| Other | Cold cranking amperes (CCA) - engine only (de-clutched load) | 900 | CCA | |
| Other | Reserve capacity - engine only (de-clutched load) | 320 | min. | |
| Pressure | Maximum allowable exhaust back pressure | 2 (50) | in. Hg. (mm Hg) | |
| Pressure | Maximum allowable intake air restriction with heavy duty air cleaner - clean element | 8 (203) | in. H2O (mm H2O) | clean element |
| Pressure | Maximum allowable intake air restriction with heavy duty air cleaner - dirty element | 15 (381) | in. H2O (mm H2O) | dirty element |
| Pressure | Maximum coolant friction head external to the engine | 5 (34) | PSI (kPa) | |
| Pressure | Maximum running pressure to carburetor (after regulation) | 6 (152) | in. H2O (mm H2O) | |
| Pressure | Maximum running pressure to engine mounted regulator | 20 (508) | in. H2O (mm H2O) | |
| Pressure | Minimum allowable pressure cap | 7 (48) | PSI (kPa) | |
| Pressure | Minimum running pressure to engine mounted regulator | 10 (254) | in. H2O (mm H2O) | |
| Pressure | Oil pressure at idle (minimum allowable) | 15 (103) | PSI (kPa) | idle |
| Pressure | Oil pressure at rated speed (minimum allowable) | 35 – 45 (241 – 310) | PSI (kPa) | rated speed |
| Pressure | SAE J1349 test condition: barometric pressure | 29.61 | in. Hg | 100 kPa; 300 ft (91 m) altitude |
| Pressure | SAE J1349 test condition: water pressure | 0.30 | in. Hg | 1 kPa |
| Resistance | Maximum allowable resistance of starting circuit | 002 | Ohms | |
| Speed | Low idle speed | 900 | RPM | |
| Speed | Maximum no-load governed speed | 1980 | RPM | |
| Speed | Maximum overspeed capability | 2100 | RPM | |
| Speed | Maximum rated speed | 1800 | RPM | |
| Speed | Minimum cranking speed | 150 | RPM | |
| Temperature | Maximum allowable oil temperature | 230 (110) | °F (°C) | |
| Temperature | Maximum allowable top tank temperature | 200 (93) | °F (°C) | |
| Temperature | Maximum turbine inlet temp (dry manifold) | 1300 (704) | °F (°C) | |
| Temperature | Minimum recommended top tank temperature | 160 (71) | °F (°C) | |
| Temperature | Rating note (1): water temperature to aftercooler, or use of air-to-air aftercooler with 100 F or lower air temperature to the radiator | 32 | C (90 F) | applies to 10.5:1 / 10:1 / 11:1 note-(1) ratings |
| Temperature | Rating note (2): water temperature to aftercooler, or use of air-to-air aftercooler with 130 F or lower air temperature to the radiator | 54 | C (130 F) | applies to 8.5:1 note-(2) ratings |
| Temperature | Rating note (3): water temperature to aftercooler, or use of air-to-air aftercooler with 110 F or lower air temperature to the radiator | 32 | C (90 F) | applies to 10.5:1 note-(3) ratings |
| Temperature | Rating note (4): water temperature to aftercooler, or use of air-to-air aftercooler with 130 F or lower air temperature to the radiator | 54 | C (130 F) | applies to 8.5:1 note-(4) ratings |
| Temperature | SAE J1349 test condition: inlet air temperature | 77 | F | 25 C |
| Temperature | Standard thermostat (modulating) range | 175 – 195 (79 – 91) | °F (°C) | |
| Voltage | Minimum recommended battery capacity (cold soak 0° F / -18° C or above) | 24 | Volt | |