Cummins/Onan VT1710-G Engine Engine

The Cummins/Onan VT1710-G is a 27.36 L 12-cylinder turbocharged engine rated at 1800 rpm, producing up to 511 kW. It powers generator sets from Cummins/Onan, including the DF. It holds 102.1 L (27.0 gal) of oil and 160.8 L (42.5 gal) of coolant.

Also known as: Cummins VT1710-G

Part of the Cummins/Onan VT1710 engine family — 2 variants share parts & fitment.

27.36 L
Displacement
12
Cylinders
1800 rpm
Rated speed
511 kW
Gross power

Engine specifications

Oil capacity102.1 L
Coolant capacity160.8 L
Displacement27.36 L
Cylinders12
AspirationTurbocharged
Rated speed1800 rpm
Gross power511 kW

Generator sets powered by this engine

1

Common problems

15
  • When pressing test lamp.button - one or more fault lamps do not light.
    Fix: Fault lamp/lamps burned, out - replace.
  • Voltage regulation poor
    Fix: Check continuity from the junction of Control Rectifiers 3 and 4 to the junction of Control Rectifiers 1 and 2
  • The FAULT 1 or FAULT 2 fault lamp lights. Engine shuts down immediately, engine runs for several seconds and then shuts down, or engine continues to run.
    Cause: Engine standard undesignated fault functions are programmed to shut down the set when a fault is sensed. Fault 1 is timed delayed while Fault 2 is immediate. The nature of the fault is an optional selection that is determined when the set installation is designed. The undesignated fault functions may also be programmed for non-shutdown or non-time delay.
  • The external alarm is activated
    Fix: Check the conditions that may have caused the fault
  • The engine does not start.
    Cause: The starter will disengage after a specified period of time and the control will indicate an overcrank fault.
    Fix: Place the Run-Stop-Remote switch in the STOP position and momentarily depress the Reset switch. Wait two minutes for the starter motor to cool and then repeat the starting procedure.
  • The engine does not run after a second attempt at starting.
    Fix: Refer to the Troubleshooting section.
  • SWITCH OFF lamp flashes. 8
    Fix: Position which will prevent automatic starting if an automatic transfer switch is used. Move the Run/Stop/Remote switch to the Remote position for automatic starting.
  • PRE LO OIL PRES lamp lights. Engine continues to operate. 4
    Fix: 4. Indicates engine oil pressure has dropped to 20 psi (138 kPa). If generator is powering critical loads and cannot be shut down, wait until next shutdown period and then follow step 5 procedure. If engine can be stopped, follow procedures in step 5.
  • PRE HI ENGINE TEMP lamp lights. Engine continues to operate. 2
    Fix: 2. Indicates engine has begun to overheat and engine temperature has risen to approximately 205°F (97°C). If generator is powering non-critical and critical loads and cannot be shutdown, use the following: a. Reduce load if possible by turning off non-critical loads. b. Check air inlets and outlets and remove any obstructions to airflow. c. Open doors or windows in generator area to increase ventilation. If engine can be stopped, follow procedure in step 3.
  • Partial loss of residual in Rotor from E2 to heat sink of field rectifier No. 1 until voltage begins to build-up.
    Fix: None; Then remove.
  • Overspeed shutdown.
    Fix: . Check governor and throttle linkages for freedom of movement. —°Check overspeed switch.
  • Overspeed light on, no shutdown.
    Fix: . Engine monitor board or sensor malfunction. Contact an Onan Distributor.
  • Overspeed lamp lights - no fault condition exists.
    Fix: Replace overspeed circuit board.
  • OVERCRANK lamp lights and engine stops cranking. 6
    Fix: 6. Indicates possible fuel system problem. a. Check for empty fuel tank, fuel leaks, or plugged fuel lines and correct as required. b. Check for dirty fuel filter and replace if necessary (see MAINTENANCE section). c. Check for dirty or plugged air filter and replace if necessary (see MAINTENANCE section). d. Refer to Step 5. e. Reset the control and restart after correcting the problem. Contact an Onan Dealer or Distributor for service if none of the above.
  • Overcrank fault lamp lights and engine stops cranking after approximately 75-seconds.
    Fix: 1. Check for empty fuel tank, fuel system leaks, or plugged fuel filters and/or supply lines. Correct as required.

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan VT1710-G.

