The Cummins/Onan 4.0EGHAB is a 4 L natural engine rated at 3600 rpm. It powers generator sets from Cummins/Onan, including the 4.0 EGHAB. It holds 1.16 L (0.3 gal) of oil and 1.1 L (0.3 gal) of coolant.

Also known as: Onan 4.0EGHAB

4.0 L
Displacement
3600 rpm
Rated speed
1.16 L
Oil capacity

Engine specifications

Oil capacity1.16 L
Coolant capacity1.1 L
Displacement4.0 L
AspirationNatural
Rated speed3600 rpm

Generator sets powered by this engine

1

Common problems

12
  • UNIT RUNS THEN SURGES
    Cause: 1. Loose or worn spark plug lead 2. Faulty spark plug. 3. Dirty fuel filter or generator set at too steep of an angle. 4. Governor out of adjustment or lean fuel mixture.
    Fix: 1. Check spark plug lead connection. 2. Remove and clean or replace. 3. Check fuel filter and angle of generator set. 4. Contact an Onan service center.
  • UNIT RUNS THEN STOPS
    Fix: Add fuel. Add oil. Reduce oil level.
  • UNIT RUNS BUT SURGES
    Fix: Add fuel. Add oil. Reduce oil level.
  • NO DC OUTPUT VOLTAGE
    Cause: 1. Open DC circuit breaker due to an overload.
    Fix: 1. Remove all loads, reset breaker, check for shorted battery or load defects. Do not exceed rated load specifications.
  • NO AC OUTPUT VOLTAGE
    Cause: Open AC circuit breaker due to an overload
    Fix: Remove all loads, re-set circuit breaker, check tools or appliances being used for defects. Do not exceed generator set rated load specifications.
  • FAILS TO CRANK (ELECTRIC START MODELS)
    Cause: Low Battery, Bad battery connection, Oil is too heavy, Load is connected
    Fix: Check battery electrolyte level and charge. Clean and tighten all battery and cable connections. Replace with lighter oil. Always disconnect load while starting.
  • FAILS TO CRANK
    Cause: 1. Low battery. 2. Bad battery connection.
    Fix: 1. Check battery electrolyte level. 2. Clean and tighten all battery and cable connections.
  • EXHAUSTING BLACK SMOKE
    Cause: Open DC circuit breaker due to an overload
    Fix: Remove all loads, reset circuit breaker, check for an overload or short circuit. Do not exceed generator set rated load specifications.
  • ENGINE WON’T START
    Cause: 1. Fuel below genset pickup level in tank. 2. Fuel supply shutoff valve closed. 3. Remove spark plug and clean. 4. Add oil if necessary.
    Fix: 1. Add fuel. 2. Fully open fuel supply valve. 3. Replace with recommended oil. 4. Disconnect load while starting.
  • ENGINE WONT START
    Cause: Loose or worn spark plug lead, Faulty spark plug, Dirty fuel filter or generator set at too steep of an angle, Governor out of adjustment or lean fuel mix
    Fix: Check spark plug lead connection. Remove and clean or replace spark plug. Check fuel filter and generator set angle. Contact an Onan service center.
  • CRANKS SLOWLY (ELECTRIC START MODELS)
    Cause: Choke closed, Dirty air filter, Rich fuel mixture
    Fix: Open choke. Clean or replace air filter. Contact an Onan service center.
  • CRANKS SLOWLY
    Cause: 1. Low battery. 2. Bad battery connection.
    Fix: 1. Check battery electrolyte level. 2. Clean and tighten all battery and cable connections.

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan 4.0EGHAB.

Common questions

What is the oil capacity of the Cummins/Onan 4.0EGHAB?

The Cummins/Onan 4.0EGHAB engine has an oil capacity of 1.16 liters.

What is the displacement of the Cummins/Onan 4.0EGHAB?

The Cummins/Onan 4.0EGHAB has a displacement of 4.0 liters.

Which generators use the Cummins/Onan 4.0EGHAB engine?

The Cummins/Onan 4.0EGHAB powers 1 generator set(s), including Cummins/Onan 4.0 EGHAB.

What is a common problem with the Cummins/Onan 4.0EGHAB engine?

A commonly reported issue on generators using the Cummins/Onan 4.0EGHAB is: UNIT RUNS THEN SURGES. Cause: 1. Loose or worn spark plug lead 2. Faulty spark plug. 3. Dirty fuel filter or generator set at too steep of an angle. 4. Governor out of adjustment or lean fuel mixture.. Fix: 1. Check spark plug lead connection. 2. Remove and clean or replace. 3. Check fuel filter and angle of generator set. 4. Contact an Onan service center..