| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Coolant heater(s) | Check | 8 hr | Daily | |
| Coolant level of radiators | Check | 8 hr | Daily | |
| Engine oil level | Check | 8 hr | Daily | |
| General set inspection | Inspect | 8 hr | Daily; check for oil, fuel, cooling and exhaust system leaks | |
| All hardware (fittings, clamps, fasteners) | Check | 100 hr | ||
| Battery charging system | Check | 100 hr | ||
| Battery electrolyte level | Check | 100 hr | ||
| Drive belts | Check | 100 hr | Visually check for wear or slippage; replace if hard or brittle | |
| Exhaust condensate trap | Drain | 100 hr | ||
| Generator air outlet | Check | 100 hr | ||
| Fan bearings (two) | Lubricate | 250 hr | 6 mo | |
| Radiator hoses | Inspect | 250 hr | 6 mo | Check for wear and cracks |
| Generator bearing (Frame 7 / Frame 8) | Lubricate | 500 hr | ||
| Generator insulation resistance | Test | 500 hr | ||
| Air cleaner | Check | 1000 hr | Replace as necessary | |
| Anti-freeze and DCA concentration | Check | 1000 hr | ||
| Crankcase breather | Clean | 1000 hr | ||
| Engine oil and filter | Change | 1000 hr | ||
| Fuel filter(s) | Drain | 1000 hr | ||
| Jacket Water & LTA cooling systems | Clean | 1000 hr | ||
| Jacket water coolant filters | Change | 1000 hr | ||
| Fuel filters | Change | 4000 hr |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Air gap (rotor to stator), normal | 0.3 | inch | |
| Clearance | Air gap (rotor to stator), normal | 7.5 | mm | |
| Clearance | Air gap (rotor to stator, Frame 8 removal), minimum | 0.2 | inch | |
| Clearance | Air gap (rotor to stator, Frame 8 removal), minimum | 5 | mm | |
| Clearance | Angular alignment T.I.R. limit | .001 per inch of radius | inch | |
| Clearance | Exhaust pipe to combustible wall or partition | 12 | inches (305 mm) | minimum |
| Clearance | Fan blade tips to fan shroud edge (Spec. A) | minimum 1/8 inch (3 mm) | inch | minimum |
| Clearance | Fan drive pulley alignment measurement (Spec. A) | 1.9 - 2.6 inch (48.3 - 66 mm) | inch | |
| Clearance | Fan drive pulley alignment offset (Spec. B) | 0.25 inch toward engine from straightedge | inch | |
| Clearance | Fan drive pulley position toward engine from straightedge | 0.25 | inch (nominal) | fan drive alignment |
| Clearance | Fuel lines to electrical wiring | 1/2 | inch (12.7 mm) | minimum |
| Clearance | Fuel lines to hot exhaust parts | 2 | inch (51 mm) | minimum |
| Clearance | Service/maintenance access clearance around genset | 1 | meter (3 feet) | generally, all sides |
| Clearance | Vibration isolator base elevation difference | 0.25 | inch (6 mm) | shimmed or grouted |
| Clearance | Vibration isolator base elevation difference | 0.25 inch (6 mm) | inch | maximum variation between isolator bases |
| Clearance | Vibration isolator top plate clearance | 0.25 inch (6 mm) or greater | inch | nominal or greater |
| Clearance | Vibration isolator top plate to base clearance | 0.25 | inch (6 mm) | minimum, on all isolators roughly equal |
| Other | Fan side bearing grease quantity | 39 | grams | |
| Other | Generator winding minimum insulation resistance (600 VAC or less), megger 500 VDC | 5.0 – 1.0 | megohms | main stator / main rotor |
| Other | Oil capacity, oil pan only, high capacity | 100 Gal (379 L) | Gal (L) | |
| Other | Oil capacity, oil pan only, standard capacity | 69 Gal (261 L) | Gal (L) | |
| Other | Oil capacity, system (w/Std. Filters), high capacity | 105 Gal (398 L) | Gal (L) | |
| Other | Oil capacity, system (w/Std. Filters), standard capacity | 74 Gal (280 L) | Gal (L) | |
| Other | Pulley side bearing grease quantity | 31 | grams | |
| Other | Start Delay adjustment range | 0 to 300 | seconds | remote starting in Auto mode |
| Other | Stop Delay adjustment range | 0 to 600 | seconds | remote stopping in Auto mode |
| Pressure | Maximum allowable exhaust back pressure | 6.8 | kPa (2.0 in [51 mm] H2O) | |
