The General Motors 3.0L L4 is a 2.97 L 4-cylinder engine. It powers generator sets from Power Solutions International, including the 3.0 L. It holds 3.7 L (1.0 gal) of oil and 4 L (1.1 gal) of coolant.

Also known as: GM Powertrain 3.0L L4

Part of the General Motors 3.0L engine family — 2 variants share parts & fitment.

2.966 L
Displacement
4
Cylinders
3.7 L
Oil capacity

Engine specifications

Oil capacity3.7 L
Coolant capacity4.0 L
Displacement2.966 L
Cylinders4

Generator sets powered by this engine

1

Common problems

15
  • Unit Not In Auto LED 12
    Fix: Move the AUTO/OFF/MANUAL switch to the AUTO position for automatic starting.
  • Low Fuel LED 11
    Fix: Check fuel supply and replenish as required.
  • Press To Test Button 13
  • Overcrank LED 17
    Fix: Check for empty fuel tank, fuel leaks, or plugged fuel lines and correct as required. Check for dirty fuel filter and replace if necessary (See Maintenance section of Engine Manual). Check for dirty or plugged air filter and replace if necessary (See Maintenance section of Engine Manual).
  • No Engine Stop. 29
    Fix: Check Engine Start Timer setting. Check Engine Start Connections. Investigate why the Engine Control Switch was put in Manual. Contact your Dealer or Distributor for assistance.
  • No Engine Start. 28
    Fix: Check Engine Start connections. Investigate why the Engine Control Switch was put in Manual. Contact your Dealer or Distributor for assistance.
  • No AC Output Voltage. 27
    Fix: Verify output with another meter if ok check meter, if ok check meter fuses. Regulator fuse is blown. Replace fuse. Contact your Dealer or Distributor if voltage build-up causes fuse to blow. Check rotating rectifier for damaged diodes. Replace all diodes if any are failed.
  • Low Water Temp LED 8
  • Low Oil Pressure Pre-alarm LED 10
  • Low Oil Pressure LED 16
    Fix: Check oil level, lines and filters. If the oil system is okay but oil level is low, replenish.
  • Low Coolant Temperature LED 21
    Fix: Check for the following conditions: Coolant heater not connected to power supply. Check for blown fuse, open circuit breaker or disconnected heater cord and correct as required. Check for low-coolant level and replenish if required. Look for possible coolant leakage points and repair as required.
  • Low Battery LED 23
    Fix: Check electrolyte level and charger output or replace the battery.
  • High Engine Temp Pre-alarm LED 9
  • Fault LED on but no fault exists. Engine gauges show oil pressure, engine temperature, and frequency (speed) are within normal limits. 24
    Fix: Contact your Dealer or Distributor for service.
  • Engine will not crank. 26
    Fix: Check for the following conditions: Fault lamp on. Correct fault and reset control. Poor battery cable connections. Clean the battery cable terminals and tighten all connections. Discharged or defective battery. Recharge or replace the battery.

Compiled from service & troubleshooting documentation across every generator set that uses the General Motors 3.0L L4.

Parts cataloged across the General Motors 3.0L family

17
Part #DescriptionCategory
253107Element, Air Cleanerair_filter
4024TF281Fan Beltbelt
GM16132Belt, fan standardbelt
GM34935Fuel Filterfuel_filter
GM63809Fuel Filter (primary)fuel_filter
1259369GTManifoldsmanifold
GM16531Spark plugoil_filter
GM16703Filter, oiloil_filter
GM22171Spark plugoil_filter
GM38998Spark plugoil_filter
GM39428Belt, alternatoroil_filter
GM62309Element, air cleaneroil_filter
GM63750Oil Filteroil_filter
GM65427Belt, alternatoroil_filter
GM39458LCT Sendersensor
GM19726Thermostatspark_plug
GM79585--SThermostatthermostat

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

What is the oil capacity of the General Motors 3.0L L4?

The General Motors 3.0L L4 engine has an oil capacity of 3.7 liters.

What is the displacement of the General Motors 3.0L L4?

The General Motors 3.0L L4 has a displacement of 2.966 liters with 4 cylinders.

Which generators use the General Motors 3.0L L4 engine?

The General Motors 3.0L L4 powers 1 generator set(s), including Power Solutions International 3.0 L.

What is a common problem with the General Motors 3.0L L4 engine?

A commonly reported issue on generators using the General Motors 3.0L L4 is: Unit Not In Auto LED. Fix: Move the AUTO/OFF/MANUAL switch to the AUTO position for automatic starting..