Home›Engines›Kubota Z482

Kubota Z482 Engine

The Kubota Z482 is a 0.48 L 2-cylinder naturally aspirated engine rated at 3000 rpm, producing up to 9.32 kW. It powers generator sets from Cummins/Onan, Denyo, FG Wilson, Fischer Panda, Generac, Kubota, MQ Power, Paguro and WhisperPower, including the MDKB, DA-6000SS, KH6-1S and 8000i PMS. It holds 3.8 L (1.0 gal) of oil and 3.8 L (1.0 gal) of coolant.

Also known as: Kubota® Z482, Z482

Part of the Kubota Z482 engine family — 4 variants share parts & fitment.

0.479 L
Displacement
2
Cylinders
3000 rpm
Rated speed
9 kW
Gross power

Service parts for the Z482

The cheapest captured merchant offer per filter — see the full cross-reference below for every OEM/aftermarket option.

Air intake

1 required

Fuel system

1 required
1522143081Fuel filter$37.58eBay

Prices captured from merchant listings; some links are affiliate links. Verify against your serial number before ordering.

Engine specifications

Oil capacity3.8 L
Coolant capacity3.8 L
Displacement0.479 L
Cylinders2
Aspirationnaturally aspirated
Rated speed3000 rpm
Gross power9 kW

Common problems

15
  • Use or operate the engine on or near any forest-covered, brush-covered land, or grass-covered land.
    Fix: The exhaust system must be equipped with a working spark arrester meeting state laws.
  • Touch the terminals and sockets while the machine is running.
    Fix: Avoid electric shock hazard: Do not touch the terminals and sockets while the machine is running.
  • Touch the machine with wet hands.
    Fix: Avoid electric shock hazard: Do not touch the machine with wet hands.
  • Check and service the machine while it is running.
    Fix: Avoid electric shock and injury hazard: Do not check and service the machine while it is running.
  • Battery fluid level stands below the LOWER mark.
    Fix: Immediately, add distilled water until the fluid level is between the UPPER and LOWER levels. (for only refillable battery)
  • Use machine in poorly-ventilated place
    Fix: To avoid exhaust gas poisoning hazard, do not use the machine indoors or in tunnels.
  • Touch terminals and sockets while running
    Fix: To avoid electric shock hazard, do not touch the terminals and sockets while the machine is running.
  • Touch machine with wet hands
    Fix: To avoid electric shock, do not touch the machine with wet hands.
  • Generator does not start or runs poorly.
    Cause: Faulty spark plug, dirty air filter, clogged fuel line, low fuel level, faulty ignition system, or incorrect engine oil level.
    Fix: Check and replace the spark plug if necessary. Clean or replace the air filter. Clear any blockages in the fuel line. Refuel with fresh fuel. Check and adjust the ignition system as needed. Ensure the correct amount of engine oil is present.
  • Direct exhaust to people and buildings
    Fix: To avoid exhaust gas poisoning and fire hazard, do not direct the exhaust to people and buildings.
  • Check and service machine while running
    Fix: To avoid electric shock and injury hazard, do not check and service the machine while it is running.
  • Battery fluid level below LOWER mark
    Fix: To avoid component deterioration and potential explosion, add distilled water until the fluid level is between UPPER and LOWER marks.
  • UNDERVOLTAGE 13
    Fix: Reduce the number of connected appliances, especially when air conditioners and battery chargers are running.
  • UNDERFREQUENCY—Engine governor unable to maintain rated frequency CODE NO. 15
    Fix: 1. Reduce the number of appliances running at the same time, especially those with high motor starting loads such as air conditioners. 2. Check the fuel tank and fill as necessary. (Note: The arrangement of pickup tubes in the fuel supply tank probably is such that the genset will run out of fuel before the propulsion engines.) 3. Remove any blockage in the combustion air inlet (front grille) or exhaust system. 4. Tighten loose fuel line fittings so that air cannot be drawn in by genset lift pump suction. 5. Drain and/or replace the fuel filter (Page 16) and prime the fuel system (Page 8). 6. Drain and/or replace fuel supply system filters and prime the fuel system (Page 8).
  • Underfrequency 15
    Fix: Check engine speed, loads, governor actuator operation, fuel supply, control plugs fully seated, quad leads fully seated in connector to control, quad winding resistance

Compiled from service & troubleshooting documentation across every generator set that uses the Kubota Z482.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterCleaning Secondary Air Filter Element, Cleaning Primary Air Filter ElementG3102-8839-0200 hr Amazon eBay
Fuel filter149-210650 hr Amazon eBay $34.99 NAPA $61.61 KuduParts $68.00
Oil filter122-081050 hr Amazon eBay $12.39 NAPA $3.59
Battery12V x 27Ah/5Hr44B19R50 hr eBay
Belt511-0197100 hr Amazon eBay
Coolant50.0 liter—3650 hr
Coolant filterChanging Coolant, Remedies for Rapid Coolant LossG3102-8831-0200 hr Amazon eBay
OilChecking Oil Level and Adding Engine Oil, Changing Engine Oil, Replacing the Oil Filter Cartridge50.0 %—200 hr
Spark plugReplace as needed based on operating conditionsG3102-8836-0 Amazon eBay

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Service intervals

40
ItemActionHoursMonthsNotes
Check Engine Oil LevelCheck8 hr
Drain Water from Fuel FilterDrain8 hr
Engine oil levelCheck8 hrEvery Day/8 Hrs (Table 4-1)
Exhaust systemInspect8 hrLook over entire exhaust system and listen for leaks every startup and after every eight hours of operation
Fuel FilterDrain8 hr
Fuel Filter WaterDrain8 hr
General InspectionCheck8 hrDaily, 8-Hr; includes Oil Level, Coolant Level, Fuel System, Exhaust System, Battery, and Sea Water Strainer Checks.
General InspectionInspect8 hrIncludes inspection of oil level, coolant level, fuel system, exhaust system, batteries and battery connections; before first start of day and after every 8 hours
General Inspection (Oil Level, Coolant Level, Fuel System, Exhaust System, Battery, Sea Water Strainer)Check8 hrEvery day, all models (MDKBH, MDKBJ, MDKBW, MDKB & MDKD, MDDCX)
General Inspection (oil, coolant, fuel, exhaust, batteries)Inspect8 hrevery day / before first start of the day
Generator setInspect8 hrGeneral Inspection before first start of the day and after every 8 hours of operation; includes oil level, coolant level, fuel system, exhaust system, batteries and battery connections
Change Engine Oil and Oil Filter - All except MDKBT & MDKBUChange50 hrFirst service — after first 50 hrs, then every 200 hrs/year
Change Engine Oil and Oil Filter - Only MDKBT & MDKBUChange50 hrFirst service — after first 50 hrs, then every 200 hrs/year
Engine Oil and Oil Filter (All except MDKBT & MDKBU) - after first 50 hoursChange50 hrFirst service — Break-in oil change; also change the oil and oil filter after the first 50 hours of operation on a new or re-built engine.
Engine Oil and Oil Filter (Only MDKBT & MDKBU) - after first 50 hoursChange50 hrFirst service
Engine oil and oil filter - all except MDKBT & MDKBUChange50 hrFirst service — After first 50 hours of operation; then per Table 4-1
Engine oil and oil filter - only MDKBT & MDKBUChange50 hrFirst service — After first 50 hours of operation; then per Table 4-1
Fuel line (fuel hose and clamp bands)Check50 hrEvery 50 hours
Fuel pipes and clamp bandsCheck50 hrFirst service — Replace fuel pipes and clamp bands every 2 years or earlier
Oil filter cartridgeChange200 hrFirst service — Initial 50 hours
Air cleaner elementClean100 hrFirst service — Every 100 hours
BatteryCheck100 hr1 moFirst service — See battery manufacturer's recommendations
Battery and Battery ConnectionsInspect100 hr1 moSee battery manufacturer's recommendations.
Battery electrolyteCheck100 hr
Check V-Belt TensionCheck100 hrcheck for slippage, cracking and wear
Engine Oil and Oil Filter (All except MDKBT & MDKBU)Change100 hr1 moFirst service — Perform twice as often when using high sulfur fuel.
Engine oilChange150 hrFirst service — thereafter
Fan beltCheck100 hrDamage, wear and tension
Fuel FiltersDrain100 hr1 moEvery Month / 100 Hrs
Fuel filterClean100 hrClean every 100 hours of operation
Fuel filter elementClean100 hrEvery 100 hours
Fuel filter potClean100 hr
Inspect Battery and Battery ConnectionsInspect100 hrmonthly
Siphon BreakCheck500 hr12 moMonthly, 100-Hr
Siphon BreakInspect100 hr1 moEvery Month / 100 Hrs
Water from Fuel FilterDrain100 hr1 moEvery Month/100 Hrs
Water in FuelDrain100 hrEvery Month/100 Hrs; drain more often if fuel quality is poor or condensation cannot be avoided
Water in Fuel FilterDrain100 hrEvery Month / 100 Hrs
Zinc AnodeInspect500 hr1 moReplace as recommended.
Zinc AnodeReplace500 hr12 moMonthly, 100-Hr; Model MDKAU does not have a zinc anode to replace.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAir gap0.5mm
ClearanceAir gap0.8mm
ClearanceAir gap (rotor to stator)0.5mm
ClearanceAir gap (rotor to stator)0.7mm
ClearanceCrankshaft side clearance0.15 to 0.31mm
ClearanceCylinder head surface flatness allowable limit0.05mm
ClearanceCylinder liner I.D. (standard)67.000 to 67.019mm
ClearanceFan belt deflection12 to 14mmunder load of 98 N (22.1 lbs.), pressed in middle of span
ClearanceFan belt tension (deflection)12 to 14mm (0.47 to 0.55 in.)pressed in middle of the span under load of 98 N (22.1 lbs.)
ClearanceGenerator brush length (allowable limit)4.5mm
ClearanceGenerator brush length (allowable limit)7.5mm
ClearanceGenerator brush length (standard)15.0mm
ClearanceOil clearance between crankpin and crankpin bearing0.020 to 0.051mm
ClearancePiston ring gap, top ring0.15 to 0.30mm
ClearanceSlip ring outside diameter49.7mm
ClearanceSlip ring outside diameter64.0mm
ClearanceSlip-ring outside diameter49.7mmcorrection limit 47.5 mm
ClearanceSlip-ring outside diameter64.0mmcorrection limit 62.5 mm
ClearanceTop clearance0.50 to 0.70mm
ClearanceV-Belt Tension Deflection0.4inch (10 mm) @ 20 lbs (10 kg)
ClearanceV-belt deflection0.4 inch (10 mm)inch (mm)20 lbs (10 kg) applied to middle of pulley span
ClearanceV-belt deflection3/8inch (10 mm) at 20 lbs (10 kg) applied
ClearanceV-belt deflection at 20 lbs (10 kg)3/8 inch (10 mm)in (mm)tension check at middle of pulley span
ClearanceV-belt deflection at middle of pulley span3/8 inch (10 mm)with 20 lbs (10 kg) applied
ClearanceValve Lash (cold) - D1105/V1505/V2003M/V2403M0.0071-0.0087in (0.18-0.22 mm)cold
ClearanceValve Lash (cold) - V3300-E2B0.009-0.010in (0.23-0.27 mm)cold
ClearanceValve recessing (intake and exhaust)0.10 protrusion to 0.10 recessingmm
CompressionCompression Ratio (MDKAV/MDKAW/MDKAZ)22:1
CompressionCompression Ratio (MDKBD/MDKBE/MDKBF)23:1
GapFan belt deflection7.0 to 9.0mmat 98 N (10 kgf, 22 lbf)
GapV-belt deflection0.4inch (10 mm)20 pounds (10 kg) applied to middle of pulley span
Injection timingFuel Injection Timing12 deg BTDCdeg BTDC
Injection timingFuel Injection Timing13.5-15 deg BTDCdeg BTDC
Injection timingFuel Injection Timing14.25-15.75 deg BTDCdeg BTDC
Injection timingFuel Injection Timing14.75-16.25 deg BTDCdeg BTDC
Injection timingFuel Injection Timing15.5 - 17.5° BTDC
Injection timingFuel Injection Timing18° – 20°BTDC
Injection timingFuel Injection Timing - D110514.75-16.25° BTDC
Injection timingFuel Injection Timing - V150514.25-15.75° BTDC
Injection timingFuel Injection Timing - V2003M13.5-15° BTDC
Injection timingFuel Injection Timing - V2403M13.5-15° BTDC
Injection timingFuel Injection Timing - V3300-E2B12° BTDC
Injection timingFuel injection timing12degrees BTDC
Injection timingFuel injection timing14.5degrees BTDC
Injection timingFuel injection timing15.5 - 17.5 degrees BTDCdegrees BTDC
Injection timingFuel injection timing16degrees BTDC
Injection timingFuel injection timing16.5degrees BTDC
Injection timingFuel injection timing18 - 20degrees BTDCtiming marks line up at 19 degrees BTDC
Injection timingInjection pump timing0.33 to 0.37 rad (19 to 21° before TDC)rad
Injection timingInjection timing0.30 to 0.33 rad (19 to 21° before TDC)rad
OtherAnti-freeze 50 vol% boiling point108°Cat 1.013 x 10^5 Pa (760 mmHg)
OtherAnti-freeze 50 vol% freezing point-37°C
OtherBattery cable gauge1AWGtotal cable length 22 ft (6.7 m); approx. diameter 9.43 mm
OtherBattery cable gauge1/0AWGtotal cable length 30 ft (9.1 m); approx. diameter 9.46 mm
OtherBattery cable gauge2AWGtotal cable length 18 ft (5.5 m); approx. diameter 7.42 mm
OtherBattery cable gauge3AWGtotal cable length 14 ft (4.3 m); approx. diameter 6.61 mm
OtherBattery cable gauge4AWGtotal cable length 10 ft (3 m); approx. diameter 5.88 mm
OtherBattery charging rate (constant)6.0Ainitial battery charge
OtherBattery electrolyte specific gravity1.270 to 1.290at 20 degrees C (68 degrees F)
OtherBattery electrolyte specific gravity at charge completion1.27 to 1.29charge completed

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50/50 ethylene glycol long-life coolant (LLC) and clean soft waterSAE J1034 / SAE J814c3.7 LKubota genuine LLC has 2-year service life
Coolant50/50 mix of long-life coolant (ethylene glycol type) and clean soft waterSAE J1034 / SAE J814c3.7 LIncluding reserve tank 0.6 L; change every 2 years; flush radiator with fresh water before use
Coolant50/50 water/ethylene glycol2.1 LMDKBH; also stated as 2.2 Qt
CoolantClean water (soft water) with antifreeze 50/50Permanent type (PT) antifreeze; refer to SAE J1034 / SAE J814c; 40 vol% freezing point -24 °C, 50 vol% -37 °C3.7 LAntifreeze mixing ratio must be less than 50 %
CoolantClean water (soft water), antifreeze 50/503.7 LGL6000, GL7000; anti-freeze mixing ratio less than 50 %
CoolantEthylene glycol (EG) type long-life coolant, 50/50 mix with clean soft waterSAE J1034; SAE J814c3.7 LGL6000/GL7000 (Z482); 3.7 L (3.9 U.S.qts.), include reserve tank 0.6 L (0.63 U.S.qts.); change every 2 years
CoolantFleetguard ES Compleat / EG Premix antifreeze (ethylene glycol based)Purple coloured viscous liquid; boiling point 107 C, flash point 121 C.
CoolantFleetguard ES Compleat and EG Premix (ethylene glycol based)
CoolantGLYSANTIN PROTECT PLUS / G48antifreeze suitable for aluminium (monoethylenglycol with inhibitors)Mixture water:antifreeze 70:30=-20°C; 65:35=-25°C; 60:40=-30°C; 55:45=-35°C; 50:50=-40°C
CoolantLong-life coolant (LLC), ethylene glycol type, 50/50 with clean soft waterSAE J1034 / SAE J814c3.7 LGL6000, GL7000 (Z482); change every 2 years; includes reserve tank 0.6 L; GL9000/GL11000 (D722) = 4.1 L
CoolantPure water and anti-freeze0.6 Lreserve tank volume; all seasons
Coolant50/50 ethylene glycol/waterASTM D5345 (prediluted) or ASTM D4985 (concentrated, 40-60% quality water)above -37°CProtects to -34°F (-37°C)
Coolant50/50 ethylene glycol/water mixtureFully formulated with rust inhibitors and coolant stabilizersabove -37°C5.0 literMDKAW, MDKAZ
Coolant50/50 mixture of water and ethylene glycolASTM D5345 for 50/50 prediluted coolant or ASTM D4985 for concentrated coolant with 40% to 60% quality waterabove -37°CProtection from freezing down to -34 F (-37 C); use fresh low-mineral water, distilled best. Coolant capacity: 4.0 liter MDKBK/MDKBL; 5.0 liter MDKBM/MDKBN; 7.6 liter MDKBP/MDKBR/MDKBS; 13.7 liter MDKBT/MDKBU
Coolant50/50 mixture of water and ethylene glycol antifreezeFully formulated with rust inhibitors and coolant stabilizers; use low-mineral fresh water (distilled best)above -37°C4.0 literMDKAV, MDKBG; mixture good for -34 F (-37 C)
Coolant50/50 mixture of water and ethylene glycol antifreeze, fully formulated with rust inhibitors and coolant stabilizersASTM D5345 for 50/50 prediluted coolant or ASTM D4985 for concentrated coolant with 40% to 60% quality waterabove -37°C50/50 mixture gives protection from freezing down to -34 F (-37 C); use fresh water low in minerals and corrosive chemicals (distilled best)
CoolantEthylene glycol antifreeze, 50/50 mixture of water and ethylene glycolASTM D5345 for 50/50 prediluted coolant or ASTM D4985 for concentrated coolant with 40% to 60% quality waterabove -37°CProvides protection from freezing down to -34 F (-37 C). Use fresh water low in minerals; distilled water is best. Fully formulated with rust inhibitors and coolant stabilizers.
CoolantEthylene glycol antifreeze, fully formulated with rust inhibitors and coolant stabilizers; 50/50 mixture of water and ethylene glycolabove -37°C2.1 literProtection from freezing down to -34°F (-37°C); use fresh water low in minerals, distilled best
Coolantethylene glycol antifreeze, 50/50 mixture with waterabove -37°CGood to -34F (-37C)
Coolantethylene glycol antifreeze, 50/50 mixture with water for freeze protection to -34°F (-37°C)ASTM D5345 (50/50 prediluted) or ASTM D4985 (concentrated, 40-60% quality water)above 37°Cdistilled water best
Engine oilAPI classification CF, CF-4, CG-4, CH-4 or CI-4 with ultra low sulfur fuel; CF with high sulfur fuel2.2 LGL6000/GL7000 (engine Z482); 2.2 L (2.3 U.S.qts.)
Engine oil10W-30 or 10W-40API CF or higherbelow 10°Cbelow -10C
Engine oil10W-30 or 10W-40 or 15W-40API CF or higher / MIL-L-2104Cabove 25C use 10W-30/10W-40/15W-40
Engine oil15W402.1 LMDKBH; also stated as 2.2 Qt. Shipped with 15W40 engine oil.
Engine oilAPI CH-4 or better, SAE 15W-40 recommended year-roundAPI/SAESynthetic motor oil not recommended
Engine oilAPI Service Category CI-4 or better; SAE 15W-40 recommended year-roundAPIchoose viscosity per Figure 3-1 ambient chart
Engine oilAPI service class CF or higherMIL-L-2104C2.2 LChange oil type according to ambient temperature
Engine oilCFHigh Sulfur Fuel [>0.05% (500 ppm)]Other than North American market; halve intervals if CF-4/CG-4/CH-4/CI-4 used with high-sulfur fuel
Engine oilCF, CF-4, CG-4, CH-4 or CI-4Ultra Low Sulfur Fuel [<0.0015% (15 ppm)]North American market; CJ-4 intended for DPF type engines
Engine oilCF-4, CG-4, CH-4 or CI-4Low Sulfur Fuel [<0.05% (500 ppm)] or Ultra Low Sulfur Fuel [<0.0015% (15 ppm)]Other than North American market

