15
  • Time press sensor low 117
  • Time press sensor high 116
  • The warning status indicator is lit whenever the control detects a warning condition.
    Fix: After the condition is corrected, the warning indicator can be reset by pressing the Fault Acknowledge button. (It is not necessary to stop the generator set if the fault becomes inactive during genset operation.)
  • The shutdown status indicator is lit whenever the control detects a shutdown condition.
    Fix: After the condition is corrected, the shutdown indicator can be reset by turning the O/Manual/Auto switch to the O (off) position, and pressing the Fault Acknowledge button. The generator set can not be started when this lamp is on.
  • The genset control continuously monitors engine sensors for abnormal conditions, such as low oil pressure and high coolant temperature.
    Fix: If any of these conditions occur, the control will light a yellow Warning lamp or a red Shutdown lamp and display a message on the graphical display panel.
  • Pump press sensor low 119
  • Pump press sensor high 118
  • POWER DOWN ERROR 1417
    Fix: Possible drain on battery. Contact an authorized service center for service.
  • Oil pressure sensor 135
  • OIL LEVEL WARNING 326
    Fix: If generator is powering critical loads and cannot be shut down, wait until next shutdown period, then follow 688 High Oil Level Alarm procedure. If engine can be stopped follow 688 procedure.
  • OIL LEVEL ALARM 253
    Fix: Check oil level, lines and filters. If oil system is OK but oil level is low, replenish. Reset control and restart.
  • No speed signal 115
  • No engine speed signal 121
  • Manifold air temp sensor 153
  • Manifold air press sensor 122

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan QSK60-G6 (2P/2L).

Service intervals

22
ItemActionHoursMonthsNotes
Coolant heater(s)Check8 hrDaily
Coolant level of radiatorsCheck8 hrDaily
Engine oil levelCheck8 hrDaily
General set inspectionInspect8 hrDaily; check for oil, fuel, cooling and exhaust system leaks
All hardware (fittings, clamps, fasteners)Check100 hr
Battery charging systemCheck100 hr
Battery electrolyte levelCheck100 hr
Drive beltsCheck100 hrVisually check for wear or slippage; replace if hard or brittle
Exhaust condensate trapDrain100 hr
Generator air outletCheck100 hr
Fan bearings (two)Lubricate250 hr6 mo
Radiator hosesInspect250 hr6 moCheck for wear and cracks
Generator bearing (Frame 7 / Frame 8)Lubricate500 hr
Generator insulation resistanceTest500 hr
Air cleanerCheck1000 hrReplace as necessary
Anti-freeze and DCA concentrationCheck1000 hr
Crankcase breatherClean1000 hr
Engine oil and filterChange1000 hr
Fuel filter(s)Drain1000 hr
Jacket Water & LTA cooling systemsClean1000 hr
Jacket water coolant filtersChange1000 hr
Fuel filtersChange4000 hr

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAir gap (rotor to stator), normal0.3inch
ClearanceAir gap (rotor to stator), normal7.5mm
ClearanceAir gap (rotor to stator, Frame 8 removal), minimum0.2inch
ClearanceAir gap (rotor to stator, Frame 8 removal), minimum5mm
ClearanceAngular alignment T.I.R. limit.001 per inch of radiusinch
ClearanceExhaust pipe to combustible wall or partition12inches (305 mm)minimum
ClearanceFan blade tips to fan shroud edge (Spec. A)minimum 1/8 inch (3 mm)inchminimum
ClearanceFan drive pulley alignment measurement (Spec. A)1.9 - 2.6 inch (48.3 - 66 mm)inch
ClearanceFan drive pulley alignment offset (Spec. B)0.25 inch toward engine from straightedgeinch
ClearanceFan drive pulley position toward engine from straightedge0.25inch (nominal)fan drive alignment
ClearanceFuel lines to electrical wiring1/2inch (12.7 mm)minimum
ClearanceFuel lines to hot exhaust parts2inch (51 mm)minimum
ClearanceService/maintenance access clearance around genset1meter (3 feet)generally, all sides
ClearanceVibration isolator base elevation difference0.25inch (6 mm)shimmed or grouted
ClearanceVibration isolator base elevation difference0.25 inch (6 mm)inchmaximum variation between isolator bases
ClearanceVibration isolator top plate clearance0.25 inch (6 mm) or greaterinchnominal or greater
ClearanceVibration isolator top plate to base clearance0.25inch (6 mm)minimum, on all isolators roughly equal
OtherFan side bearing grease quantity39grams
OtherGenerator winding minimum insulation resistance (600 VAC or less), megger 500 VDC5.0 – 1.0megohmsmain stator / main rotor
OtherOil capacity, oil pan only, high capacity100 Gal (379 L)Gal (L)
OtherOil capacity, oil pan only, standard capacity69 Gal (261 L)Gal (L)
OtherOil capacity, system (w/Std. Filters), high capacity105 Gal (398 L)Gal (L)
OtherOil capacity, system (w/Std. Filters), standard capacity74 Gal (280 L)Gal (L)
OtherPulley side bearing grease quantity31grams
OtherStart Delay adjustment range0 to 300secondsremote starting in Auto mode
OtherStop Delay adjustment range0 to 600secondsremote stopping in Auto mode
PressureMaximum allowable exhaust back pressure6.8kPa (2.0 in [51 mm] H2O)
ResistanceExciter rotor (Frame 7G)0.096ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter rotor (Frame 7H)0.096ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter rotor (Frame 8, HV814C)0.084ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter rotor (Frame 8, HV814D)0.084ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter rotor (Frame 8, HV814E)0.084ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter rotor (Frame 8, LV814C/LV814D)0.096ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter rotor (Frame 8, MV814C/MV814D)0.084ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter stator (Frame 7G)17ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter stator (Frame 7H)17ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter stator (Frame 8, HV814C)15ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter stator (Frame 8, HV814D)15ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter stator (Frame 8, HV814E)15ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter stator (Frame 8, LV814C/LV814D)15ohmsapproximately, at 68°F (20°C) +10%
ResistanceExciter stator (Frame 8, MV814C/MV814D)15ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 7G)1.64ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 7H)1.75ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 8, HV814C)1.21ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 8, HV814D)1.28ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 8, HV814E)1.38ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 8, LV814C)1.33ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 8, LV814D)1.426ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 8, MV814C)1.164ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor (Frame 8, MV814D)1.229ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain rotor insulation minimum resistance, 5001 thru 15000 VAC1000Meg
ResistanceMain rotor insulation minimum resistance, 600 VAC or less5.0 – 1.0Megnew – in service
ResistanceMain stator (Frame 8, HV814C, 11K 50Hz)0.945ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain stator (Frame 8, HV814C, 7.2K 60Hz)0.340ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain stator (Frame 8, HV814D, 11K 50Hz)0.780ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain stator (Frame 8, HV814D, 7.2K 60Hz)0.280ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain stator (Frame 8, HV814E, 11K 50Hz)0.615ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain stator (Frame 8, HV814E, 7.2K 60Hz)0.220ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain stator (Frame 8, LV814C, 440-480V 60Hz)0.000483ohmsapproximately, at 68°F (20°C) +10%
ResistanceMain stator (Frame 8, LV814D, 440-480V 60Hz)0.000368ohmsapproximately, at 68°F (20°C) +10%

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50% ethylene or propylene glycol and 50% waterPGA drawing 0880-0152100.0 Gal (379 L)Spec. A jacket water (front) radiator capacity; Spec. A low-temperature aftercooling (rear) radiator 34 Gal (129 L). 2P2L (two pump two loop) cooling system.
Engine oilRefer to Cummins QSK45/60 Series Engine Operation and Maintenance Manual for lubricating oil recommendations/specificationsOil capacity: oil pan only standard 69 Gal (261 L), high 100 Gal (379 L); system with std filters standard 74 Gal (280 L), high 105 Gal (398 L)
FuelASTM No. 2 DieselCummins engines normally use ASTM No. 2 Diesel fuel; will operate on alternate diesel fuels within QSK45/QSK60 specifications. Fuel filter/strainer/water separator of 100-120 mesh required. Never use galvanized or copper fuel lines.
Greaselithium based grease (Mobilux EP 2, Mobilith AW 2, or Shell Alvania R3)Fan side bearing 39 grams, pulley side bearing 31 grams
OtherFleetguard supplemental coolant additive (SCA), tradename DCA4200.0 units (5 gallons [19 liters])Shipped with each radiator-cooled genset. If not filled using Fleetguard 'Compleat' antifreeze or equivalent, add 120 units (3 gallons [11.5 liters]) to jacket water (front) radiator and 80 units (2 gallons [7.5 liters]) to LTA (rear) radiator.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

80
CodeNameMeaningSeverityAction
111Internal ECM errorShutdown
112Actuator not respondingShutdown
113Actuator sensor faultWarning
115No speed signalShutdown
116Time press sensor highShutdown
117Time press sensor lowShutdown
118Pump press sensor highWarning
119Pump press sensor lowWarning
121No engine speed signalWarning
122Manifold air press sensorWarning
123Manifold air press sensorWarning
1311Customer input #1Customer defined fault; nature is an optional customer selection
1312Customer input #2Customer defined fault
1313Network Fault 1
1314Network Fault 2
1315Network Fault 3
1316Network Fault 4
1317Customer input #3
1318Customer input #4
1319High alternator tempWarning
1321Common warning driverWarning
1322Load gov kW setpoint oor hiShutdown
1323Load gov kW setpoint oor loShutdown
1324Load gov kVAR oor hiWarning
1325Load gov kVAR oor loWarning
1326Backup starter disconnectWarning
1327Load gov kW analog oorShutdown
1328Genset CB trippedWarning
1329AVR DC power failureWarning
1331AVR driver shortedShutdown
1332Manual switch oor loShutdown
1333Manual switch oor hiShutdown
1334Critical scaler oorShutdown
1335Non critical scaler oorWarning
1336Cooldown completeShutdown
1337Network winkInfo
1341Load demand stopShutdown
1342Slot 0 cardShutdown
1343Slot 1 cardShutdown
1344Slot 2 cardShutdown
1345Slot 3 cardShutdown
1346Slot 4 incorrectShutdown
1347Slot 5 cardShutdown
1348Slot 6 cardShutdown
1349Slot 7 cardShutdown
135Oil pressure sensorWarning
1351Slot 4 / network enabledWarning
141Oil pressure sensorWarning
1414Run relay contactWarning
1415Run relay driverWarning
1416Fail to shutdownFault Bypass mode is enabled; used by service personnel for troubleshooting; ignores majority of system shutdown faultsWarning
1417Power down errorControl cannot power down due to unknown condition; possible drain on batteryWarningContact an authorized service center for service
1419Fuel rail driverWarning
1421Timing rail driver #1Warning
1422Timing rail driver #2Warning
1424High side driverWarning
1427Overspeed relay driverWarning
1428LOP shutdown relay driverWarning
143Low oil pressureWarning
1433Emergency stop – localLocal Emergency StopShutdownPull button out, move O/Manual/Auto switch to O, press Fault Acknowledge, select Manual or Auto
1434Emergency stop – remoteRemote Emergency StopShutdownPull button out, move O/Manual/Auto switch to O, press Fault Acknowledge, select Manual or Auto
1435Engine coldWarning
1436PT fuel system driversWarning
1437E-stop path fuse blownShutdown
1438Fail to crankPossible fault with control or starting systemWarningCheck battery cable connections; recharge or replace discharged/defective battery
1439Fuel level low in dayFuel supply is running lowWarningCheck fuel supply and replenish
144Coolant temperature sensorWarning
1441Fuel level low in mainFuel supply is running lowWarningCheck fuel supply and replenish
1442Battery is weakBattery voltage drops below 14.4 volts for two seconds during startingWarningSee warning message 441 Low Battery Voltage
1443Battery is deadBattery has dropped below genset operating range (3.5 volts when cranking) to power starter and control circuitryWarningSee warning message 441 Low Battery Voltage
1444kW overloadWarning
1445Alternator short circuitShutdown
1446AC output voltage is highShutdown
1447AC output voltage is lowShutdown
1448AC output frequency lowShutdown
1449AC output frequency highWarning
145Coolant temperature sensorWarning
1451Gen/Bus voltage differWarning
1452Gen CB failed to closeShutdown
1453Gen CB failed to openShutdown

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Align Cooling System Fan Drive adjustment

⚠ The fan belt idler is under tension; do not allow hands between idler and belt or fan hub.