Maintenance schedule

ItemSpecCapacityPart #Interval
Fuel filterChange after 30-50 hours when switching to biodiesel50 hr find
CoolantClean soft water with rust/scale inhibitor additive42.5 gallons1000 hr
OilAPI Class CC/CD max sulphated ash 1.85%27.0 gallons100 hr

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Parts cataloged across the Cummins/Onan VT1710 family

61
Part #DescriptionCategory
503-0008Belt, Alternator Drivebelt
130-0465Bracebrace
130-0466Bracebrace
110-1168Bracket & Nipple Assemblybracket_nipple
505-0207Bushing, Reducer (2-1/2 x 2")bushing_reducer
505-0270Bushing, Reducer (2 x 1-1/4")bushing_reducer
503-0011Clampclamp
503-0059Clampclamp
503-0518Clampclamp
330-0004Cover, Boxcover_box
505-0719Cross, Pipe (1")cross_pipe
504-0006Valve, Draindrain_valve
505-0453Elbow (90° )elbow_90
505-0175Elbowelbow_pipe
505-0216Elbow! Street (90°)elbow_street
130-0740Flange Assemblyflange_assembly
503-0249Hose − Bulk (Order by the Foot − 3 Feet Required)hose
503-0359Hose (1-5/8" I.D. x 3 ' )'hose
503-0365Clamp, Hosehose
503-0512Hose (2-7/8" I.D. x 18" )hose
503-0569Hose (3−1/2” ID) Bulk (Order By The Foot − 2 Feet Required)hose
505-0172Nipple, Close (2 x 2")hose
309-0243Valve, Marsh (1-1/4" )marsh_valve
307-0844Valve, Solenoidnipple
505-0173Nipple (2 x 4")nipple
505-0328Nipple ( 3 x 6 " )nipple
505-0604Nipple (3 x 9-3/4" )nipple
505-0615Nipple (3 x 24" )nipple
505-0178Nipple, Halfnipple_half
505-0380Nipple, Half (2 x 3")nipple_half
505-0437Nipple, Half (1-1/4 x 4")nipple_half
130-0687Standpipeother_service
307-0839Valve, Solenoidother_service
331-0027Clamp, Junction Box - Spec A through Gother_service
333-0138Heater, Engine (4000 Watts, 240 Volts)other_service
503-0429Screw, Self-locking (3/8-16 x 3/4“)other_service
504-0062504-005 Iother_service
505-0042Elbow (90°)other_service
505-00571 Plug (1/8") 10 ELBOW, OIL LINE TO FILTER ADAPTERother_service
505-0086Nipple (4 x 2-1/2"}, Exhaust 850-0030 2 Air Inlet Mounting (#10)other_service
505-0099Vaporizer Assembly Bracket, Vaporizer Mountingother_service
505-0258Nipple (1-1/4 x 3")other_service
505-0419Nipple (2 x 12")other_service
505-0669Teeother_service
505-0679Nipple (3 x 12" )other_service
800-0006Screw (1/4-20 x 7/8") - Not Shownother_service
800-0007Plug, Oil Drainother_service
800-00913 Poleother_service
813-0103Screw, Machine - Round Head (#10-32 x 3/4º)other_service
850-0040Base, Oilother_service
850-0060Washer, Lock - Springother_service
862-0001Stud (1/4-20x3.12)other_service
862-0005Nipple, Pipe - Close Plug, Pipe - Square Head Clampother_service
870-0053(350-0030other_service
330-0005Box, Outletoutlet_box
B184PHASE SELECTOR SWITCHphase_selector_switch
800-0092Screw, Cap - Hex Head (1/2-13 x 1.5)screw
179-0341Solenoid Valve Installationsolenoid_valve
130-0897Supportsupport
309-0253Thermostatthermostat
130-0801Nipple Assembly, Waterlinewaterline_nipple

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

What is the oil capacity of the Cummins/Onan VT1710-G?

The Cummins/Onan VT1710-G engine has an oil capacity of 102.1 liters.

What is the displacement of the Cummins/Onan VT1710-G?

The Cummins/Onan VT1710-G has a displacement of 27.36 liters with 12 cylinders.

Which generators use the Cummins/Onan VT1710-G engine?

The Cummins/Onan VT1710-G powers 1 generator set(s), including Cummins/Onan DF.

How often should you change the oil in the Cummins/Onan VT1710-G?

The Cummins/Onan VT1710-G oil change interval is every 100 hours.

What is a common problem with the Cummins/Onan VT1710-G engine?

A commonly reported issue on generators using the Cummins/Onan VT1710-G is: When pressing test lamp.button - one or more fault lamps do not light.. Fix: Fault lamp/lamps burned, out - replace..