Kubota Z482B Engine Engine
The Kubota Z482B is a 0.48 L 2-cylinder water cooled engine rated at 3600 rpm. It powers generator sets from Cummins/Onan and Kubota, including the MDKUB, Spec A AUX, DKX-AUXA and DKX-AUXA 2A. It holds 4.73 L (1.2 gal) of oil and 2.8 L (0.7 gal) of coolant.
Also known as: Kubota Z482B
Engine specifications
| Oil capacity | 4.73 L |
|---|
| Coolant capacity | 2.8 L |
|---|
| Displacement | 0.479 L |
|---|
| Cylinders | 2 |
|---|
| Aspiration | Water Cooled |
|---|
| Rated speed | 3600 rpm |
|---|
Generator sets powered by this engine
4Shared across brands: Cummins/Onan, Kubota
Common problems
15- Weakness and Sleepiness
Fix: Get out into the fresh air immediately. If symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired. - Vomiting
Fix: Get out into the fresh air immediately. If symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired. - Muscular Twitching
Fix: Get out into the fresh air immediately. If symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired. - Low Oil Pressure
Cause: Oil level is low.
Fix: Add oil to bring the level up to full mark. Inspect engine exterior for leaks and repair as necessary. - Inability to Think Coherently
Fix: Get out into the fresh air immediately. If symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired. - High Exhaust Temperature
Fix: The high exhaust temperature switch closes on temperature rise above 230° F (110° C). It closes to shut down the set if raw water flow is lost. It opens again when the temperature reaches about 190° F (88° C). - High Coolant Temperature
Fix: Check coolant level in the exhaust manifold after allowing the engine to cool down. Ensure pump belt is OK and has proper tension. The raw water flow at the exhaust outlet should be about 3 gal./min. (11.4 liter/min.). Also check cooling system cleanliness. - Dizziness
Fix: Get out into the fresh air immediately. If symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired. - Weak battery(ies)
Cause: Low electrolyte level in batteries, Long periods of non-use, Load connected to battery while unit is turned off
Fix: Replenish electrolyte and recharge battery, Use AUX to charge batteries, Disconnect load and recharge batteries - Service Access M1993s
- Power Unit Does Not Stop when Switch Is Pushed To Stop
Cause: Open circuit between control assembly (A1) and the sleeper control, Defective start/stop switch, Defective control assembly (A1)
Fix: Check wiring continuity between control assembly (A1) and sleeper control, Check the start/stop switch, Replace control assembly (A1) - Power unit alternator not functioning due to: Poor battery or alt. connections, Loose or defective belt, Defective alternator
Fix: Check connections between alternator, start solenoid and batteries, Check belt condition and tension, Refer to alternator check - No Sleeper Heat
Cause: Low coolant level, Air inlet to sleeper heater is blocked, Blocked or restricted coolant hose, Sleeper fan does not operate due to: Open circuit to sleeper fan, Defective fan speed switch, Defective or binding fan motor, Check valve defective or backwards, Solenoid valve(s) not operating due to: Open circuit to solenoid valve(s), Defective solenoid valve(s), Temp control pot on sleeper control panel defective
Fix: Check coolant level, Check for blockage of air inlet, Examine hoses for restrictions, Check wiring continuity between the fan and the sleeper control, Test fan speed switch, Check fan wheel for binding and test, Test high speed relay, Examine and test check valve, Test the solenoid valve(s), Test the temp control pot - Inoperative Run Lamp or Time Meter does not operate
Cause: Open circuit in control wiring, If hour meter works and run lamp control and control assembly (A1) do not work, Start/stop switch is defective, Control assembly (A1) is defective
Fix: Check continuity between sleeper control and run lamp, Replace start/stop switch, Replace control assembly (A1) - Hot All The Time (Too Hot)
Cause: Solenoid valve(s) defective (sticking), Temp control pot on sleeper control panel defective, Constant temp. control defective
Fix: Test the solenoid valve(s), Test the temp control pot, Replace the constant temp. control
Compiled from service & troubleshooting documentation across every generator set that uses the Kubota Z482B.
Maintenance schedule
| Item | Spec | Capacity | Part # | Interval | |
|---|
| Air filter | Air Filter | | 1522211223 | 720 hr | PartsGeek |
| Fuel filter | Fuel System | | 1627143560 | 3600 hr | PartsGeek |
| Oil filter | Oil Filter | | 7665025430 | 1800 hr | PartsGeek $7.98 |
| Belt | Drive Belts | | — | 3600 hr | find |
| Coolant | | | — | | |
| Coolant filter | Cooling System | | — | 1800 hr | find |
| Oil | Change the oil and filter at the intervals listed in the Maintenance Schedule. Use oil that meets the API classification and SAE viscosity grade indicated in the Pre-Start section. | 5.0 quarts (4.7 liters) | — | | |
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Aftermarket parts that fit this engine
45Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.
Filters for this engine
- Air filter: Kubota 1522211223 Donaldson P102745 Wix 46270 Ac Delco A527C
- Fuel filter: Kubota 1627143560 Donaldson P502166 Wix 33263
- Oil filter: Kubota 7665025430 Donaldson P550162 Wix 51334 Ac Delco X45
Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.
Also used in
4- Hitachi 08 — Construction Equipment
- Hitachi EX8 — Excavator Compact
- Hitachi EX8-2 — Excavator Compact
- Hitachi EX8-2B — Excavator Compact
Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.
Common questions
What is the oil capacity of the Kubota Z482B?
The Kubota Z482B engine has an oil capacity of 4.73 liters.
What is the displacement of the Kubota Z482B?
The Kubota Z482B has a displacement of 0.479 liters with 2 cylinders.
Which generators use the Kubota Z482B engine?
The Kubota Z482B powers 4 generator set(s), including Cummins/Onan MDKUB, Cummins/Onan Spec A AUX, Kubota DKX-AUXA, Kubota DKX-AUXA 2A.
What oil filter does the Kubota Z482B use?
The Kubota Z482B uses oil filter part numbers Kubota 7665025430, Donaldson P550162, Wix 51334.
What fuel filter does the Kubota Z482B use?
The Kubota Z482B uses fuel filter part numbers Kubota 1627143560, Donaldson P502166, Wix 33263.
What air filter does the Kubota Z482B use?
The Kubota Z482B uses air filter part numbers Kubota 1522211223, Donaldson P102745, Wix 46270.
What is a common problem with the Kubota Z482B engine?
A commonly reported issue on generators using the Kubota Z482B is: Weakness and Sleepiness. Fix: Get out into the fresh air immediately. If symptoms persist, seek medical attention. Shut down the unit and do not operate until it has been inspected and repaired..