HomeEnginesCummins/Onan GS280-DG-A3

Cummins/Onan GS280-DG-A3 Engine Engine

The Cummins/Onan GS280-DG-A3 is a 0.28 L naturally_aspirated engine rated at 3600 rpm. It powers generator sets from Cummins/Onan, including the K3500. It holds 0.92 L (0.2 gal) of oil.

Also known as: Onan GS280-DG-A3

0.276 L
Displacement
3600 rpm
Rated speed
0.92 L
Oil capacity

Engine specifications

Oil capacity0.92 L
Displacement0.276 L
Aspirationnaturally_aspirated
Rated speed3600 rpm

Generator sets powered by this engine

1

Common problems

11
  • Only slight output voltage is delivered (3 ~ 6V)
    Cause: Worn brush or faulty contact surface of slip ring
    Fix: Clean brush contact and slip ring, or replace brush
  • Rated output voltage is not available
    Cause: Abnormal load circuit, blown circuit breaker (S.T.D., voltage 10%)
    Fix: Remove abnormality in load circuit and replace fuse
  • Pilot lamp does not light and output voltage is OV
    Cause: Faulty contact of receptacles or disconnected wiring inside of control box
    Fix: Repair or replace
  • Output voltage is not delivered
    Cause: Disconnected wiring
    Fix: Repair or replace stator coil, demagnetization of permanent magnet, clean brush contact and slip ring, repair or replace brush, or repair or replace sub coil
  • Output voltage is more than S.T.D. voltage by 30%
    Cause: Defective AVR
    Fix: Replace
  • Output voltage OV
    Fix: Set the switch to the desired AC or DC position
  • Generator set operates on a slight grade, and the fuel tank is completely filled.
    Fix: Do not fill completely if the generator set will operate on a slight grade.
  • Fuel level indicator looks damaged or loose.
    Fix: Install a new indicator before starting generator set.
  • Fluctuation of engine revolution is abnormal
    Cause: Disconnected or punctured AVR capacitor, faulty brush contact, excessive initial current, low engine output, faulty engine governor
    Fix: Replace capacitor, check for wear, wear amount, and contamination of contacting surface of brush and clean if necessary, repair or replace
  • Faulty electrical equipment connected to the generator presents an electrical shock hazard.
    Fix: Check all electrical equipment for frayed cords or breaks in the insulation before using. Properly applied and maintained ground fault circuit interrupters can afford additional protection against the hazard of electrical shock.
  • Crankcase pressure might blow out hot oil and cause serious burns.
    Fix: Do not attempt to check oil while the generator set is running. Add oil until it reaches the top of the oil port.

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan GS280-DG-A3.

Common questions

What is the oil capacity of the Cummins/Onan GS280-DG-A3?

The Cummins/Onan GS280-DG-A3 engine has an oil capacity of 0.92 liters.

What is the displacement of the Cummins/Onan GS280-DG-A3?

The Cummins/Onan GS280-DG-A3 has a displacement of 0.276 liters.

Which generators use the Cummins/Onan GS280-DG-A3 engine?

The Cummins/Onan GS280-DG-A3 powers 1 generator set(s), including Cummins/Onan K3500.

What is a common problem with the Cummins/Onan GS280-DG-A3 engine?

A commonly reported issue on generators using the Cummins/Onan GS280-DG-A3 is: Only slight output voltage is delivered (3 ~ 6V). Cause: Worn brush or faulty contact surface of slip ring. Fix: Clean brush contact and slip ring, or replace brush.