Yanmar 4TNE98-ACG Engine Engine
The Yanmar 4TNE98-ACG is a 0 L natural engine rated at 1800 rpm. It powers generator sets from Atlas Copco, including the QAS 38. It holds 9.46 L (2.5 gal) of oil and 6.1 L (1.6 gal) of coolant.
Also known as: Yanmar 4TNE98-ACG
Part of the Yanmar 4TNE98 engine family — 2 variants share parts & fitment.
Engine specifications
| Oil capacity | 9.46352778 L |
|---|
| Coolant capacity | 6.096 L |
|---|
| Displacement | 0.0033 L |
|---|
| Aspiration | Natural |
|---|
| Rated speed | 1800 rpm |
|---|
Generator sets powered by this engine
1
Common problems
15- Unstable voltage
Cause: - Speed variation in engine.
Fix: Check regularity of rotation. - The starter motor turns the engine too slowly
Cause: - Battery capacity too low. - Bad electrical connection. - Fault in starter motor. - Wrong grade of lubricating oil. - The engine does not start or is difficult to start
Cause: - Starter motor turns engine too slowly. - Fuel tank empty. - Fault in fuel control solenoid. - Restriction in a fuel pipe. - Fault in fuel lift pump. - Dirty fuel filter element. - Air in fuel system. - Fault in atomisers. - Cold start system used incorrectly. - Fault in cold start system. - Restriction in fuel tank vent. - Wrong type or grade of fuel used. - Restriction in exhaust pipe. - Rotating bridge failure
Cause: - Check diodes, disconnect cables. - Regulator out of setting
Fix: Regulate stability of regulator by acting on “STABILITY” potentiometer. - Not enough power
Cause: - Restriction in a fuel pipe. - Fault in fuel lift pump. - Dirty fuel filter element. - Restriction in air filter/cleaner or induction system. - Air in fuel system. - No residual voltage
Fix: For an instant apply on the + and – terminals of the electronic regulator a 12 V battery voltage with a 30 Ω resistor in series respecting the polarities. - Lower than rated voltage at load
Cause: - Voltage potentiometer out of setting.
Fix: Reset voltage potentiometer. - Low voltage at no load
Cause: - Voltage potentiometer out of setting.
Fix: Reset voltage. - Loose sensing wires on AVR
Fix: Check sensing wires on AVR. - Insufficient residual voltage
Fix: Increase the speed by 15 %. - Higher than rated voltage at load
Cause: - Voltage potentiometer out of setting.
Fix: Reset voltage potentiometer. - High voltage at no load
Cause: - Voltage potentiometer out of setting.
Fix: Reset voltage potentiometer. - Failed regulator
Fix: Substitute regulator. - Current too high, power factor lower than 0.8; speed lower than 10 % of rated speed
Cause: - Failed regulator.
Fix: Substitute regulator.
Compiled from service & troubleshooting documentation across every generator set that uses the Yanmar 4TNE98-ACG.
Parts cataloged across the Yanmar 4TNE98 family
1| Part # | Description | Category |
|---|
| 244H | machine | other_service |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
Aftermarket parts that fit this engine
60Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.
Also used in
9- Gehl CTL60 — Loader Tracked
- John Deere 244H — Loader Wheeled
- John Deere 304H — Loader
- John Deere 80 — Excavator
- Komatsu PW85 — Excavator Wheeled
- Neuson 6002 — Combine
- Neuson 8002HV — Combine
- Neuson 8002RD — Combine
- Sumitomo SH75X-3 — Excavator
Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.
Common questions
What is the oil capacity of the Yanmar 4TNE98-ACG?
The Yanmar 4TNE98-ACG engine has an oil capacity of 9.46352778 liters.
What is the displacement of the Yanmar 4TNE98-ACG?
The Yanmar 4TNE98-ACG has a displacement of 0.0033 liters.
Which generators use the Yanmar 4TNE98-ACG engine?
The Yanmar 4TNE98-ACG powers 1 generator set(s), including Atlas Copco QAS 38.
What is a common problem with the Yanmar 4TNE98-ACG engine?
A commonly reported issue on generators using the Yanmar 4TNE98-ACG is: Unstable voltage. Cause: - Speed variation in engine.. Fix: Check regularity of rotation..