| Resistance | Battery corrected specific gravity, fully charged | 1.260 | corrected by adding 0.004 per 10q F above 80q F (27q C) | |
| Resistance | Battery specific gravity charge threshold | 1.215 | charge battery if reading below | |
| Resistance | Exciter rotor (Frame 7G) | 0.096 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter rotor (Frame 7H) | 0.096 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter rotor (Frame 8, HV814C) | 0.084 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter rotor (Frame 8, HV814D) | 0.084 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter rotor (Frame 8, HV814E) | 0.084 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter rotor (Frame 8, LV814C/LV814D) | 0.096 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter rotor (Frame 8, MV814C/MV814D) | 0.084 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter stator (Frame 7G) | 17 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter stator (Frame 7H) | 17 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter stator (Frame 8, HV814C) | 15 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter stator (Frame 8, HV814D) | 15 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter stator (Frame 8, HV814E) | 15 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter stator (Frame 8, LV814C/LV814D) | 15 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Exciter stator (Frame 8, MV814C/MV814D) | 15 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 7G) | 1.64 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 7H) | 1.75 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 8, HV814C) | 1.21 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 8, HV814D) | 1.28 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 8, HV814E) | 1.38 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 8, LV814C) | 1.33 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 8, LV814D) | 1.426 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 8, MV814C) | 1.164 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor (Frame 8, MV814D) | 1.229 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main rotor insulation minimum resistance, 5001 thru 15000 VAC | 1000 | Meg | |
| Resistance | Main rotor insulation minimum resistance, 600 VAC or less | 5.0 – 1.0 | Meg | new – in service |
| Resistance | Main stator (Frame 8, HV814C, 11K 50Hz) | 0.945 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main stator (Frame 8, HV814C, 7.2K 60Hz) | 0.340 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main stator (Frame 8, HV814D, 11K 50Hz) | 0.780 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main stator (Frame 8, HV814D, 7.2K 60Hz) | 0.280 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main stator (Frame 8, HV814E, 11K 50Hz) | 0.615 | ohms | approximately, at 68°F (20°C) +10% |
| Resistance | Main stator (Frame 8, HV814E, 7.2K 60Hz) | 0.220 | ohms | approximately, at 68°F (20°C) +10% |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | Refer to Cummins engine Operation and Maintenance Manual for coolant recommendations/specifications | Coolant level should be approximately in the middle of the sight glass with coolant temperature at 120q F (50q C) or lower. Do not add cold coolant to a hot engine; allow engine to cool to below 120q F (50q C). | |||
| Coolant | 50% ethylene or propylene glycol and 50% water | PGA drawing 0880-0152 | 100.0 Gal (379 L) | Spec. A jacket water (front) radiator capacity; Spec. A low-temperature aftercooling (rear) radiator 34 Gal (129 L). 2P2L (two pump two loop) cooling system. | |
| Engine oil | Refer to Cummins QSK45/60 Series Engine Operation and Maintenance Manual for lubricating oil recommendations/specifications | Oil capacity: oil pan only standard 69 Gal (261 L), high 100 Gal (379 L); system with std filters standard 74 Gal (280 L), high 105 Gal (398 L) | |||
