HomeEnginesHonda GX670

Honda GX670 Engine Engine

The Honda GX670 is a 0.67 L 2-cylinder 4 stroke, oh valve engine rated at 3600 rpm. It powers generator sets from Cummins/Onan, including the GRCA. It holds 1.48 L (0.4 gal) of oil.

Also known as: Honda GX670

0.67 L
Displacement
2
Cylinders
3600 rpm
Rated speed
1.48 L
Oil capacity

Engine specifications

Oil capacity1.48 L
Displacement0.67 L
Cylinders2
Aspiration4 Stroke, OH Valve
Rated speed3600 rpm

Generator sets powered by this engine

1
Cummins/Onan GRCA

Troubleshooting

2

Symptoms & remedies

SymptomCauseRemedy
Engine will not startFUSE REP
Engine lacks powerFrequent fuse failure usually indicates a short circuit or an overload in the electrical system.Take the engine to an authorized Honda servicing dealer for repair.

Fault codes and symptom→remedy steps extracted from this engine’s service/owner documentation; verify against the official manual before servicing.

Common problems

11
  • STARTING BATTERIES RUN DOWN (Marginal batteries, connections, or charging system or parasitic loads)
    Fix: 1. Clean and tighten the positive (+) and negative (–) genset battery cable connections. 2. Recharge or replace the battery. Refer to the battery manufacturer's recommendations. 3. Have a battery charging system installed or serviced.
  • STarter ENGAGES–DISENGAGES (Cranking voltage dips below 6 volts—low battery charge, poor connections, long cables)
    Fix: 1. Clean and tighten the positive (+) and negative (-) genset battery cable connections. 2. Recharge or replace the battery. Refer to the battery manufacturer's recommendations.
  • SERVICE CHECK FAULT—CODE NO. 3 3
    Fix: 1. Reduce the number of appliances running at the same time, especially those with high motor starting loads such as air conditioners. 2. Open any closed fuel valves and check for an adequate fuel supply. 3. Check for fouled spark plugs. 4. Check air cleaner. 5. Clean and tighten the positive (+) and negative (-) genset battery cable connections. 6. If the condition still exists, contact Cummins/Onan Service.
  • OVERCRANK FAULT—CODE NO. 4 4
    Fix: 1. Check fuel level. 2. Open any closed fuel valves. 3. Secure the spark plug lead on the spark plug. 4. Check the spark plugs. 5. Service the air cleaner.
  • NO POWER—GENSET RUNNING, RUN LIGHT ON (Line circuit breaker OFF or tripped or faulty wiring)
    Fix: 1. Turn on or reset the line circuit breaker on the genset. 2. Turn on or reset the line circuit breakers on the main distribution panel 3. If the condition still exists, contact Cummins/Onan service.
  • LOW OIL PRESSURE FAULT—CODE NO. 2 2
    Cause: The controller sensed that the low oil pressure cutoff did not open within 10 seconds of starting
    Fix: 1. Check engine oil level and add oil as necessary. Repair oil leaks. 2. Drain excess oil. (Excess oil leads to foaming and a consequent loss of oil pressure.) 3. If the oil level is OK, contact Cummins/Onan Service.
  • Fuel or exhaust leak
    Fix: Stop the genset immediately and have it repaired before continuing operation.
  • Engine does not start after 20 seconds of cranking
    Fix: See Troubleshooting in Section 11 if the engine does not start.
  • Engine does not start
    Fix: See Troubleshooting in Section 4
  • Electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive.
    Fix: (1) Wear full eye protection and protective clothing, (2) Where electrolyte contacts the skin, wash it off immediately with water and seek medical attention, (3) Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention, (4) Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of one pound (500 grams) bicarbonate of soda to one gallon
  • Code No. 4: blink-blink-blink-blink Code No. 4

Compiled from service & troubleshooting documentation across every generator set that uses the Honda GX670.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filter find
Fuel filter find
Oil filter find
Belt find
Coolant
Coolant filter find
Oil

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Aftermarket parts that fit this engine

38
31630-ZJ1-802 PartsGeek FridayParts $48.50 GX610 PartsGeek GX620 PartsGeek GX670 PartsGeek GXV610 PartsGeek GXV620 PartsGeek 30500-ZJ1-845 PartsGeek FridayParts $32.99 30550-ZJ1-845 PartsGeek FridayParts $32.99 30500-ZJ1-844 PartsGeek FridayParts $32.99 14100-ZJ1-842 PartsGeek FridayParts $145.80 12209-ZE8-003 PartsGeek GX240 PartsGeek GX270 PartsGeek GX340 PartsGeek GX390 PartsGeek GXV270 PartsGeek GXV340 PartsGeek 17218-ZJ1-840 PartsGeek 31740-ZJ1-003 PartsGeek GXV670 PartsGeek 16910-ZE8-015 PartsGeek GXV390 PartsGeek EB11000 PartsGeek 16700-Z0J-003 PartsGeek FridayParts $29.99 16700-ZL8-013 PartsGeek FridayParts $29.99 16700-Z8A-004 PartsGeek FridayParts $29.99 1028279-01 PartsGeek FridayParts $19.99 785634 PartsGeek FridayParts $19.99 GX630 PartsGeek GX660 PartsGeek GX690 PartsGeek 228000-7850 PartsGeek FridayParts $115.85 31200-ZJ1-841 PartsGeek FridayParts $115.85 GX610K1 PartsGeek BW90 PartsGeek BW900 PartsGeek FP-XP-0019437 PartsGeek FP-XP-0042511 PartsGeek

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Common questions

What is the oil capacity of the Honda GX670?

The Honda GX670 engine has an oil capacity of 1.48 liters.

What is the displacement of the Honda GX670?

The Honda GX670 has a displacement of 0.67 liters with 2 cylinders.

Which generators use the Honda GX670 engine?

The Honda GX670 powers 1 generator set(s), including Cummins/Onan GRCA.

What is a common problem with the Honda GX670 engine?

A commonly reported issue on generators using the Honda GX670 is: STARTING BATTERIES RUN DOWN (Marginal batteries, connections, or charging system or parasitic loads). Fix: 1. Clean and tighten the positive (+) and negative (–) genset battery cable connections. 2. Recharge or replace the battery. Refer to the battery manufacturer's recommendations. 3. Have a battery charging system installed or serviced..