HomeEnginesImpco GM 3.0L

Impco GM 3.0L Engine Engine

The Impco GM 3.0L is a 4-cylinder engine. It powers generator sets from Impco, including the GM 3.0.

Also known as: IMPCO GM 3.0L

4
Cylinders

Engine specifications

Cylinders4

Generator sets powered by this engine

1

Common problems

4
  • Fuel pressure issues
    Cause: Inadequate supply pressure to the fuel system low pressure regulator
    Fix: Check for negative pressure between -2.0” W.C. to -6.0” W.C., and ensure proper gas supply pressure
  • Engine running rich condition
    Cause: Constant positive pressure
    Fix: Ensure proper gas supply pressure
  • Engine running lean condition
    Cause: Negative pressure over -8.0 inches water
    Fix: Check fuel system low pressure regulator or supply pressure
  • Engine ignition system failure
    Cause: Spark plug, cap, rotor or wire fails
    Fix: No DTC code may be set

Compiled from service & troubleshooting documentation across every generator set that uses the Impco GM 3.0L.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterInspect and clean air cleaner every 200 hours or annually, more often in dusty environments200 hr find
Fuel filterReplace inline LPG filter every 2,000 hours or two years, whichever occurs first2000 hr find
Oil filterChange oil filter with every oil change100 hr find
BeltInspect accessory drive belts every 1000 hours or annually1000 hr find
CoolantChange coolant every 3500 hours or two years, whichever occurs first3500 hr
Coolant filter find
OilGM specification 9986231, ILSAC GF-4 oils preferred100 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Common questions

Which generators use the Impco GM 3.0L engine?

The Impco GM 3.0L powers 1 generator set(s), including Impco GM 3.0.

How often should you change the oil in the Impco GM 3.0L?

The Impco GM 3.0L oil change interval is every 100 hours.

What is a common problem with the Impco GM 3.0L engine?

A commonly reported issue on generators using the Impco GM 3.0L is: Fuel pressure issues. Cause: Inadequate supply pressure to the fuel system low pressure regulator. Fix: Check for negative pressure between -2.0” W.C. to -6.0” W.C., and ensure proper gas supply pressure.