| Fuel | ASTM No. 2 Diesel | Cummins engines normally use ASTM No. 2 Diesel fuel; will operate on alternate diesel fuels within QSK45/QSK60 specifications. Fuel filter/strainer/water separator of 100-120 mesh required. Never use galvanized or copper fuel lines. | |||
| Grease | Lithium based | Fan bearings: Mobilux EP 2, Mobilith AW 2, or Shell Alvania R3. Fan side bearing 39 grams; pulley side bearing 31 grams. | |||
| Grease | lithium based grease (Mobilux EP 2, Mobilith AW 2, or Shell Alvania R3) | Fan side bearing 39 grams, pulley side bearing 31 grams | |||
| Other | Fleetguard supplemental coolant additive (SCA), tradename DCA4 | 200.0 units (5 gallons [19 liters]) | Shipped with each radiator-cooled genset. If not filled using Fleetguard 'Compleat' antifreeze or equivalent, add 120 units (3 gallons [11.5 liters]) to jacket water (front) radiator and 80 units (2 gallons [7.5 liters]) to LTA (rear) radiator. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 111 | Internal ECM error | Shutdown | ||
| 112 | Actuator not responding | Shutdown | ||
| 113 | Actuator sensor fault | Warning | ||
| 115 | No speed signal | Shutdown | ||
| 116 | Time press sensor high | Shutdown | ||
| 117 | Time press sensor low | Shutdown | ||
| 118 | Pump press sensor high | Warning | ||
| 119 | Pump press sensor low | Warning | ||
| 121 | No engine speed signal | Warning | ||
| 122 | Manifold air press sensor | Warning | ||
| 123 | Manifold air press sensor | Warning | ||
| 135 | Oil pressure sensor | Warning | ||
| 141 | Oil pressure sensor | Warning | ||
| 143 | Low oil pressure | Warning | ||
| 144 | Coolant temperature sensor | Warning | ||
| 145 | Coolant temperature sensor | Warning | ||
| 146 | High coolant temp warning | Engine has begun to overheat and jacket water coolant temperature has risen to an unacceptable level | Warning | Reduce load by turning off non-critical loads; check air inlets/outlets for obstructions; if engine can be stopped follow code 151 procedure |
| 151 | High coolant temp alarm | Engine has overheated (coolant temperature above shutdown trip point) or coolant level is low | Shutdown | Allow engine to cool; check coolant level and leaks; check for airflow obstructions; check fan belt; reset control and restart |
| 152 | Low coolant temp | Engine coolant heater not operating or not circulating coolant; occurs when jacket water coolant temperature is 70°F (21°C) or lower | Warning | Check coolant heater power supply/fuse/cord; check for low coolant level and leaks |
| 153 | Manifold air temp sensor | Warning | ||
| 154 | Manifold air temp sensor | Warning | ||
| 155 | Manifold air temp alarm | Shutdown | ||
| 197 | Coolant level warning | Engine jacket water coolant level has fallen to an unacceptable level | Warning | If critical loads, wait until next shutdown then follow code 235 procedure |
| 212 | Oil temperature sensor | Warning | ||
| 213 | Oil temperature sensor | Warning | ||
| 214 | High oil temperature | Shutdown | ||
| 221 | Air pressure sensor | Warning | ||
| 222 | Air pressure sensor | Warning | ||
| 228 | Low coolant pressure | Shutdown | ||
| 231 | Coolant pressure sensor | Warning | ||
| 232 | Coolant pressure sensor | Warning | ||
| 233 | Coolant pressure warning | Shutdown | ||
| 234 | Overspeed | Shutdown | ||
| 235 | Coolant level alarm | Engine jacket water coolant level has fallen below the alarm trip point | Shutdown | Allow engine to cool; check coolant level and leaks; reset control and restart |
| 236 | Position sensor | Shutdown | ||
| 253 | Oil level alarm | Engine oil level has dropped below the shutdown trip point | Shutdown | Check oil level, lines and filters; replenish; reset control and restart |
| 254 | Fuel shutoff valve | Shutdown | ||
| 259 | Fuel shutoff valve | Warning | ||
| 261 | Fuel temperature sensor | Warning | ||
| 263 | Fuel temperature sensor | Warning | ||
| 265 | Fuel temperature sensor | Warning | ||
| 266 | Fuel temperature | Shutdown | ||
| 316 | Fuel supply pump | Warning | ||
| 318 | Fuel supply pump | Warning | ||
