Allis-Chalmers 6138-LT Engine
The Allis-Chalmers 6138-LT is a 13.8 L 6-cylinder turbocharged engine rated at 1800 rpm, producing up to 276 kW. It powers generator sets from Cummins/Onan, including the 150.0 DYG 15R.
Also known as: Allis-Chalmers 6138-LT
Engine specifications
| Displacement | 13.8 L |
|---|
| Cylinders | 6 |
|---|
| Aspiration | Turbocharged |
|---|
| Rated speed | 1800 rpm |
|---|
| Gross power | 276 kW |
|---|
Generator sets powered by this engine
1
Common problems
8- Overcrank fault lamp lights and engine stops cranking after approximately 75-seconds.
Fix: See engine service manual for troubleshooting fuel system. After correcting fault, reset engine monitor relay by placing Run-Stop/Reset-Remote switch to Stop/Reset position, depressing Reset button, then to the required running position. - Low oil pressure shutdown.
Fix: A. Oil level. Replenish if necessary. b. Sensor. Faulty sensor will shut down engine. c. Refer to engine service manual for troubleshooting guide for oil system. - High engine temperature shutdown.
Fix: A. Coolant level. Replenish if necessary. - Fault lamp lights, no fault exists.
Fix: To check a no-fault condition, disconnect leads from TB11 terminals 29, 30 and 31. If fault lamp lights with leads disconnected, replace engine monitor board. Reconnect leads. - Fault lamp lights immediately after engine starts.
Fix: Check for: Overspeed condition as engine starts. - Fault lamp lights and engine shuts down after running for a period.
Fix: Check the following: a. Oil level. Engine will shut down if sensor is closed. b. Check engine manual for troubleshooting oil system. c. High engine temperature. Check coolant level; check water flow (city water cooled systems); check radiator for free air flow, and fan belts for tightness. See engine manual for troubleshooting cooling system. d. Check for faulty oil pressure sensor or faulty high engine temperature sensor. - Engine stops cranking and fault lamp lights, after cranking approximately 75 seconds.
Fix: See engine service manual for troubleshooting fuel system. After correcting problem, reset engine monitor relay by placing Run-Stop/Reset-Remote switch to Stop/Reset, then back to the required running position. - Engine runs, shuts down and cranks for 75-seconds. Cranking cycle stops; fault lamp lights.
Fix: Check fuel supply.
Compiled from service & troubleshooting documentation across every generator set that uses the Allis-Chalmers 6138-LT.
Also used in
1- Allis-Chalmers N7 — Combine
Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.
Common questions
What is the displacement of the Allis-Chalmers 6138-LT?
The Allis-Chalmers 6138-LT has a displacement of 13.8 liters with 6 cylinders.
Which generators use the Allis-Chalmers 6138-LT engine?
The Allis-Chalmers 6138-LT powers 1 generator set(s), including Cummins/Onan 150.0 DYG 15R.
What is a common problem with the Allis-Chalmers 6138-LT engine?
A commonly reported issue on generators using the Allis-Chalmers 6138-LT is: Overcrank fault lamp lights and engine stops cranking after approximately 75-seconds.. Fix: See engine service manual for troubleshooting fuel system. After correcting fault, reset engine monitor relay by placing Run-Stop/Reset-Remote switch to Stop/Reset position, depressing Reset button, then to the required running position..