocharged with charge air cooling |
|---|
| Rated speed | 2800 rpm |
|---|
| Gross power | 177 kW |
|---|
Generator sets powered by this engine
2
Common problems
15- The engine does not start or does not start immediately, but can be turned with the starter
Cause: Hydraulic load too high (especially with multiple hydraulic pumps)
Fix: Reduce the hydraulic load – if possible - The starter does not switch on and the engine does not turn
Cause: Irregularities in the electrical equipment: Battery and/or other cable connections are incorrectly connected
Fix: Check the electrical equipment and its components or contact Hatz service - Engine becomes very hot. The engine temperature indicator lights up
Cause: Contamination in the entire area of the cooling air guides
Fix: Clean the cooling air area - Area affected: Low pressure fuel system 2 - 1
Cause: Maximum water level in the water separator reached
Fix: Drain water from the fuel prefilter - Area affected: Liquid cooling 3 - 1
Cause: Coolant level too low
Fix: Top up coolant - The engine loses power and speed, and black smoke emerges from the exhaust
Cause: Dirty air filter unit
Fix: Check the degree of dirt contamination of the air filter, and clean or renew it if necessary - Engine switches off spontaneously during operation
Cause: The tank ran out of fuel during operation
Fix: Fill with fuel - At low temperatures (engine does not start)
Cause: Oil is too viscous and causes a too low starter speed
Fix: Change the engine oil and oil filter; Add engine oil with a suitable viscosity class - Area affected: Pre-glow system 3 - 2
Cause: Glow plugs cabling faulty
Fix: Check the cabling - Area affected: Monitoring of indicator and control elements 1 - 1
Cause: Indicator(s) or cabling faulty
Fix: Check the function and cabling of the indicators - Area affected: Engine oil temperature/engine oil pressure 2 - 3
Cause: Engine oil pressure too high/too low
Fix: Check the oil level, top up the engine oil if required; Use engine oil with a suitable viscosity - Area affected: Air supply 1 - 3
Cause: Air filter is dirty
Fix: Service the air filter - The engine loses power and speed
Cause: Engine running due to a fault in the emergency run function (instrument box sends flashing signal)
Fix: Heed the flashing code table; Switch off the engine, wait at least 1 minute, then restart the engine. (This deletes minor errors) - Indicator for engine fault on the HATZ instrument box is flashing
Cause: Various errors in different assemblies
Fix: Use the flash code table to identify and eliminate errors - Area affected: Speed sensor system 1 - 2
Cause: Crankshaft or camshaft sensor cabling faulty
Fix: Check the cabling
Compiled from service & troubleshooting documentation across every generator set that uses the Hatz 4H50 TI.
Parts cataloged across the Hatz 4H50 family
6| Part # | Description | Category |
|---|
| 100-025-001 | Air Filter | Air filter |
| 100-075-001 | Belt | Belt |
| 100-060-001 | Coolant Filter | Coolant filter |
| 100-045-001 | Fuel Filter | Fuel filter |
| 100-030-001 | Oil Filter | Oil filter |
| 100-090-001 | Spark Plug | Spark plug |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
Aftermarket parts that fit this engine
3Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.
Common questions
What is the oil capacity of the Hatz 4H50 TI?
The Hatz 4H50 TI engine has an oil capacity of 7.0 liters.
What is the displacement of the Hatz 4H50 TI?
The Hatz 4H50 TI has a displacement of 1.952 liters with 4 cylinders.
Which generators use the Hatz 4H50 TI engine?
The Hatz 4H50 TI powers 2 generator set(s), including Hatz 4H50, Hatz 4H50TI.
What is a common problem with the Hatz 4H50 TI engine?
A commonly reported issue on generators using the Hatz 4H50 TI is: The engine does not start or does not start immediately, but can be turned with the starter. Cause: Hydraulic load too high (especially with multiple hydraulic pumps). Fix: Reduce the hydraulic load – if possible.