| 326 | Oil level warning | Engine oil level has exceeded warning trip point for high oil level | Warning | If critical loads, wait until next shutdown then follow code 688 procedure |
| 343 | Internal ECM error | Warning | ||
| 359 | Engine failed to start | Possible fault with control or starting system | Warning | Check battery cable connections; recharge or replace discharged/defective battery |
| 378 | Fueling actuator #1 | Warning | ||
| 379 | Fueling actuator #1 | Warning | ||
| 394 | Fueling actuator #1 | Warning | ||
| 395 | Fueling actuator #1 | Warning | ||
| 396 | Fueling actuator #2 | Warning | ||
| 397 | Fueling actuator #2 | Warning | ||
| 398 | Fueling actuator #2 | Warning | ||
| 399 | Fueling actuator #2 | Warning | ||
| 415 | Low oil pressure alarm | Shutdown | ||
| 421 | High oil temperature | Warning | ||
| 423 | Fuel timing | Warning | ||
| 441 | Low battery voltage | Battery voltage is below 24 VDC | Warning | Check battery charger fuse, recharge/replace battery; clean/tighten cable terminals; check engine DC alternator (normal charging voltage 24-26 VDC); check float level |
| 442 | High battery voltage | Battery voltage exceeds 32 VDC | Warning | Check float level on battery charger; check engine DC alternator |
| 449 | High fuel supply pressure | Warning | ||
| 451 | Fuel rail pressure sensor | Warning | ||
| 452 | Fuel rail pressure sensor | Warning | ||
| 455 | Fuel control valve sensor | Shutdown | ||
| 467 | Timing rail act sensor | Warning | ||
| 468 | Fuel rail actuator sensor | Warning | ||
| 471 | Low oil level | Engine oil has dropped to an unacceptable level | Warning | If critical loads, wait until next shutdown then follow code 253 procedure |
| 482 | High fuel supply pressure | Warning | ||
| 488 | High intake manifold temp | Warning | ||
| 498 | Oil level sensor | Warning | ||
| 499 | Oil level sensor | Warning | ||
| 514 | Fuel control valve | Shutdown | ||
| 546 | Fuel pressure sensor | Warning | ||
| 547 | Fuel pressure sensor | Warning | ||
| 554 | Fuel rail pressure sensor | Warning | ||
| 555 | Blowby pressure | Warning | ||
| 556 | Blowby pressure | Shutdown | ||
| 586 | Run/Stop switch | Shutdown | ||
| 587 | Run/Stop switch | Shutdown | ||
| 611 | Engine hot | An engine hot shutdown occurred (cool-down timers bypassed) because operator pressed Emergency Switch or moved 0/Manual/Auto switch to 0 while coolant temperature was above normal operating level | Warning | Avoid this type of shutdown; can cause loss of performance and engine damage |
Showing the first 80 of 191 codes.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
⚠ The fan belt idler is under tension; do not allow hands between idler and belt or fan hub.
Tools: Straightedge at least 48 inches (1219 mm), 8 mm hexagon wrench, 8-point socket and breaker bar or large wrench, Torque wrench
Tools: Straightedge at least 48 inches (1219 mm) long
⚠ The fan belt idler is under tension. Do not allow hands between the idler and the belt or the fan hub.
Tools: Straightedge at least 48 inches (1219 mm) long, 8-point socket and breaker bar
Tools: Dial indicator holding device, Magnetic base or clamp
Tools: Calibrated voltmeter
⚠ Disconnect negative battery cable(s) before beginning; accidental starting presents hazard of severe personal injury or death.
Tools: Dial indicator, Shims
Tools: Calibrated ammeter
⚠ Contacting high voltage components can cause electrocution; calibration must be performed by technically qualified personnel only.
Tools: Calibrated RMS multimeter (Fluke 87 or 8060A)
⚠ HIGH VOLTAGE. Touching uninsulated high voltage parts inside the control box can result in severe personal injury or death.
Tools: Jumper leads, 12 volt battery, Voltmeter
⚠ Hazardous voltage. After DC test voltage applied, reconnect Grounding Cluster to remove static charge after each test.
Tools: Megger
⚠ Layers of dust can cause diodes to overheat and fail. Brush dust off regularly.
