HomeEnginesIsuzu 4LE1NYGV-03 or 4LE1NYGV-03E

Isuzu 4LE1NYGV-03 or 4LE1NYGV-03E Engine Engine

The Isuzu 4LE1NYGV-03 or 4LE1NYGV-03E is an engine. It powers generator sets from Magnum, including the MLT5200IV.

Also known as: Isuzu 4LE1NYGV-03 or 4LE1NYGV-03E

Engine specifications

Generator sets powered by this engine

1
Magnum MLT5200IV

Common problems

6
  • Mast lights on but the light output is low
    Fix: 1. Fixture or lens are dirty. Clean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass. 2. Bulb worn due to normal use. Replace bulb. 3. Check the mast coil cord, mast junction box and mast light connections. 4. Generator output incorrect. Check the incoming voltage to the ballast. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, engine speed may need to be adjusted or generator may require service. 5. Low transformer output. The voltage from the transformer should read approximately 400 VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240-260 VAC. On quick disconnect models, measure across the junction box terminals when the light is unplugged. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.
  • Mast lights off but ballast indicators on control panel are on
    Fix: 1. Mast light is too hot. Allow light to cool 10-15 minutes before restarting. 2. Faulty bulb connection. Check that the bulb is tight in the socket. 3. Bulb broken. Check for broken arc tube or outer bulb jacket, broken or loose components in bulb envelope or blackening/deposits inside tube. 4. Check the connections inside the mast junction box and each mast light housing/socket. 5. Check the mast electrical cord for damage and check the cord connections inside the control box.
  • Mast lights off and ballast indicators on control panel are off
    Fix: 1. Check the connections inside the control box and inside each ballast box. 2. Generator output incorrect. Check the incoming voltage to the ballast by checking the available voltage on the duplex receptacle. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, the engine speed may need to be adjusted or generator may require service. 3. Low transformer output. The voltage from the transformer should read approximately 400 VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240-260 VAC. On quick disconnect models, measure across the junction box terminals when the light is unplugged. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced.
  • Mast light is too hot
    Fix: Allow light to cool 10-15 minutes before restarting.
  • Faulty bulb connection
    Fix: Check that the bulb is tight in the socket.
  • Bulb broken
    Fix: Check for broken arc tube or outer bulb jacket, broken or loose components in bulb envelope or blackening/deposits inside tube.

Compiled from service & troubleshooting documentation across every generator set that uses the Isuzu 4LE1NYGV-03 or 4LE1NYGV-03E.

Also used in

4
  • Hitachi EX40U — Excavator Compact
  • Hitachi EX50U — Excavator Compact
  • Hitachi EX55UR-3 — Excavator Compact
  • Hitachi EX58MU — Excavator Compact

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

Which generators use the Isuzu 4LE1NYGV-03 or 4LE1NYGV-03E engine?

The Isuzu 4LE1NYGV-03 or 4LE1NYGV-03E powers 1 generator set(s), including Magnum MLT5200IV.

What is a common problem with the Isuzu 4LE1NYGV-03 or 4LE1NYGV-03E engine?

A commonly reported issue on generators using the Isuzu 4LE1NYGV-03 or 4LE1NYGV-03E is: Mast lights on but the light output is low. Fix: 1. Fixture or lens are dirty. Clean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass. 2. Bulb worn due to normal use. Replace bulb. 3. Check the mast coil cord, mast junction box and mast light connections. 4. Generator output incorrect. Check the incoming voltage to the ballast. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, engine speed may need to be adjusted or generator may require service. 5. Low transformer output. The voltage from the transformer should read approximately 400 VAC as the light “strikes” (induces an arc), then drop and slowly rise back up to stabilize at 240-260 VAC. On quick disconnect models, measure across the junction box terminals when the light is unplugged. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced..