HomeEnginesCummins/Onan GN2500-DG-A3

Cummins/Onan GN2500-DG-A3 Engine Engine

The Cummins/Onan GN2500-DG-A3 is a 0.25 L naturally_aspirated engine rated at 3000 rpm. It powers generator sets from Cummins/Onan, including the K2500 and K3000.

Also known as: Onan GN2500-DG-A3

0.252 L
Displacement
3000 rpm
Rated speed

Engine specifications

Displacement0.252 L
Aspirationnaturally_aspirated
Rated speed3000 rpm

Generator sets powered by this engine

2

Common problems

11
  • Only slight output voltage is delivered (3 ~ 6V)
    Cause: Worn brush or faulty contact surface of slip ring
    Fix: Clean brush contact and slip ring, or replace brush
  • Rated output voltage is not available
    Cause: Abnormal load circuit, blown circuit breaker (S.T.D., voltage 10%)
    Fix: Remove abnormality in load circuit and replace fuse
  • Pilot lamp does not light and output voltage is OV
    Cause: Faulty contact of receptacles or disconnected wiring inside of control box
    Fix: Repair or replace
  • Output voltage is not delivered
    Cause: Disconnected wiring
    Fix: Repair or replace stator coil, demagnetization of permanent magnet, clean brush contact and slip ring, repair or replace brush, or repair or replace sub coil
  • Output voltage is more than S.T.D. voltage by 30%
    Cause: Defective AVR
    Fix: Replace
  • Output voltage OV
    Fix: Set the switch to the desired AC or DC position
  • Fluctuation of engine revolution is abnormal
    Cause: Disconnected or punctured AVR capacitor, faulty brush contact, excessive initial current, low engine output, faulty engine governor
    Fix: Replace capacitor, check for wear, wear amount, and contamination of contacting surface of brush and clean if necessary, repair or replace
  • Generator set operates on a slight grade, and the fuel tank is completely filled.
    Fix: Do not fill completely if the generator set will operate on a slight grade.
  • Fuel level indicator looks damaged or loose.
    Fix: Install a new indicator before starting generator set.
  • Faulty electrical equipment connected to the generator presents an electrical shock hazard.
    Fix: Check all electrical equipment for frayed cords or breaks in the insulation before using. Properly applied and maintained ground fault circuit interrupters can afford additional protection against the hazard of electrical shock.
  • Crankcase pressure might blow out hot oil and cause serious burns.
    Fix: Do not attempt to check oil while the generator set is running. Add oil until it reaches the top of the oil port.

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan GN2500-DG-A3.

Common questions

What is the displacement of the Cummins/Onan GN2500-DG-A3?

The Cummins/Onan GN2500-DG-A3 has a displacement of 0.252 liters.

Which generators use the Cummins/Onan GN2500-DG-A3 engine?

The Cummins/Onan GN2500-DG-A3 powers 2 generator set(s), including Cummins/Onan K2500, Cummins/Onan K3000.

What is a common problem with the Cummins/Onan GN2500-DG-A3 engine?

A commonly reported issue on generators using the Cummins/Onan GN2500-DG-A3 is: Only slight output voltage is delivered (3 ~ 6V). Cause: Worn brush or faulty contact surface of slip ring. Fix: Clean brush contact and slip ring, or replace brush.