Home›Engines›Continental F226

Continental F226 Engine

The Continental F226 is a 0.79 L gasoline engine rated at 1800 rpm, producing up to 54.2 kW. It powers generator sets from Aurora Generators, including the 25HN. It holds 6 L (1.6 gal) of oil and 17 L (4.5 gal) of coolant.

Also known as: Continental F226

Part of the Continental F226 engine family — 3 variants share parts & fitment.

0.794 L
Displacement
1800 rpm
Rated speed
54 kW
Gross power
6.0 L
Oil capacity

Engine specifications

Oil capacity6.0 L
Coolant capacity17.0 L
Displacement0.794 L
Aspirationgasoline
Rated speed1800 rpm
Gross power54 kW

Generator sets powered by this engine

1

Common problems

15
  • Excessive oil consumption, light blue smoky exhaust
    Cause: Worn piston rings
    Fix: Install new piston rings
  • Low oil pressure
    Cause: Oil too light
    Fix: Drain, refill with proper oil
  • Engine will not start when cranked
    Cause: Faulty ignition
    Fix: Clean, adjust, or replace breaker points, plugs, condenser, coil, etc. or retime ignition
  • Pinging sound when engine is rapidly accelerated or heavily loaded
    Cause: Carbon in cylinders
    Fix: Remove carbon
  • Engine backfires at carburetor
    Cause: Lean fuel mixture
    Fix: Clean carburetor
  • Engine overheating
    Cause: Low water in radiator
    Fix: Refill radiator
  • Engine misfires at light load
    Cause: Carburetor idle adjustment set wrong or clogged
    Fix: Adjust, clean if needed
  • Engine misfires at all loads
    Cause: Fouled spark plug
    Fix: Clean and adjust
  • Engine misfires at heavy load
    Cause: Spark plugs defective
    Fix: Replace
  • Light pounding knock
    Cause: Loose connecting rod bearing
    Fix: Replace
  • High oil pressure
    Cause: Oil too heavy
    Fix: Drain, refill with proper oil
  • Excessive arcing of brushes
    Cause: Rough commutator or rings
    Fix: Turn down
  • Engine stops unexpectedly
    Cause: Fuel tank empty
    Fix: Refill
  • Current unsteady but engine not misfiring
    Cause: Speed too low
    Fix: Adjust governor to correct speed
  • Sharp metallic thud, especially when cold engine first started
    Cause: Low oil supply
    Fix: Add oil

Compiled from service & troubleshooting documentation across every generator set that uses the Continental F226.

Also used in

12
  • Barber-Greene 772 — Trencher
  • Barber-Greene 773 — Trencher
  • Clark 35A — Loader Wheeled
  • Clark 35AWS — Loader Wheeled
  • Clark 35B — Loader Wheeled
  • Gardner Denver SP125 — Compressor
  • Hyster H60 — Forklift
  • Hyster H60C — Forklift
  • Hyster H70 — Forklift
  • Hyster H70C — Forklift
  • Hyster H80 — Forklift
  • Hyster H80C — Forklift

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Continental F226?

The Continental F226 engine has an oil capacity of 6.0 liters.

What is the displacement of the Continental F226?

The Continental F226 has a displacement of 0.794 liters.

Which generators use the Continental F226 engine?

The Continental F226 powers 1 generator set(s), including Aurora Generators 25HN.

What is a common problem with the Continental F226 engine?

A commonly reported issue on generators using the Continental F226 is: Excessive oil consumption, light blue smoky exhaust. Cause: Worn piston rings. Fix: Install new piston rings.