Cummins/Onan E095H-G Engine

The Cummins/Onan E095H-G is a 1.6 L 1-cylinder ohv engine rated at 3600 rpm. It powers generator sets from Cummins/Onan, including the 4000 KY and MicroLiteTM 4000 Series. It holds 1.6 L (0.4 gal) of oil.

Also known as: Onan E095H-G

Part of the Cummins/Onan E095H engine family — 2 variants share parts & fitment.

1.6 L
Displacement
1
Cylinders
3600 rpm
Rated speed
1.6 L
Oil capacity

Engine specifications

Oil capacity1.6 L
Displacement1.6 L
Cylinders1
AspirationOHV
Rated speed3600 rpm

Generator sets powered by this engine

2
Cummins/Onan 4000 KYCummins/Onan MicroLiteTM 4000 Series

How to read your Cummins/Onan engine serial & model number →

Common problems

5
  • Weakness and Sleepiness
    Fix: IF YOU OR ANYONE ELSE EXPERIENCE ANY OF THESE SYMPTOMS, GET OUT INTO THE FRESH AIR IMMEDIATELY. if symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired.
  • Vomiting
    Fix: IF YOU OR ANYONE ELSE EXPERIENCE ANY OF THESE SYMPTOMS, GET OUT INTO THE FRESH AIR IMMEDIATELY. if symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired.
  • Muscular Twitching
    Fix: IF YOU OR ANYONE ELSE EXPERIENCE ANY OF THESE SYMPTOMS, GET OUT INTO THE FRESH AIR IMMEDIATELY. if symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired.
  • Inability to Think Coherently
    Fix: IF YOU OR ANYONE ELSE EXPERIENCE ANY OF THESE SYMPTOMS, GET OUT INTO THE FRESH AIR IMMEDIATELY. if symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired.
  • Dizziness
    Fix: IF YOU OR ANYONE ELSE EXPERIENCE ANY OF THESE SYMPTOMS, GET OUT INTO THE FRESH AIR IMMEDIATELY. if symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired.

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan E095H-G.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filter—500 hr
Fuel filter—100 hr
Oil filter—50 hr
BatteryCheck specific gravity, charge if necessary—
Belt—
Coolant—
Oil1.6 quarts (1.5 litres)—50 hr
Spark plug—1000 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

6
ItemActionHoursMonthsNotes
Battery terminals and cable connectorsCheckFirst service — Before starting; clean and dry.
Engine oil levelCheckFirst service — Before starting; add oil slowly to Full mark if low.
Exhaust system leaksInspectFirst service — After initial start; audible and visual inspection.
Fuel leaksInspectFirst service — After initial start; stop set immediately if leaks are found.
Fuel supply valveOtherFirst service — Open if equipped before starting.
Installation reviewInspectFirst service — Prior to initial start-up; all answers must be yes.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

7
TypeItemValueUnitCondition
ClearanceExhaust system to combustible material3 inches (76 mm)minimum
ClearanceMounting bolt protrusion into base1/2 inch (13 mm)maximum
GapSpark plug gap0.025 in. (0.64 mm)
PressureLPG fuel system leak test pressure90 psi (620 kPa)test pressure
SpeedEngine speed3600rpm
Torque5/16 inch mounting screws15 ft lbs (20 N·m)
VoltageBattery cable voltage drop0.12 volts per 100 ampereswhile cranking

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
FuelCommercial propane or HD-5 grade LPGat least 90 percent propaneUse LPG vapor; regulator required between cylinder and genset.
FuelRegular grade gasolineUse clean, fresh regular grade gasoline.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

10
LPG Fuel System Leak Test diagnostic

⚠ Do not smoke or allow flame, spark, pilot light, or arc-producing equipment near fuel.

  1. After assembly and before initial operation, test all fuel system connections, hose, valves, regulators, and fittings.
  2. Use soap-and-water or equivalent solution while system is under gas or air pressure of at least 90 psi (620 kPa).
  3. Other approved leak-detection methods may be used if appropriate.
  4. Do not make this test with a flame.
Compartment Mounting installation

⚠ Exhaust gases can cause severe personal injury or death; make compartment walls vapor-tight.

Tools: Onan template 539-1383

  1. Install the genset in its own compartment; use vapor-tight walls if any part is above the vehicle floor.
  2. Measure compartment size for proper clearance; add 1/2 inch depth if 1/2-inch insulation is used.
  3. Put holes in compartment bottom for genset mounting, air outlet, and oil drain.
  4. Put holes for fuel line, battery cable, remote control harness, and AC conduit.
  5. Mount genset with four 5/16-16 screws; maximum protrusion through base is 1/2 inch.
  6. Shield exposed above-floor exhaust pipe with the Onan-supplied exhaust shield.
Connect to Vehicle Systems installation

⚠ Do not connect battery cables until instructed in Initial Start and Checks.

