| Other | Air compressor air flow | 374 | L/min (13.2 cfm) @ 1250 rpm | C7 ACERT, C9 ACERT |
| Other | Air compressor air flow | 445 | L/min (15.7 cfm) @ 1250 rpm | C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT |
| Other | Air compressor air flow | 467 | L/min (16.5 cfm) @ 1250 rpm | C7 ACERT, C9 ACERT |
| Other | Air compressor air flow | 889 | L/min (31.4 cfm) @ 1250 rpm | C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT |
| Other | Compression Ratio | 15.0:1 | | |
| Other | Radiator cooling package maximum elevation | 1524 | m (5000 ft) | with 50/50 water/Extended Life Coolant mixture |
| Other | Rating condition (diesel 7 L and higher) | 99 kPa (29.31 in Hg) dry barometer, 25°C (77°F) | | SAE J1995 inlet air standard |
| Other | Rating condition (diesel up to 6.6 L) | 100 kPa (29.5 in Hg) total barometric pressure, 1 kPa (.295 in Hg) vapor pressure, 25°C (77°F) | | ISO/TR14396 inlet air standard |
| Other | Rating condition (gas) | 100 kPa (29.61 in Hg) and 25°C (77°F) | | SAE J1349 standard |
| Other | Rotation (from flywheel end) | Counterclockwise | | from flywheel end |
| Pressure | Attachments gear-type pump output pressure | 6895 | kPa | at 1,890 rpm |
| Pressure | Bulldozer relief valve setting | 22 750 | kPa | |
| Pressure | CarryDozer relief valve setting | 24 135 | kPa | |
| Pressure | Dump cylinder relief valve setting | 24 825 | kPa | |
| Pressure | Ripper (lift) relief valve setting | 22 750 | kPa | |
| Pressure | Ripper (lift) relief valve setting | 24 135 | kPa | |
| Pressure | Ripper (pitch) relief valve setting | 22 750 | kPa | |
| Pressure | Ripper (pitch) relief valve setting | 24 135 | kPa | |
| Pressure | Tilt cylinder relief valve setting | 24 300 | kPa | |
| Speed | Attachments gear-type pump output (D11T CD) | 670 | L/min | at 1,890 rpm |
| Speed | Attachments gear-type pump output (D11T) | 620 | L/min | at 1,890 rpm |
| Speed | Flexible Rated Speed | 1800-2100 | rpm | |
| Speed | Peak Torque Speed | 1400 | rpm | |
| Speed | Tilt cylinder flow (D11T CD) | 250 | L/min | |
| Speed | Tilt cylinder flow (D11T) | 155 | L/min | |
| Temperature | Radiator cooling package design ambient temperature | 48.9 | °C (120°F) | coolant mixture 50/50 (water/Caterpillar Extended Life Coolant), maximum elevation 1524 m (5000 ft) |
| Torque | Air compressor SAE "A" hydraulic pump drive maximum torque (374 L/min and 467 L/min compressors) | 60 | N•m (44 lb-ft) | C7, C9 ACERT |
| Torque | Air compressor maximum torque (374 L/min / 13.2 cfm @ 1250 rpm, C7/C9) | 60 | N·m (44 lb-ft) | 374 L/min (13.2 cfm) @ 1250 rpm |
| Torque | Air compressor maximum torque (467 L/min / 16.5 cfm @ 1250 rpm, C7/C9) | 60 | N·m (44 lb-ft) | 467 L/min (16.5 cfm) @ 1250 rpm |