Tools: Straightedge at least 48 inches (1219 mm), 8 mm hexagon wrench, 8-point socket and breaker bar or large wrench, Torque wrench

  1. Use a long straightedge to align crankshaft pulley to fan drive pulley; fan pulley 0.25 inch toward engine.
  2. Mark current and estimated new fan drive pulley location on shaft.
  3. Remove two screws from fan pulley bushing; install one screw in threaded hole to separate bushing.
  4. Move bushing to the new location mark.
  5. Install the two screws into the bushing and tighten alternately to 67 ft-lbs (91 N•m) torque.
  6. Recheck alignment and repeat procedure until alignment is achieved.
  7. Install the drive belt using an 8-point socket and breaker bar to hold idler against spring tension.
Align Cooling System Fan Drive (Spec. A) adjustment

Tools: Straightedge at least 48 inches (1219 mm) long

  1. Use a long straightedge to align the crankshaft pulley to the fan drive pulley.
  2. Check for no visible gaps between straightedge and pulley surfaces.
  3. Mark current and estimated new fan drive pulley location on shaft.
  4. Remove three fan pulley bushing screws; install two into threaded holes to separate bushing.
  5. Move bushing to the new location mark.
  6. Install the 3 screws through bushing into pulley and tighten sequentially to 29 ft-lbs (39 N·m).
  7. Recheck alignment and repeat procedure until achieved.
  8. Loosen pillow block bearing mounting bolts; add shims between bearing housing and pedestal.
  9. Tighten bearing mounting bolts to 85 ft-lbs (116 N·m), then lockcollars to 38 ft-lbs (52 N·m).
  10. Rotate fan by hand; ensure minimum 1/8 inch (3 mm) fan blade tip to shroud clearance.
  11. Adjust fan shroud using slotted holes if clearance is insufficient.
Align Cooling System Fan Drive (Spec. B) adjustment

⚠ The fan belt idler is under tension. Do not allow hands between the idler and the belt or the fan hub.

Tools: Straightedge at least 48 inches (1219 mm) long, 8-point socket and breaker bar

  1. Use a long straightedge to align the crankshaft pulley to the fan drive pulley.
  2. Fan drive pulley should be 0.25 inch nominal toward engine from straightedge.
  3. Mark current and estimated new fan pulley location on shaft.
  4. Remove two fan pulley bushing screws; install one into threaded hole to separate bushing.
  5. Move bushing to the new location mark.
  6. Install the two screws into the bushing and tighten alternately to 67 ft-lbs (91 N·m).
  7. Recheck alignment and repeat until achieved.
  8. Install drive belt using 8-point socket and breaker bar to relieve idler spring tension.
Axial Alignment Procedure adjustment

Tools: Dial indicator holding device, Magnetic base or clamp

  1. Perform only when an objectionable vibration is present.
  2. Fasten dial indicator holding device to skid base, engine block, or generator shell so the sensor rests on the generator shaft hub.
  3. Bar the engine over clockwise through a couple of rotations and record readings in eight equally spaced points around the shaft diameter.
  4. To correct out-of-tolerance T.I.R., remove the capscrews connecting drive discs and flywheel; mark drive discs and flywheel.
  5. Rotate engine or generator so drive disc holes are repositioned 180 degrees from original location; retorque capscrews.
  6. Re-check shaft alignment; if unchanged, rotate discs 30, 60, or 90 degrees from original location.
  7. If T.I.R. still does not improve, inspect flywheel pilot and drive disc runouts.
Bus Voltage Calibration (C) adjustment

Tools: Calibrated voltmeter

  1. Display the Bus Voltage Calibration submenu.
  2. With all gensets OFF, attach a calibrated voltmeter to TB1-A (L1) and TB1-B (L2) of the bus PT module.
  3. Start another genset, allow it to reach normal speed and voltage, and connect operating genset to the bus.
  4. Calibrate the Bus Volts L1 reading so the display matches the calibrated meter.
  5. Shut the generator set OFF.
  6. Repeat steps 2 through 5 for Bus Volts L2 and L3.
  7. Exit menu to save changes.
Frame 7 Angular Alignment Procedure adjustment

⚠ Disconnect negative battery cable(s) before beginning; accidental starting presents hazard of severe personal injury or death.

Tools: Dial indicator, Shims

  1. Disconnect the negative (–) battery cable(s) before beginning.
  2. Fasten a dial indicator to the generator shaft or cooling fan with the sensing point on the capscrew head or flat of the drive disc at bolt circle diameter.
  3. Bar the engine over clockwise (viewed from engine flywheel); do not allow it to roll back on compression.
  4. Record T.I.R. as the sum of the maximum positive and negative readings over one revolution.
  5. To correct, remove or add equal shims under the four generator mounting feet.
  6. Approximate shim change: multiply (step 1 to step 2 distance ratio) by one half the T.I.R.
Genset Ammeter Display Calibration (B) adjustment

Tools: Calibrated ammeter

  1. Display the Current Calibration submenu.
  2. With the genset OFF, attach a calibrated ammeter to L1.
  3. Start the genset and allow it to reach normal operating speed.
  4. Load the genset to maximum rated kVA at rated voltage.
  5. Calibrate the L1 current reading so the display agrees with the calibrated ammeter.
  6. Repeat steps 2 through 5 for L2 and L3.
  7. Exit menu to save changes.
Genset Voltage Display Calibration (A) adjustment

⚠ Contacting high voltage components can cause electrocution; calibration must be performed by technically qualified personnel only.

Tools: Calibrated RMS multimeter (Fluke 87 or 8060A)

  1. Display the Voltage Calibration submenu.
  2. With the genset OFF, attach a calibrated voltmeter to the AC output from L1 to L2.
  3. Start the genset and allow it to reach normal operating speed.
  4. Calibrate voltage reading for L1 so the display agrees with the calibrated voltmeter.
  5. Shut the generator set OFF.
  6. Repeat steps 2 through 5 for L2 and L3.
  7. Exit menu to save changes.
Generator/PCC Control Isolation Procedure diagnostic

⚠ HIGH VOLTAGE. Touching uninsulated high voltage parts inside the control box can result in severe personal injury or death.

Tools: Jumper leads, 12 volt battery, Voltmeter

  1. Throw line circuit breaker OFF and shut down the set.
  2. Remove electronics box cover; remove connector 10 from regulator output module.
  3. Prepare to measure output voltage across generator terminals while set is running.
  4. Bring jumpers from a 12 volt battery to X (Field +, red wire 10-6) and XX (Field –, brown wire 10-3) pins of plug P10.
  5. Check polarity again; polarity must be correct or test is inconclusive.
  6. Start the set and connect the jumper from battery negative terminal to the XX lead.
  7. If rated voltage or higher and phases balanced, generator circuitry is probably okay; otherwise troubleshoot.
  8. If voltages unbalanced, troubleshoot main stator first; if uniformly low, troubleshoot exciter and field circuits first.
Megger and PI Test diagnostic

⚠ Hazardous voltage. After DC test voltage applied, reconnect Grounding Cluster to remove static charge after each test.

Tools: Megger

  1. Perform the Generator Set Grounding Procedure.
  2. Disconnect connector 10 from voltage regulator output stage and AC control leads 5,6,7,8.
  3. If RTD option installed, ground all six RTD temperature leads (18 leads total).
  4. Main Stator: remove and separate neutral leads from terminal 'N'.
  5. Connect megger between one stator phase and ground, grounding other two phases; test.
  6. Repeat stator test for the other two phases.
  7. Main Rotor: disconnect rotor and voltage suppressor leads from F1+ and F2-.
  8. Connect megger between one rotor lead and ground and conduct the test.
Testing Diodes (Rotating Rectifier Assembly) diagnostic

⚠ Layers of dust can cause diodes to overheat and fail. Brush dust off regularly.

Tools: Ohmmeter

  1. Disconnect the diode pigtails from the terminal posts.
  2. Using an ohmmeter, measure resistance between each diode pigtail and the plate on which it is mounted.
  3. Reverse meter test probes and repeat; resistance should be high in one direction and low in the other.
  4. If resistance is high or low in both directions, replace the diode.
Testing the Exciter Rotor diagnostic

Tools: Wheatstone bridge, Megger

  1. Disconnect the six rotor winding leads from the terminal posts on the rectifier assembly.
  2. With a Wheatstone bridge, measure resistance across each pair of windings: U-V, V-W, W-U.
  3. Replace the whole rotor shaft assembly if resistance of any winding is not as specified in Tables 4-2/4-3.
  4. Disconnect all six exciter rotor leads from diode terminals CR1 through CR6 and isolate from ground.
  5. Connect the megger between one lead and ground and conduct the test per Table 4-1.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
Generator load terminals stamped U, V, W (line) and N (neutral); U, V, W correspond with L1, L2, L3 and N with L0Stranded load wires bolted to generator reconnection terminal blockFactory-connected to specified voltage; reconnection diagram located on upper side cover of control housing. Line-to-neutral voltage is the lower voltage shown and line-to-line is the higher rating.
3Customer connections terminal blocks TB3, TB4 (Genset PCB), TB5 (Parallel/Extended I/O PCB), TB8 (Base PCB)Digital connections: <1000 ft (305 m) use 20 gauge stranded copper; 1000-2000 ft (305-610 m) use 18 gauge stranded copperB+ and Switched B+ fused at 20 amps. Use separate metal conduit from AC power cables.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Cummins/Onan QSK60 family