  1. Route fuel line separate from electrical wires or separate them with conduit or sheathing.
  2. Gasoline: connect 1/4-inch I.D. SAE 30-R7 fuel hose to the barb fitting; secure with stainless steel clamp.
  3. LPG: connect 3/8-inch I.D. fuel hose to the barb fitting; secure with stainless steel clamp.
  4. Install listed 1/2-inch flexible conduit over AC wiring and secure to genset fitting.
  5. Connect battery positive cable to B+ connection on start solenoid.
  6. Connect battery negative cable with 3/8-inch ring terminal to ground on left side of base.
  7. Route remote control connector through left-side access opening and connect to mating connector.
Exhaust System Connection installation

⚠ Exhaust gas presents the hazard of severe personal injury or death.

Tools: U-bolt clamp

  1. Connect installer-supplied 1-1/2-inch O.D. (1-3/8-inch I.D.) exhaust pipe to genset with a U-bolt clamp.
  2. Do not terminate the exhaust tail pipe under the vehicle.
  3. Extend tail pipe at least 1 inch (25.4 mm) beyond the side or end of vehicle.
  4. Support tail pipe as close as possible to outside of vehicle.
  5. Protect tail pipe below departure angle with skid bar, trailer hitch, or frame member.
  6. Ensure no vent, window, or opening into living area is within the triangular area.
Preparation installation
  1. Pry the bottom of the crate sides and ends out from the wooden skid base.
  2. Carefully lift the crate off the genset and discard it.
  3. Remove the plastic bag and collect loose shipped items such as the Operator's Manual.
  4. Remove mounting bolts securing the wooden skid to the genset base ends.
Under-Floor Mounting installation

⚠ Dropping the generator set can cause severe personal injury or death.

Tools: Forklift

  1. Use the template to locate holes in the vehicle support structure.
  2. If area above compartment is wood, install 26-gauge galvanized metal plate above genset.
  3. Assemble the Under-Floor Housing kit according to its instructions.
  4. Securely mount hanger brackets and side panels to the under-floor support structure.
  5. Assemble front and back rails to the genset.
  6. Use a forklift to carefully raise the genset into the support frame.
  7. Secure rails to support frame with mounting hardware included in the kit.
Pre-Start Checks maintenance

⚠ Batteries produce explosive gas; do not smoke or allow arc-producing devices in battery area.

  1. Perform the Installation Review described in this section.
  2. Check engine oil level; remove and clean indicator, insert into filler neck, add oil slowly to Full mark if low.
  3. Check battery terminals and cable connectors are clean and dry.
  4. Connect positive battery cable first, then negative cable last.
  5. Review the Operator's Manual and open fuel supply valve if equipped.
Remove and Secure Access Cover maintenance

⚠ Do not operate the generator set with the access cover removed.

  1. Rotate access cover fasteners one-quarter turn clockwise so arrows point right.
  2. Pull the top of the cover away from the housing.
  3. To secure, position the bottom of the cover over the base.
  4. Push the top in and turn fasteners one-quarter turn counterclockwise so arrows point up.
Initial Start from Remote Control operation
  1. Move Remote Start/Stop switch to START.
  2. Engine should crank and start as indicated by indicator light on switch.
  3. If it does not, check all remote control connections, repair if necessary, and restart.
  4. Check battery condition meter if equipped.
  5. Move Start/Stop switch to STOP to stop set.
Initial Start from Set Mounted Control operation

⚠ Do not operate generator set inside any room or building.

  1. Move Start/Stop switch to START; engine should crank and start.
  2. Allow more cranking if needed to prime fuel system.
  3. After start, check for fuel leaks; stop set immediately if leaks are found.
  4. Examine exhaust system for leaks; stop set and repair immediately if leaks are found.
  5. Operate set with normal load and monitor fuel supply, exhaust, performance, and noise.
  6. Move Start/Stop switch to STOP to stop set.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Cummins/Onan E095H family

6
Part #DescriptionCategory
981-0627Fuel FilterFuel filter
16443Housing, Air Cleaner Metal - w/Filter ElementHousing air cleaner metal with filter element
M1900-4OIL CHANGEOil
MI8964Oil Level IndicatorOil level indicator
M1896-6CARBURETOR ALTITUDE ADJUSTMENTService part / kit
15822Radiator ShroudRadiator shroud

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

What is the oil capacity of the Cummins/Onan E095H-G?

The Cummins/Onan E095H-G engine has an oil capacity of 1.6 liters.

What is the displacement of the Cummins/Onan E095H-G?

The Cummins/Onan E095H-G has a displacement of 1.6 liters with 1 cylinders.

Which generators use the Cummins/Onan E095H-G engine?

The Cummins/Onan E095H-G powers 2 generator set(s), including Cummins/Onan 4000 KY, Cummins/Onan MicroLiteTM 4000 Series.

How often should you change the oil in the Cummins/Onan E095H-G?

The Cummins/Onan E095H-G oil change interval is every 50 hours.

What is a common problem with the Cummins/Onan E095H-G engine?

A commonly reported issue on generators using the Cummins/Onan E095H-G is: Weakness and Sleepiness. Fix: IF YOU OR ANYONE ELSE EXPERIENCE ANY OF THESE SYMPTOMS, GET OUT INTO THE FRESH AIR IMMEDIATELY. if symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired..