Generac 004373-2 Engine Engine
The Generac 004373-2 is a natural engine. It powers generator sets from Generac, including the Guardian Liquid-cooled 40 kW Generator. It holds 4.25 L (1.1 gal) of oil.
Also known as: Generac 004373-2
Engine specifications
| Oil capacity | 4.25 L |
|---|
| Aspiration | Natural |
|---|
Generator sets powered by this engine
1
Common problems
4- The engine will not crank.
Cause: 1. Fuse blown 2. Loose, corroded or defective battery cables 3. Defective starter contactor 4. Defective starter motor 5. Dead Battery
Fix: 1. Replace fuse. 2. Tighten, clean or replace battery cables as necessary. 3. Replace defective starter contactor. 4. Replace defective starter motor. 5. Charge or replace battery. - The engine starts, but then shuts down.
Cause: 1. Engine oil level low 2. Defective low oil pressure switch 3. Defective high temperature switch 4. Defective control board 5. Low coolant
Fix: 1. Check oil and add oil as needed. 2. * 3. * 4. * 5. * - The engine starts hard and runs rough.
Cause: 1. Air cleaner plugged or damaged 2. Defective spark plug(s) 3. Dirty/Blocked air filter
Fix: 1. Check, clean or replace air cleaner. 2. Clean, re-gap or replace plug(s). 3. Clean or replace as required. - The engine cranks but will not start.
Cause: 1. Out of fuel 2. Defective fuel solenoid (FS) 3. Open #14 wire from engine control board 4. Defective spark plug(s) 5. Dirty/Blocked air filter
Fix: 1. Replenish fuel. 2. * 3. * 4. Clean, re-gap or replace plug(s). 5. Clean or replace as required.
Compiled from service & troubleshooting documentation across every generator set that uses the Generac 004373-2.
Common questions
What is the oil capacity of the Generac 004373-2?
The Generac 004373-2 engine has an oil capacity of 4.25 liters.
Which generators use the Generac 004373-2 engine?
The Generac 004373-2 powers 1 generator set(s), including Generac Guardian Liquid-cooled 40 kW Generator.
What is a common problem with the Generac 004373-2 engine?
A commonly reported issue on generators using the Generac 004373-2 is: The engine will not crank.. Cause: 1. Fuse blown 2. Loose, corroded or defective battery cables 3. Defective starter contactor 4. Defective starter motor 5. Dead Battery. Fix: 1. Replace fuse. 2. Tighten, clean or replace battery cables as necessary. 3. Replace defective starter contactor. 4. Replace defective starter motor. 5. Charge or replace battery..