Cummins/Onan Marquis Gold Engine Engine
The Cummins/Onan Marquis Gold is an engine rated at 2400 rpm. It powers generator sets from Cummins/Onan, including the Marquis Gold 5500 and Marquis Gold 7000.
Also known as: Onan Marquis Gold
Generator sets powered by this engine
2Cummins/Onan Marquis Gold 5500Cummins/Onan Marquis Gold 7000
Common problems
8- UNIT STARTS AND RUNS, THEN STOPS WHEN THE START SWITCH IS RELEASED
Cause: 1. Low fluid levels.
Fix: Check & bring all fluids up to the appropriate levels. - UNIT RUNS THEN SURGES
Cause: 1. Loose or worn spark plug leads. 2. Defective ignition coil, wiring, or control components. 3. Faulty spark plug. 4. Governor out of adjustment. 5. Combustion air pre-heat malfunction. 6. Carburetor icing. 7. Carburetor varnishing.
Fix: 1. Check spark plug leads at spark plug & ignition coil. 2. Contact an Onan Authorized RV Service & Parts Dealer. 3. Remove spark plug & clean or replace. 4. Contact an Onan Authorized RV Service & Parts Dealer. 5. Contact an Onan Authorized RV Service & Parts Dealer. 6. Move carburetor pre-heater to the winter position. 7. Try fuel system cleaner and contact dealer if no change. - UNIT RUNS THEN STOPS, OR STOPS WHEN DRIVING AROUND A CORNER
Cause: 1. Low fuel level. 2. Low oil level. 3. Excess oil.
Fix: 1. Add fuel. 2. Add oil. 3. Reduce engine oil level. - FAILS TO CRANK
Cause: 1. Low battery. 2. Bad battery connection. 3. Blown fuse.
Fix: 1. Check battery fluid level. 2. Clean & tighten all battery & cable connections. 3. Replace fuse on control panel. - EXHAUSTING BLACK SMOKE
Cause: 1. Dirty air filter.
Fix: Replace air filter. - CRANKS SLOWLY
Cause: 1. Low battery. 2. Bad battery connection. 3. Incorrect oil viscosity. 4. Load connected.
Fix: 1. Check battery fluid level. 2. Clean & tighten all battery & cable connections. 3. Replace with recommended viscosity oil. 4. Disconnect load before starting. - CRANKS BUT WON’T START
Cause: 1. Fuel below generator pickup level in tank. 2. Fuel supply shutoff valve closed. 3. Carbon deposits on spark plug(s). 4. Low oil level.
Fix: 1. Add fuel. 2. Fully open fuel supply valve. 3. Remove spark plug(s) and replace. 4. Add oil. - CIRCUIT BREAKER TRIPS
Cause: 1. Overloaded circuit.
Fix: Turn-off some of the electrical load, and reset the circuit breaker.
Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan Marquis Gold.
Common questions
Which generators use the Cummins/Onan Marquis Gold engine?
The Cummins/Onan Marquis Gold powers 2 generator set(s), including Cummins/Onan Marquis Gold 5500, Cummins/Onan Marquis Gold 7000.
What is a common problem with the Cummins/Onan Marquis Gold engine?
A commonly reported issue on generators using the Cummins/Onan Marquis Gold is: UNIT STARTS AND RUNS, THEN STOPS WHEN THE START SWITCH IS RELEASED. Cause: 1. Low fluid levels.. Fix: Check & bring all fluids up to the appropriate levels..