151
Part #DescriptionCategory
140-3288-02Cleaner, Airair_filter
140-3963Filter, Airair_filter
AF25593Element, Replacement (Spec A) (Fleetguard Part Number)air_filter
AF25708MElement, Replacement (Spec D-E) (Fleetguard Part Number)air_filter
AF25750Element, Replacement (Spec B-C) (Fleetguard Part Number)air_filter
511-0161-17Belt, V Ribbedbelt
M-3649982Juntade culata de cilindro - sobredimensionada 0,020" - M-3649982cylinder_head盖板
QSK60Gas engineengine
QSK60-G9Engine model for C2500 D5A generator setsengine
4321098765Fault Acknowledge Buttonfault_acknowledge_button
130-4546Bracket, Mounting – Coolant Heaterfluid
130-4552Cover, Coolant Heaterfluid
338-3335-01Harness, Wiring – AC – Coolant Heater (From Coolant Heater Bottom To Coolant Heater Control Box) (Includes Conduit Connectors) (30”)fluid
338-3335-09Harness, Wiring – AC – Coolant Heater (From Coolant Heater Bottom To Coolant Heater Control Box) (Includes Conduit Connectors) (108”)fluid
338-3831Harness, Wiring – DC – Engine Heater (From Coolant Heater Control Box To Engine And Main Engine Harness) (Includes Parts Marked *)fluid
FS1006Filter, Fuel Water Separatorfuel_filter
130-3684Gasketgasket
130-5099Gasketgasket
319-3950Gasket, Operator Panelgasket
319-3951Gasket, Switch Panelgasket
330-0141-04Gasket, Covergasket
MCBQSK0045Turbocharger Installation Kitgasket
MCBQSK0048Water Pump Gasket Setgasket
MCBQSK0058Water Pump Gasket Setgasket
1750DQKBGENSET MODEL AND WATTAGE (kW/MW)genset_model_and_wattage
128-0108Insulation, Hose - Bulk (7/8º ID) (Order By The Foot - 10 Feet Required)hose
130-4885Radiator (Includes Jacketwater, Aftercooler, Cap, Overflow Hose and Sight Gauge Sevice Parts) 130–3588hose
416-0680Cable, Battery (10")hose
502-0656Adapter, Male (1–5/16–12 Tubing to 1” Pipe)hose
502-0827Hose, Barb (1/2–14)hose
502-0836Fitting, Brass – Hose – Barbed (3/4” Pipe to 3/4” Hose)hose
502-1257Connector, Hose – Barbed (Fits 3/4” ID Hose)hose
503-0189Clamp, Hosehose
503-0249Hose − Bulk (Order by the Foot − 3 Feet Required)hose
503-1136Clamp, Hosehose
503-1418Hose − Bulk (1/4” ID) (Order By The Foot − 18 Feet Required)hose
503-1634-01Hose, Rubber (3/4” ID x 4”)hose
503-1726Hose (5” ID x 6”)hose
503-1727Hose, Radiator (3” ID x 10”)hose
503-1728Hose (3” ID x 5–1/2”)hose
503-1745Hose – Bulk – Front Grease Fitting (Order By The Foot – 2 Feet Required)hose
503-1863Hose, Radiator (1–1/2” ID x 4”)hose
503-1872-05Clamp, Hosehose
503-1872-09Clamp, Hose (5” ID)hose
505-1429Nipple, Pipe – Combination (1–1/2” Pipe to 1–1/2” Hose)hose
518-0548-25Clamp, Hose (3/8” ID)hose
0098-6074-02Label, Warninglabel
098-2304Label, Warninglabel
098-2304-01Label, Warninglabel
098-4500Decallabel
098-4730Label, Warninglabel
098-4732Label, Warninglabel
098-4798Label, Warninglabel
098-5347Label, Dangerlabel
098-5347-02Label, Dangerlabel
098-5387Label, Dangerlabel
098-5759Label, Warninglabel
098-5822Label, Warninglabel
098-5842Label, Cautionlabel
098-6074-02Label, Warninglabel
098-6195Label, Cautionlabel
098-6537Label, Groundlabel
098-6650-01Label, Dangerlabel
098-6775Labellabel
098-7614Label, Warninglabel
098-7877Label, Battery Warninglabel
098-7902-01Label, Logolabel
098-7902-03Label, Logolabel
098-7902-04Label, Logolabel
098-7904Label, Dangerlabel
098-8075Label, Groundlabel
098-8144Label, Informationlabel
098-8204Label, Warninglabel
098-8220Label, Informationlabel
098-8445Label, Informationlabel
098-8732-02Label, Informationlabel
098-8940Label, Warninglabel
A029M832Label, Warninglabel
A029S884Label, Informationlabel
A029Z072Label, Informationlabel
LF9050Lube, Combinationoil_filter
0130-5997-05Cummins Part No. 312/212, 37564; Cummins Part No. 312/212, 37604; Cummins Part No. 212, 37558; Cummins Part No. 212, 37614; Cummins Part No. 212, 37627; Cummins Part No. 313/312, 0179-2921; Cummins Part No. 313/312, 0179-2988; Cummins Part No. 312, 0179-3291; Cummins Part No. 312/212, 130-5791; Cummins Part No. 312/212, 37644; Cummins Part No. 312/212, 37624; Cummins Part No. 312/212, 37625; Cummins Part No. 212, 37648; Cummins Part No. 212, 37643; Cummins Part No. 212, 37678; Cummins Part No. 212, 37665; Cummins Part No. 312/212, 37676; Cummins Part No. 312/212, 37610; Cummins Part No. 313/212, 37642other_service
0179-2862Nema 284T frame has the following arrangement: 6311 C3 / 18gram Polyrex – EM /20,000hother_service
0179-3291Nema 284T frame has the following arrangement: 6311 C3 / 11gram Polyrex – EM /20,000hother_service
130-5077-02Tube, Heaterother_service
130-5078-02Tube, Heaterother_service
130-5079-02Tube, Heaterother_service
130-5080-02Tube, Heaterother_service
130-5089-02Tube, Heaterother_service
323-1491* Pin, Contact (Used With Inline G)other_service
323-1492* Socket, Contact (Used In Stations 18, 19)other_service
323-1688* Socket, Contact (Used In P1)other_service
323-1718* Pin, Contact (Used In Station 17)other_service
4-2002PowerCommand Controlother_service
416-1019Boot, Battery (Red)other_service
518-0548-24Clamp, Retainer Begin December 1996 Production (Mounted On Top And Side Of Control Box Wrapper On The Side Towards The Control Box Cover)other_service
518-0601Sealant, Thread (6 ml Tube)other_service
525-0304Onan Green Enamel (Non-Metallic) - Gallon Canother_service
525-030512 oz. Pressurized Spray Canother_service
525-0306Onan Green Enamel (Non-Metallic) - Quart Canother_service
5410770Cummins enclosed C2000D5 diesel generator set powered by QSK60G3 engine provides reliable continuous power for Bab Gas Compression Facility.other_service
898-1254-25Sleeving – Heater Leads (59”)other_service
960-0161other_service
A026N045Bracket, Mountingother_service
A026N055Bracket, Mountingother_service
A026N058Leg, Boxother_service
A026N061Leg, Boxother_service
A026N070Panel, Coverother_service
A029F250Insulation, Ductother_service
A029F255Insulation, Ductother_service
A029S366Lead, Groundother_service
A029Y658Studother_service
A040C685Bracket, Supportother_service
A041U339Shim, Generator Mountingother_service
A041U341Shim, Generator Mountingother_service
A056A610RECOMMENDED SPARES LIST (RSL) FOR DQKAD GENERATOR SETSother_service
A056A611RECOMMENDED SPARES LIST (RSL) FOR DQKAE GENERATOR SETSother_service
A056A612RECOMMENDED SPARES LIST (RSL) FOR DQKAF GENERATOR SETSother_service
A056F840Recommended Spares List (RSL) for DQKAN Generator Setsother_service
M-3089173Bushing - Camshaftother_service
M-4007741Bushing - Camshaftother_service
M-4089083Single Cylinder Headother_service
M-4089200Juego de Junta Modul. N. ° de Piezaother_service
M-4089201Juego Posenfriador Cuadrante N. ° de Piezaother_service
M-4089202Juego Sistema Enfriamiento N. ° de Piezaother_service
M-4089231Juego de Junta Modul. N. ° de Piezaother_service
M-4089232Juego Posenfriador Cuadrante N. ° de Piezaother_service
M-4089307Juego Bomba Inferior N. ° de Piezaother_service
M-4089308Juego Combustible Inferior N. ° de Piezaother_service
M-4089508Juego de Junta Modul. N. ° de Piezaother_service
M-4089509Juego Sistema Enfriamiento N. ° de Piezaother_service
M-4089874Juego Bloque Inferior N. ° de Piezaother_service
M-4955369Juego Posenfriador Cuadrante N. ° de Piezaother_service
M-4955370Juego de Junta Modul. N. ° de Piezaother_service
M-4956000Culata Cilindro Simple N. ° de Pieza ARother_service
A054B161Schematic Diagramschematic_diagram
323-1445* Seal, Cable (Used With Station 17)seal
323-1708# Seal, Cable (P8)seal
503-2129-05Line, Vent – Flexible – With One Male Pipe Swivel and One Female Pipe Swivel With O–Ring Face Seal (1/4” ID x 94–1/2”) Right Sideseal
509-0283-01Sealseal
193-0486Sender, Low Coolant Levelsensor
338-3832Harness, Wiring – Low Coolant Level Sender (4 Wire, 169”) (Includes Parts Marked *)sensor
AM47478880Temperature Sender, Exhaust Temperature Replaces 47367178, 87482353, LB52S00001P1sensor
AM47520140Sensor, 8-Pin/NH3/Ammonia Replaces 47368956, 84382712sensor
AM47520143Sensor, Def/AdBlue Quality Replaces 84553250sensor
AM504372225Sensor, MAP Temperature/Pressure Replaces 2852821, 4896794, 504073323sensor
M-3331970Spacer Gasket for QSK45 and QSK60 Engine applicationsspacer_gasket
309-0649Thermostatthermostat
309-0711Thermostatthermostat
M-4089203Juego Turbo e Interenfriador N. ° de Piezaturbocharger
M-4089233Juego Turbo e Interenfriador N. ° de Piezaturbocharger

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

Which generators use the Cummins/Onan QSK60-G6 (2P/2L) engine?

The Cummins/Onan QSK60-G6 (2P/2L) powers 1 generator set(s), including Cummins/Onan DQKC.

What is a common problem with the Cummins/Onan QSK60-G6 (2P/2L) engine?

A commonly reported issue on generators using the Cummins/Onan QSK60-G6 (2P/2L) is: Time press sensor low.