Tools: Ohmmeter
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| Generator load terminals stamped U, V, W (line) and N (neutral); U, V, W correspond with L1, L2, L3 and N with L0 | Stranded load wires bolted to generator reconnection terminal block | Factory-connected to specified voltage; reconnection diagram located on upper side cover of control housing. Line-to-neutral voltage is the lower voltage shown and line-to-line is the higher rating. | ||
| 3 | Customer connections terminal blocks TB3, TB4 (Genset PCB), TB5 (Parallel/Extended I/O PCB), TB8 (Base PCB) | Digital connections: <1000 ft (305 m) use 20 gauge stranded copper; 1000-2000 ft (305-610 m) use 18 gauge stranded copper | B+ and Switched B+ fused at 20 amps. Use separate metal conduit from AC power cables. | |
| 12470 | 3-phase | Wye | Temp rise 105/80 C; duty S/P; ADS-521; feature code B567 | |
| 12470-13800 | 3-phase | Wye | Temp rise 125/105/80 C; duty S/P/C; ADS-521; feature code B488 | |
| 13200-13800 | 3-phase | Wye | Temp rise 105/80 C; duty S/P; ADS-521; feature code B612 | |
| 13800 | 3-phase | Wye | Temp rise 80 C; duty S; ADS-522; feature code B610 | |
| 380 | 3-phase | Wye | Temp rise 150/125/105 C; duty S/P/C; ADS-515; feature code B595 | |
| 4160 | 3-phase | Wye | Temp rise 125/105/80 C; duty S/P/C; ADS-518; feature code B467 | |
| 440 | 3-phase | Wye | Temp rise 125/105/80 C; duty S/P/C; ADS-334; feature code B663 | |
| 480 | 3-phase | Wye | Temp rise 125/105/80 C; duty S/P/C; ADS-334; feature code B462 | |
| 600 | 3-phase | Wye | Temp rise 125/105/80 C; duty S/P/C; ADS-334; feature code B465 |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Part # | Description | Category |
|---|---|---|
| 140-3288-02 | Cleaner, Air | Air filter |
| 140-3813 | Element, Air Cleaner Primary | Air filter |
| 140-3814 | Element, Safety (Air Cleaner) | Air filter |
| 140-3815 | Cleaner, Air (Dust Ejector) | Air filter |
| 140-3963 | Cleaner, Air (Spec A-C Metal) | Air filter |
| AF25593 | Element, Replacement (Spec A) (Fleetguard Part Number) | Air filter |
| AF25708M | Element, Replacement (Spec D-E) (Fleetguard Part Number) | Air filter |
| AF25750 | Element, Replacement (Spec B-C) (Fleetguard Part Number) | Air filter |
| 511-0161-17 | Belt, V Ribbed | Belt |
| M-3649982 | Juntade culata de cilindro - sobredimensionada 0,020" - M-3649982 | Cylinder head盖板 |
| QSK60 | Gas engine | Engine |
| QSK60-G9 | Engine model for C2500 D5A generator sets | Engine |
| QSK60G | Engine model QSK60G | Engine |
| 4321098765 | Fault Acknowledge Button | Fault acknowledge button |
| 130-4546 | Bracket, Mounting – Coolant Heater | Fluid |
| 130-4552 | Cover, Coolant Heater | Fluid |
| 338-3335-01 | Harness, Wiring – AC – Coolant Heater (From Coolant Heater Bottom To Coolant Heater Control Box) (Includes Conduit Connectors) (30”) | Fluid |
| 338-3335-09 | Harness, Wiring – AC – Coolant Heater (From Coolant Heater Bottom To Coolant Heater Control Box) (Includes Conduit Connectors) (108”) | Fluid |
| 338-3831 | Harness, Wiring – DC – Engine Heater (From Coolant Heater Control Box To Engine And Main Engine Harness) (Includes Parts Marked *) | Fluid |
| FS1006 | Filter, Fuel Water Separator | Fuel filter |
| 130-3684 | Gasket | Gasket |
| 130-5099 | Gasket | Gasket |
| 130-6405 | Gasket, Radiator | Gasket |
| 130-7145 | Gasket, Radiator | Gasket |
| 130-7232 | Gasket, Radiator (4") | Gasket |
| 130-7293 | Gasket, Radiator (65NB) | Gasket |
| 154-3182 | Gasket, Flange (Fuel Line) | Gasket |
| 155-3704 | Gasket, Exhaust (10" BS Flange) | Gasket |
| 155-4109 | Gasket, Flange | Gasket |
