| Clearance | Lower plunger diameter | 11 | mm | |
| Clearance | Lower plunger stroke | 10 | mm | |
| Clearance | Timing and upper plunger diameter | 15 | mm | |
| Clearance | Timing plunger separation (overtravel) maximum | 9 | mm | |
| Clearance | Timing plunger separation (overtravel) minimum | 2 | mm | |
| Clearance | Upper plunger travel for nose engagement | 5 | mm | |
| Other | DB9F-DB9M serial cable length (Part Number 4918418) | 1.83 | M | |
| Other | Extension DB9F to DB9M length (Part Number 3162851) | 30.48 | M | |
| Other | Fuel filter water separator element filtration rating | 10 | microns | |
| Other | Fuel rail actuator maximum flow rate | 1000 | pounds per hour | |
| Other | INLINE™5 datalink adapter current requirement | 250 | mA | at +8 VDC to +50 VDC |
| Other | Timing chamber pressure relative to injection pressure | 50 | % | |
| Other | Timing rail actuator maximum flow rate | 1500 | pounds per hour | |
| Other | Typical drain fuel flow rate | 2 | GPM | |
| Other | USB cable length (Part Number 4918419) | 2 | M | |
| Other | USB cable length (Part Number 4918591) | 5 | M | |
| Pressure | Cooling radiator maximum restriction | 5 | PSI | |
| Pressure | Cup pressure example | 25,000 | PSI | when timing chamber pressure is 12,500 PSI |
| Pressure | Fuel rail pressure maximum | 290 | psi | |
| Pressure | Fuel rail pressure minimum | 2 | psi | |
| Pressure | Future injector injection pressure capability | 35,000 | psi | |
| Pressure | Injection pressure (CELECT) | 22,500 | PSI | |
| Pressure | Injection pressure (PT) | 18,000 | PSI | |
| Pressure | Injection pressure (Quantum) | 25,000 | PSI | |
| Pressure | Maximum fuel inlet restriction at filters (clean filter) | 4 | inHg | |
| Pressure | Maximum fuel inlet restriction at filters (dirty filter) | 8 | inHg | |
| Pressure | Timing chamber pressure example | 12,500 | PSI | when cup pressure is 25,000 PSI |
| Temperature | Fuel cooler thermostat closed temperature | 89 | °F | |
| Temperature | Fuel cooler thermostat fully opened temperature | 104 | °F | |
| Temperature | Fuel cooler thermostat starts to open temperature | 90 | °F | |
| Voltage | INLINE™5 datalink adapter supply voltage (maximum) | +50 | VDC | power lamp fast flashing indicates greater than maximum |
| Voltage | INLINE™5 datalink adapter supply voltage (minimum) | +8 | VDC | power lamp slow flashing indicates less than minimum |