| Clearance | Coolant level below bottom of filler pipe / below sight glass level | 13 | mm | engine stopped and cool |
| Clearance | Unit injector height (from top of unit injector to machined ledge of fuel injector body) | 78.0 ± 0.2 | mm | |
| Other | Air cleaner service indicator reset attempts before replacement | 3 | pushes | |
| Other | Air compressor air flow | 374 | L/min (13.2 cfm) @ 1250 rpm | C7 ACERT, C9 ACERT |
| Other | Air compressor air flow | 445 | L/min (15.7 cfm) @ 1250 rpm | C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT |
| Other | Air compressor air flow | 467 | L/min (16.5 cfm) @ 1250 rpm | C7 ACERT, C9 ACERT |
| Other | Air compressor air flow | 889 | L/min (31.4 cfm) @ 1250 rpm | C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT |
| Other | Cooling system fill rate, maximum | 19 | L/min | to avoid air locks |
| Other | Radiator cooling package maximum elevation | 1524 | m (5000 ft) | with 50/50 water/Extended Life Coolant mixture |
| Other | Rating condition (diesel 7 L and higher) | 99 kPa (29.31 in Hg) dry barometer, 25°C (77°F) | | SAE J1995 inlet air standard |
| Other | Rating condition (diesel up to 6.6 L) | 100 kPa (29.5 in Hg) total barometric pressure, 1 kPa (.295 in Hg) vapor pressure, 25°C (77°F) | | ISO/TR14396 inlet air standard |
| Other | Rating condition (gas) | 100 kPa (29.61 in Hg) and 25°C (77°F) | | SAE J1349 standard |
| Pressure | Air cleaner element cleaning, maximum air pressure | 207 | kPa | |
| Pressure | Air cleaner service indicator restriction | 762 ± 6 | mm H2O | |
| Pressure | Fuel system primary filter/water separator element change pressure | 50 to 70 | kPa | |
| Pressure | Maximum air pressure at nozzle for cleaning purposes | 205 | kPa | |
| Pressure | Maximum air pressure for cleaning purposes (deadheaded air nozzle with chip guarding and PPE) | 205 | kPa | |
| Pressure | Maximum air pressure for cleaning purposes (deadheaded air nozzle with chip guarding and PPE) | 30 | psi | |
| Pressure | Maximum water pressure for cleaning purposes | 275 | kPa | |
| Pressure | Maximum water pressure for cleaning purposes | 40 | psi | |
| Pressure | Maximum water pressure for radiator cleaning | 275 | kPa | |
| Pressure | Unit injector fuel injection pressure | 1240 | bar (18 000 psi) | |
| Resistance | Exciter armature (rotor) winding (L2) | less than 0.1 | ohm | |
| Resistance | Exciter field (stator) winding (L1) | approximately 3.0 to 6.0 | ohms | winding at room temperature |
| Resistance | Insulation resistance, minimum (generators below 1000 V) | 1 | megohm | |
| Resistance | Main armature (stator) winding (L4) | less than 0.1 | ohm | |
| Resistance | Main field (rotor) winding (L3) | approximately 0.75 to 2.0 | ohms | winding at room temperature |
| Resistance | Pilot exciter armature winding (L5) | less than 0.1 | ohm | |
| Resistance | Rectifier diode meter reading | 0.4 to 1.0 | | digital multimeter on diode range |
| Resistance | Varistor (CR7) resistance, minimum | 15000 | ohms | |
| Speed | Engine speed to purge air from engine block cavities | 1500 | rpm | operate for one minute |
| Temperature | Bearing temperature rise above ambient, maximum | 60 | °C | certain frame sizes |
| Temperature | Coolant temperature during cooling system flush | at least 82 | °C | |
| Temperature | Generator bearing temperature - alarm | 85 | °C | |
| Temperature | Generator bearing temperature - shutdown | 95 | °C | |
| Temperature | Generator drying temperature | 75 | °C | do not exceed until insulation resistance tests correctly (at least 4 hours) |
| Temperature | Insulation and winding temperature rise limit when drying | 11.11 | °C per hour | |
| Temperature | Jacket water coolant temperature at 0 °C (32 °F) ambient | approximately 32 | °C | ambient 0 °C (32 °F) |
| Temperature | Maximum storage temperature for ether cylinders | 120 | °F | |
| Temperature | Maximum storage temperature for ether cylinders | 49 | °C | |
| Temperature | Maximum storage temperature for ether cylinders (Engine Starting section) | 102 | °F | |
| Temperature | Maximum storage temperature for ether cylinders (Engine Starting section) | 39 | °C | |
| Temperature | Radiator cooling package design ambient temperature | 48.9 | °C (120°F) | coolant mixture 50/50 (water/Caterpillar Extended Life Coolant), maximum elevation 1524 m (5000 ft) |
| Temperature | Stator winding setpoint, continuous - alarm | 155 | °C | continuous application |
| Temperature | Stator winding setpoint, continuous - shutdown | 165 | °C | continuous application |
| Temperature | Stator winding setpoint, standby - alarm | 180 | °C | standby application |
| Temperature | Stator winding setpoint, standby - shutdown | 190 | °C | standby application |
| Torque | Air compressor SAE "A" hydraulic pump drive maximum torque (374 L/min and 467 L/min compressors) | 60 | N•m (44 lb-ft) | C7, C9 ACERT |
| Torque | Air compressor maximum torque (374 L/min / 13.2 cfm @ 1250 rpm, C7/C9) | 60 | N·m (44 lb-ft) | 374 L/min (13.2 cfm) @ 1250 rpm |
| Torque | Air compressor maximum torque (467 L/min / 16.5 cfm @ 1250 rpm, C7/C9) | 60 | N·m (44 lb-ft) | 467 L/min (16.5 cfm) @ 1250 rpm |
| Torque | Bearing Nut Torque (129-3253 Spanner Socket, 121-9871 Bearing Nut) | 2375 | N·m | |
| Torque | Bearing Nut Torque (129-3254 Spanner Socket, 119-3711 Bearing Nut) | 2375 | N·m | |
| Torque | Engine oil drain plug | 70 ± 14 | N·m | |
| Torque | Locknut torque (260-0626 Spanner Socket Assembly, 1T-0229 High Torque Locknut) | 985 | N·m | |
| Torque | Magnetic pickup locknut | 25 ± 5 | N·m | |
| Torque | Solenoid nut torque (FT3198 Solenoid Tool, 352-2733 solenoid) | 3.75 | Nm | +/- .75 |
| Torque | Tightening torque for 369-5916 Lifting Eyebolt (M12 Hex Bit) | 115 | N·m | |
| Torque | Unit injector adjustment locknut | 100 ± 10 | N·m | |
| Torque | Water separator bowl assembly onto new fuel filter | 15 | N·m | |
| Torque | Working torque capacity of locknut spanner wrenches (126-6608 / 126-6609) | 950 | N·m | |