| 155-4601 | Gasket, Exhaust | Gasket |
| 155-4735 | Gasket, Exhaust (10" ANSI Flange) | Gasket |
| 186-6088 | Plate, Valve Spring | Gasket |
| 186-6090 | Carrier, Valve Spring | Gasket |
| 186-6091 | Cotter, Valve | Gasket |
| 186-6092 | Guide, Valve | Gasket |
| 186-6093 | Seal, Valve Stem | Gasket |
| 186-6109 | Gasket, Cylinder Head | Gasket |
| 186-6112 | Gasket, Cylinder Head | Gasket |
| 186-6436 | Gasket, Cylinder Head | Gasket |
| 186-6758 | Valve, Inlet | Gasket |
| 186-7004 | Insert, Inlet Valve | Gasket |
| 186-7005 | Insert, Exhaust Valve | Gasket |
| 186-7013 | Head Assy, Cylinder | Gasket |
| 186-7014 | Head Assy, Cylinder | Gasket |
| 186-7015 | Head Assy, Cylinder | Gasket |
| 319-3950 | Gasket, Operator Panel | Gasket |
| 319-3951 | Gasket, Switch Panel | Gasket |
| 330-0141-04 | Gasket, Cover | Gasket |
| MCBQSK0045 | Turbocharger Installation Kit | Gasket |
| MCBQSK0048 | Water Pump Gasket Set | Gasket |
| MCBQSK0058 | Water Pump Gasket Set | Gasket |
| 128-0108 | Insulation, Hose – Bulk (Order By The Foot – 12 Feet Required) | Hose |
| 130-4885 | Radiator (Includes Jacketwater, Aftercooler, Cap, Overflow Hose and Sight Gauge Sevice Parts) 130–3588 | Hose |
| 416-0680 | Cable, Battery (10") | Hose |
| 501-0838 | Line, Fuel (DN80 Gas 500mm) | Hose |
| 502-0656 | Adapter, Male (1–5/16–12 Tubing to 1” Pipe) | Hose |
| 502-0827 | Fitting, Hose – Barbed (1/2” ID Pipe to 3/4” ID Hose) | Hose |
| 502-0836 | Fitting, Brass – Hose – Barbed (3/4” Pipe to 3/4” Hose) | Hose |
| 502-1257 | Connector, Hose – Barbed (Fits 3/4” ID Hose) | Hose |
| 503-0189 | Clamp, Hose | Hose |
| 503-0249 | Hose − Bulk (Order by the Foot − 3 Feet Required) | Hose |
| 503-1136 | Clamp, Hose | Hose |
| 503-1418 | Hose − Bulk (1/4” ID) (Order By The Foot − 18 Feet Required) | Hose |
| 503-1634-01 | Hose, Rubber (3/4” ID x 4”) | Hose |
| 503-1726 | Hose (5” ID x 6”) | Hose |
| 503-1727 | Hose, Radiator (3” ID x 10”) | Hose |
| 503-1728 | Hose (3” ID x 5–1/2”) | Hose |
| 503-1745 | Hose – Bulk – Front Grease Fitting (Order By The Foot – 2 Feet Required) | Hose |
| 503-1863 | Hose, Radiator (1–1/2” ID x 4”) | Hose |
| 503-1872-01 | Clamp, Hose | Hose |
| 503-1872-05 | Clamp, Hose | Hose |
| 503-1872-09 | Clamp, Hose (5” ID) | Hose |
| 503-2204-06 | Hose, Steam (19mm x 300) | Hose |
| 503-2204-07 | Hose, Steam (19mm x 800) | Hose |
| 503-2204-08 | Hose, Steam (19mm x 1000) | Hose |
| 503-2204-09 | Hose, Steam (19mm x 1700) | Hose |
| 503-2518 | Hose, Vent | Hose |
| 505-1429 | Nipple, Pipe – Combination (1–1/2” Pipe to 1–1/2” Hose) | Hose |
| 505-2086 | Nipple, Pipe (3/4) | Hose |
| 505-2098 | Nipple, Pipe (1/2) | Hose |
| 518-0548-24 | Clamp, Hose | Hose |
| 518-0548-25 | Clamp, Hose (3/8” ID) | Hose |
| 0098-6074-02 | Label, Warning | Label |
| 098-2304 | Label, Warning | Label |
| 098-2304-01 | Label, Warning | Label |
| 098-4500 | Decal | Label |
| 098-4730 | Label, Warning | Label |
| 098-4732 | Label, Warning | Label |
| 098-4798 | Label, Warning | Label |
| 098-5347 | Label, Danger | Label |
| 098-5347-02 | Label, Danger | Label |
| 098-5759 | Label, Warning | Label |
| 098-5822 | Label, Warning | Label |
| 098-5842 | Label, Caution | Label |
| 098-6074-02 | Label, Warning | Label |
| 098-6195 | Label, Caution | Label |
| 098-6537 | Label, Ground | Label |
| 098-6650-01 | Label, Danger | Label |
| 098-6775 | Label | Label |
| 098-7614 | Label, Warning | Label |
| 098-7877 | Label, Battery Warning | Label |
| 098-7902-01 | Label, Logo | Label |
| 098-7902-03 | Label, Logo | Label |
| 098-7902-04 | Label, Logo | Label |
| 098-7904 | Label, Danger | Label |
| 098-8075 | Label, Ground | Label |
| 098-8144 | Label, Information | Label |
| 098-8204 | Label, Warning | Label |
| 098-8220 | Label, Information | Label |
| 098-8445 | Label, Information | Label |
| 098-8732-02 | Label, Information | Label |
| 098-8940 | Label, Warning | Label |
| A029M832 | Label, Warning | Label |
| A029S884 | Label, Information | Label |
| A029Z072 | Label, Information | Label |
| LF9050 | Lube, Combination | Oil filter |
| 0130-5997-05 | Cummins Part No. 312/212, 37564; Cummins Part No. 312/212, 37604; Cummins Part No. 212, 37558; Cummins Part No. 212, 37614; Cummins Part No. 212, 37627; Cummins Part No. 313/312, 0179-2921; Cummins Part No. 313/312, 0179-2988; Cummins Part No. 312, 0179-3291; Cummins Part No. 312/212, 130-5791; Cummins Part No. 312/212, 37644; Cummins Part No. 312/212, 37624; Cummins Part No. 312/212, 37625; Cummins Part No. 212, 37648; Cummins Part No. 212, 37643; Cummins Part No. 212, 37678; Cummins Part No. 212, 37665; Cummins Part No. 312/212, 37676; Cummins Part No. 312/212, 37610; Cummins Part No. 313/212, 37642 | Service part / kit |
| 0179-2862 | Nema 284T frame has the following arrangement: 6311 C3 / 18gram Polyrex – EM /20,000h | Service part / kit |
| 0179-3291 | Nema 284T frame has the following arrangement: 6311 C3 / 11gram Polyrex – EM /20,000h | Service part / kit |
| 098-5387 | Label, Danger | Service part / kit |
| 130-5077-02 | Tube, Heater | Service part / kit |
| 130-5078-02 | Tube, Heater | Service part / kit |
| 130-5079-02 | Tube, Heater | Service part / kit |
| 130-5080-02 | Tube, Heater | Service part / kit |
| 130-5089-02 | Tube, Heater | Service part / kit |
| 155-4734 | Flange, Exhaust (10" ANSI Flange) | Service part / kit |
| 155-4736 | Flange, Exhaust (10" BS Flange) | Service part / kit |
| 186-6087 | Valve, Exhaust | Service part / kit |
| 186-6089 | Part 186-6089 | Service part / kit |
| 3163156 | Service cable for InPower™ | Service part / kit |
| 323-1491 | * Pin, Contact (Used With Inline G) | Service part / kit |
| 323-1492 | * Socket, Contact (Used In Stations 18, 19) | Service part / kit |
| 323-1688 | * Socket, Contact (Used In P1) | Service part / kit |
| 323-1718 | * Pin, Contact (Used In Station 17) | Service part / kit |
| 333-0634-02 | Heater, Coolant - 6420 Watt | Service part / kit |
| 3886301 | InPower™ electronic service tool | Service part / kit |
| 4-2002 | PowerCommand Control | Service part / kit |
| 416-1019 | Boot, Battery (Red) | Service part / kit |
| 504-0215 | Valve, Check (1/4) | Service part / kit |
| 504-0239 | Valve, Ball (3/4) | Service part / kit |
| 504-0247 | Valve, Ball (1/2) | Service part / kit |
| 504-0294 | Valve, Ball (3 Way 2" DN80) - ANSI Flanges | Service part / kit |
| 504-0295 | Valve, Ball (3 Way 3" DN80) - ANSI Flanges | Service part / kit |
| 504-0301 | Valve, Ball (3 Way 2" DN80) - BS Flanges | Service part / kit |
| 504-0302 | Valve, Ball (3 Way 3" DN80) - BS Flanges | Service part / kit |
| 525-0304 | Gallon Can | Service part / kit |
| 525-0305 | 12 oz. Pressurized Spray Can | Service part / kit |
| 525-0306 | Quart Can | Service part / kit |
| 5410770 | Cummins enclosed C2000D5 diesel generator set powered by QSK60G3 engine provides reliable continuous power for Bab Gas Compression Facility. | Service part / kit |
| 898-1254-25 | Sleeving – Heater Leads (59”) | Service part / kit |
| A026N045 | Bracket, Mounting | Service part / kit |
| A026N055 | Bracket, Mounting | Service part / kit |
| A026N058 | Leg, Box | Service part / kit |
| A026N061 | Leg, Box | Service part / kit |
| A026N070 | Panel, Cover | Service part / kit |
