Onan Modified Ford V-6 ESG-642 Engine Engine
The Onan Modified Ford V-6 ESG-642 is an engine. It powers generator sets from Cummins/Onan, including the xxxxxxxxxxxxxxx. It holds 6 L (1.6 gal) of oil and 7 L (1.8 gal) of coolant.
Also known as: Onan Modified Ford V-6 ESG-642
Engine specifications
| Oil capacity | 6.0 L |
|---|
| Coolant capacity | 7.0 L |
|---|
Generator sets powered by this engine
1Cummins/Onan xxxxxxxxxxxxxxx
Common problems
15- WEAK BATTERY (WARNING) CODE 1442
- UNDER FREQUENCY (SHUTDOWN) CODE 1448
- Status Indicators are not functioning properly.
Fix: Check the status indicators for any visible damage or loose connections. If the issue persists, refer to the troubleshooting table for further assistance. - SHORT CIRCUIT (SHUTDOWN) CODE 1445
- OVER FREQUENCY (warning) CODE 1449
- OVER CURRENT (WARNING/SHUTDOWN) CODE 1471/1472
- LOW COOLANT LEVEL (WARNING/SHUTDOWN) CODE 197/235
- LOW BATTERY VOLTAGE (WARNING) CODE 441
- LOW AC VOLTAGE (SHUTDOWN) CODE 1447
- Line Circuit Breaker (Optional) trips frequently.
Fix: Check the circuit breaker for any visible damage or loose connections. Verify that the load connected to the generator is within the rated capacity of the unit. If the issue persists, refer to the troubleshooting table for further assistance. - KW OVERLOAD (WARNING) CODE 1444
- HIGH BATTERY VOLTAGE (WARNING) CODE 442
- HIGH AC VOLTAGE (SHUTDOWN) CODE 1446
- Generator produces low output power. F02
Fix: Check the air filter for blockage or damage. Verify that the fuel supply is adequate and check for any fuel system issues. Refer to the Fault Code Table for further troubleshooting. - Generator produces excessive vibration. F04
Fix: Check the engine mounts for any damage or wear. Verify that all components are properly tightened, including bolts and nuts. Refer to the Fault Code Table for further troubleshooting.
Compiled from service & troubleshooting documentation across every generator set that uses the Onan Modified Ford V-6 ESG-642.
Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|
| Fuel filter | | | — | | find |
| Oil filter | | | — | | find |
| Belt | | | — | | find |
| Coolant filter | | | — | | find |
| Oil | | 6.0 Qts | — | | |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Common questions
What is the oil capacity of the Onan Modified Ford V-6 ESG-642?
The Onan Modified Ford V-6 ESG-642 engine has an oil capacity of 6.0 liters.
Which generators use the Onan Modified Ford V-6 ESG-642 engine?
The Onan Modified Ford V-6 ESG-642 powers 1 generator set(s), including Cummins/Onan xxxxxxxxxxxxxxx.
What is a common problem with the Onan Modified Ford V-6 ESG-642 engine?
A commonly reported issue on generators using the Onan Modified Ford V-6 ESG-642 is: WEAK BATTERY (WARNING).