Home›Engines›4.3L V-6

4.3L V-6 Engine

The 4.3L V-6 is a 2.62 L engine. It powers generator sets from General Motors, including the 4.3L. It holds 5 L (1.3 gal) of oil and 8 L (2.1 gal) of coolant.

Also known as: 4.3L V-6

Part of the 4.3L engine family — 2 variants share parts & fitment.

2.62 L
Displacement
5.0 L
Oil capacity

Engine specifications

Oil capacity5.0 L
Coolant capacity8.0 L
Displacement2.62 L

Generator sets powered by this engine

1

Common problems

15
  • UNIT NOT IN AUTO LED
    Fix: 7. Indicates AUTO/OFF/MANUAL switch is in the OFF position which will prevent automatic starting if an automatic transfer switch is used. Move the AUTO/OFF/MANUAL switch to the AUTO position for automatic starting.
  • Low Fuel LED 11
    Fix: Check fuel supply and replenish as required.
  • UNIT WILL START THEN FAIL High Water Temperature light lit
    Fix: Low water level in radiator. Thermostat closed. Broken fan belt. Restricted flow through radiator. Ambient temperature too high. Defective temperature switch.
  • Unit Running but Starter does not disengage
    Fix: Starter drive could be hanging up or the solenoid on starter is not disengaging.
  • UNIT KS Voltage on Terminal #2 while Unit does not start.
    Fix: Check for voltage source. There should be no voltage present.
  • Terminal #5 Unused Terminal not connected to KASSEC Terminal #9, ground.
    Fix: Connect Terminal #5 when in use or it may prevent unit from starting.
  • Press To Test Button 13
  • PRE-HI ENGINE TEMP LED. Engine continues to operate
    Fix: 1. Indicates engine has begun to overheat and engine temperature has risen approximately 215°F (105°C). If generator is powering non-critical and critical loads and cannot be shut down. a. Reduce load if possible by turning off non-critical loads. b. Check air inlets and outlets and remove any obstructions to airflow. c. Open doors or windows in generator area to increase ventilation. 2. If engine can be stopped, follow procedure i in Step 2.
  • PRE LOW OIL PRESSURE LED. Engine continues to operate
    Fix: 3. Indicates engine oil pressure has dropped to 20 psi (138kPa). If generator is powering critical loads and cannot be shut down, wait until next shutdown period and then follow Step 4 procedure. If engine can be stopped, follow procedures in Step 4.
  • Overspeed light lit
    Fix: Lost governor control. Defective overspeed switch.
  • Overcrank light-lit
    Fix: Lost signal on Mag Pickup Crank Disconnect Terminal or lost signal on Auxiliary Crank Disconnect terminal after unit started.
  • OVERCRANK LED. Engine stops cranking
    Fix: A. Check for empty fuel tank, fuel leaks, or plugged fuel lines and correct as required. b. Check for dirty fuel filter and replace if necessary (See Maintenance section of Engine Manual). c. Check for dirty or plugged air filter and replace if necessary (See Maintenance section of Engine Manual). d. Refer to Step 4. e. Reset the control and restart after correcting the problem. Contact your Dealer or Distributor for service if none of the above.
  • Overcrank LED 17
    Fix: Check for empty fuel tank, fuel leaks, or plugged fuel lines and correct as required. Check for dirty fuel filter and replace if necessary (See Maintenance section of Engine Manual). Check for dirty or plugged air filter and replace if necessary (See Maintenance section of Engine Manual).
  • No Engine Stop. 29
    Fix: Check Engine Start Timer setting. Check Engine Start Connections. Investigate why the Engine Control Switch was put in Manual. Contact your Dealer or Distributor for assistance.
  • No Engine Start. 28
    Fix: Check Engine Start connections. Investigate why the Engine Control Switch was put in Manual. Contact your Dealer or Distributor for assistance.

Compiled from service & troubleshooting documentation across every generator set that uses the 4.3L V-6.

Parts cataloged across the 4.3L family

35
Part #DescriptionCategory
1.062Belt Idler Pulley (Grooved)Belt
374176Drive BeltBelt
188045Exhaust Manifold GasketGasket
188048Oil Filter Adapter Seal (O-ring)Oil filter
188050Oil Filter Adapter GasketOil filter
188052Oil FilterOil filter
0.096Crankshaft Bearing KitService part / kit
0.303Valve SpringService part / kit
0.308Valve Stem Oil SealsService part / kit
0.309Valve Spring CapService part / kit
0.310Valve Stem KeyService part / kit
0.333Valve Rocker Arm AssemblyService part / kit
0.386Valve Rocker Arm CoverService part / kit
0.423Valve Rocker Arm Cover Bolt GrommetService part / kit
0.426Valve PushrodService part / kit
0.429Valve Rocker Arm SupportService part / kit
0.439Valve Lifter Pushrod GuideService part / kit
0.459Valve LifterService part / kit
0.529Balance Shaft Gear Kit (Includes Drive and Driven Gears)Service part / kit
0.539Camshaft BearingService part / kit
0.603Connecting RodService part / kit
0.616Connecting Rod Bearing KitService part / kit
0.649Clutch Pilot BearingService part / kit
0.659Balance ShaftService part / kit
0.662Crankshaft Balancer KeyService part / kit
0.724Camshaft Timing ChainService part / kit
0.736Camshaft SprocketService part / kit
1-6-5-4-3-2Firing OrderService part / kit
1.219Coolant RadiatorService part / kit
3.454Accelerator Control Cable BracketService part / kit
328540Clutch Pilot Bearing Remover J 43276-2 Forcing ScrewService part / kit
353275Clutch Pilot Bearing Remover J 43276Service part / kit
64126Clutch Pilot Bearing Remover J 43276-1 Tool BodyService part / kit
0.137Crankshaft Rear Oil SealSeal
0.213Crankshaft Front Oil SealSeal

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

What is the oil capacity of the 4.3L V-6?

The 4.3L V-6 engine has an oil capacity of 5.0 liters.

What is the displacement of the 4.3L V-6?

The 4.3L V-6 has a displacement of 2.62 liters.

Which generators use the 4.3L V-6 engine?

The 4.3L V-6 powers 1 generator set(s), including General Motors 4.3L.

What is a common problem with the 4.3L V-6 engine?

A commonly reported issue on generators using the 4.3L V-6 is: UNIT NOT IN AUTO LED. Fix: 7. Indicates AUTO/OFF/MANUAL switch is in the OFF position which will prevent automatic starting if an automatic transfer switch is used. Move the AUTO/OFF/MANUAL switch to the AUTO position for automatic starting..