| A029F250 | Insulation, Duct | Service part / kit |
| A029F255 | Insulation, Duct | Service part / kit |
| A029S366 | Lead, Ground | Service part / kit |
| A029Y658 | Stud | Service part / kit |
| A040C685 | Bracket, Support | Service part / kit |
| A041U339 | Shim, Generator Mounting | Service part / kit |
| A041U341 | Shim, Generator Mounting | Service part / kit |
| A056A610 | RECOMMENDED SPARES LIST (RSL) FOR DQKAD GENERATOR SETS | Service part / kit |
| A056A611 | RECOMMENDED SPARES LIST (RSL) FOR DQKAE GENERATOR SETS | Service part / kit |
| A056A612 | RECOMMENDED SPARES LIST (RSL) FOR DQKAF GENERATOR SETS | Service part / kit |
| A056F840 | Recommended Spares List (RSL) for DQKAN Generator Sets | Service part / kit |
| M-3089173 | Bushing - Camshaft | Service part / kit |
| M-4007741 | Bushing - Camshaft | Service part / kit |
| M-4089083 | Single Cylinder Head | Service part / kit |
| M-4089200 | Juego de Junta Modul. N. ° de Pieza | Service part / kit |
| M-4089201 | Juego Posenfriador Cuadrante N. ° de Pieza | Service part / kit |
| M-4089202 | Juego Sistema Enfriamiento N. ° de Pieza | Service part / kit |
| M-4089231 | Juego de Junta Modul. N. ° de Pieza | Service part / kit |
| M-4089232 | Juego Posenfriador Cuadrante N. ° de Pieza | Service part / kit |
| M-4089307 | Juego Bomba Inferior N. ° de Pieza | Service part / kit |
| M-4089308 | Juego Combustible Inferior N. ° de Pieza | Service part / kit |
| M-4089508 | Juego de Junta Modul. N. ° de Pieza | Service part / kit |
| M-4089509 | Juego Sistema Enfriamiento N. ° de Pieza | Service part / kit |
| M-4089874 | Juego Bloque Inferior N. ° de Pieza | Service part / kit |
| M-4955369 | Juego Posenfriador Cuadrante N. ° de Pieza | Service part / kit |
| M-4955370 | Juego de Junta Modul. N. ° de Pieza | Service part / kit |
| M-4956000 | Culata Cilindro Simple N. ° de Pieza AR | Service part / kit |
| 132-0475 | Pump, Water (Remote) | Pump |
| A054B161 | Schematic Diagram | Schematic diagram |
| 323-1445 | * Seal, Cable (Used With Station 17) | Seal |
| 323-1708 | # Seal, Cable (P8) | Seal |
| 503-2129-05 | Line, Vent – Flexible – With One Male Pipe Swivel and One Female Pipe Swivel With O–Ring Face Seal (1/4” ID x 94–1/2”) Right Side | Seal |
| 509-0283-01 | Seal | Seal |
| 509-0478 | Seal - O Ring | Seal |
| 193-0486 | Sender, Low Coolant Level | Sensor |
| 338-3832 | Harness, Wiring – Low Coolant Level Sender (4 Wire, 169”) (Includes Parts Marked *) | Sensor |
| 504-0262 | Valve, Solenoid | Sensor |
| AM47478880 | Temperature Sender, Exhaust Temperature Replaces 47367178, 87482353, LB52S00001P1 | Sensor |
| AM47520140 | Sensor, 8-Pin/NH3/Ammonia Replaces 47368956, 84382712 | Sensor |
| AM47520143 | Sensor, Def/AdBlue Quality Replaces 84553250 | Sensor |
| AM504372225 | Sensor, MAP Temperature/Pressure Replaces 2852821, 4896794, 504073323 | Sensor |
| M-3331970 | Spacer Gasket for QSK45 and QSK60 Engine applications | Spacer gasket |
| 309-0649 | Thermostat (Includes Connector Socket) (S11) | Thermostat |
| 309-0711 | Thermostat | Thermostat |
| M-4089203 | Juego Turbo e Interenfriador N. ° de Pieza | Turbocharger |
| M-4089233 | Juego Turbo e Interenfriador N. ° de Pieza | Turbocharger |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
The Cummins/Onan QSK60-G6 (2P/2L) powers 1 generator set(s), including Cummins/Onan DQKC.
A commonly reported issue on generators using the Cummins/Onan QSK60-G6 (2P/2L) is: LOW BATTERY VOLTAGE — Indicates battery voltage is below 24 VDC.. Cause: Discharged or defective battery. Fix: Check the battery charger fuse. Recharge or replace the battery..