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

38
CodeNameMeaningSeverityAction
1One blinkShutdown due to high engine temperatureShutdownOpen sea valve; clean sea water strainer; check coolant level and repair leaks; check/replace raw water hoses; readjust a loose pump belt (p. 4-9); replace worn raw water impeller (p. 4-10); clean heat exchanger (p. 4-12); check through-hull; drain/clean cooling system (p. 4-6); replace coolant thermostat (p. 4-8); tighten coolant sender E2 ring terminal; test/replace sender E2; check continuity Pin 9 to E2
12OvervoltageOutput voltage jumped to more than 125% of rated for 75 ms or more than 115% of rated for 3 s after voltage regulation enabledShutdownSee an authorized Onan service representative.
13UndervoltageOutput voltage fell to less than 90% of rated for 5 seconds after voltage regulation enabledShutdownTurn line breaker OFF, disconnect PTO, reduce loads; fill fuel tank; check fuel fittings and filters; replace fuel filters.
14OverfrequencyFrequency jumped to more than 70 Hz for 40 ms or more than 2% over nominal for 6 secondsShutdownReset breaker after starting, tighten fuel fittings, prime fuel system
15UnderfrequencyFrequency fell to less than 90% of nominal for more than 8 seconds during normal operationShutdownTurn breaker OFF, de-energize PTO, reduce loads; fill fuel; prime fuel system; remove air/exhaust blockages; check fuel fittings; replace fuel filters; check for contaminated fuel.
17OverprimePrime mode exceeded 5 minutesShutdownRemove object holding control switch in prime position
2Two blinksTwo blinks indicate shutdown due to low oil pressure.ShutdownCheck oil level; tighten sender E1 ring terminal; check sender E1 resistance and replace if necessary; check continuity Pin 10 to E1; replace sender with a gauge and service the engine lubrication system if oil pressure is less than 14 psi (98 kPa)
22Governor OverloadMaximum allowable time at full-duty cycle was exceededShutdownReduce the number of appliances running at the same time; check the fuel tank and fill; remove any blockage in the combustion air inlet or exhaust system; check fuel fittings for leaks and reprime; replace the fuel filters and reprime.
23Faulty Oil Pressure SenderController sensed grounded senderWarningTighten the ring terminal on sender E1; check continuity between Pin 10 and ring terminal E1-1; test sender E1 and replace as necessary; replace the genset controller
24Faulty Temperature SenderController sensed open senderWarningTighten the ring terminal on sender E2; check continuity between Pin 9 and ring terminal E2-1; test sender E2 and replace as necessary; replace the genset controller
27Loss of Voltage SenseThe genset Controller lost VAC sensing during normal voltage regulation when the field was functioning normally and frequency was at least 40 HzShutdownSee an authorized Onan service representative.
29High Battery VoltageDuring startup the genset Controller sensed that battery system voltage was greater than 19.2 voltsWarningCheck battery voltage, battery connections, battery charge rate.
3Three blinksThree blinks indicate shutdown requiring service by trained and experienced service personnel.WarningSee Troubleshooting in the Operator's Manual
32Starting FaultThe genset Controller could not detect cranking speed (quadrature zero crossings) for 3 secondsShutdownHave the propulsion engines running while trying to start the genset; service the battery; change to oil of proper viscosity for the ambient temperature.
35Control Card Failure–EEMicroprocessor EEPROM error during self-testShutdownVerify fault.
36Unknown ShutdownThe genset Controller declared this fault because engine speed fell below 1000 RPM for 0.5 seconds, though not by genset or engine control actionShutdownReduce the number of loads on the genset; check fuel level and refill; prime the fuel system for at least 30 seconds; check fuel fittings for leaks and reprime; replace the fuel filters and reprime.
37Invalid Set ConfigurationThe genset controller is not configured properly for the gensetWarningSee an authorized Onan service representative.
38Field OverloadHigh field voltage induced by high rotor temperature or low power factor loadsShutdownRemove generator air flow blockages; reduce appliances; have air conditioners and other appliances checked.
4OvercrankShutdown due to a failure to start within the time allowed for crankingShutdownPush line circuit breaker OFF; check fuel tank and fill; remove combustion air or exhaust blockages; open closed fuel valves; prime the fuel system at least 30 seconds; service the battery; check all fuel filters and fittings and reprime; replace fuel filters; change to proper oil viscosity; conduct fuel pump test; inspect glow plugs; service fuel injectors and worn engine
41Grounded RotorF+ groundedShutdownVerify fault.
42Processor FailureMicroprocessor ROM error during self-testShutdownVerify fault.
43Processor FailureMicroprocessor RAM error during self-testShutdownVerify fault.
45Speed Sense LostController lost speed sense (quadrature zero crossings) for 0.25 seconds after start disconnectShutdownSee an authorized Onan service representative.
46Genset OverloadThe genset Controller shutdown the genset because engine load exceeded 135 percent of genset rating for 10 secondsShutdownReduce the number of loads on the genset.
48Processor FailureController unable to sense field voltageShutdownVerify fault.
5Warning—Shutdown Due to Vessel COShutdown due to Vessel COWarningGet everyone out into fresh air immediately and seek medical attention.
57OverprimeA local or remote control switch was held in the Prime position for more than 5 minutesWarningRemove object holding switch in prime position, replace faulty control switch
58High Exhaust TemperatureExhaust temperature rises because of loss of waterShutdownReconnect/replace raw water hoses, replace impeller
59Low Coolant LevelThe engine coolant level fell below the optional coolant level sensorWarningAdd coolant, repair leaks
61External ShutdownThe generator set was shut down by a fire suppression system or other external controlShutdownMake necessary repairs and reset the external control which shut down the genset
7Seven blinksWater stops flowingShutdownOpen the sea cock; check for and clean a blocked sea water strainer; check for kinked or leaking hoses; check/replace the raw water impeller; check the hull through-hull fitting for blockage.
AEngine faultLow engine oil pressure or high engine coolant temperatureShutdownSee General Troubleshooting — low oil pressure & high engine coolant temperature.
A+CEngine overspeed or engine underspeedEngine overspeed or engine underspeedShutdownCheck connection on W terminal of DC Charge Alternator (MLTS)—WH/VI to pin-9 or Engine ECU (MLTS-K) on Power Zone controller. Inspect function of DC charge alternator. Inspect tension of DC charge alternator drive belt. Contact Generac Mobile.
BLow batteryLow batteryWarningCheck battery condition.
B+CLoss of speed signalLoss of speed signalWarningCheck connection on W terminal of DC Charge Alternator (MLTS)—WH/VI to pin-9 or Engine ECU (MLTS-K) on Power Zone controller. Inspect function of DC charge alternator. Inspect tension of DC charge alternator drive belt. Contact Generac Mobile.
CFail to crankFail to crank (AUTO mode only)WarningSee General Troubleshooting — fail to crank.
Code No. 5Warning - Shutdown due to Vessel COShutdown occurring due to the vessel CO detectorWarningAll status indicator lights in the control circuit will also blink the fault code. See Troubleshooting Chapter of the Operator Manual.
Code No. 61Emergency ShutdownShutdown occurring due to external emergency shutdown deviceShutdownAll status indicator lights in the control circuit will also blink the fault code. See Troubleshooting Chapter of the Operator Manual.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjusting Fan Belt Tension adjustment

⚠ Be sure to stop the engine and remove the key before checking the belt tension.

⚠ Be sure to reinstall the detached safety shield after maintenance or checking.

  1. Stop the engine and remove the key.
  2. Apply moderate thumb pressure to belt between pulleys.
  3. If tension is not as specified, loosen the lock nut and turn the adjust nut to get belt tension within range.
  4. Tighten up the lock nut.
  5. Replace fan belt if it is damaged.
Adjusting Frequency adjustment

Tools: Screwdriver

  1. Remove access cover on left end of genset.
  2. Find leads marked J8 HZ, 60 HZ and 50 HZ in wiring harness.
  3. Connect 60 HZ or 50 HZ lead to J8 HZ as appropriate.
  4. Secure access cover with four screws.
Adjusting High-Idle Speed adjustment

⚠ Keep your hands away from the engine belt and pulleys.

⚠ The actuator could overheat if the battery is left on more than 10 minutes.

⚠ Be prepared to clamp off supply and return fuel lines to stop the engine.

Tools: strobe or injector clamp-on tachometer, 12 volt battery, battery switch

  1. Adjust the speed control lever stop.
  2. Measure engine speed with a strobe or injector clamp-on type tachometer.
  3. Remove the front and top access doors and loosen the front/left side panel assembly for access to the speed adjusting screw.
  4. Disconnect the actuator leads and connect a 12 volt battery to the actuator terminals using a battery switch.
  5. Switch the battery on, start the genset, measure engine speed (rpm) and stop the engine by switching off the battery.
  6. Loosen the lock nuts on the two bottom screws and back out the clamping screw if speed is not between 3300 and 3400 rpm.
  7. To increase speed turn the speed adjusting screw in 1 turn clockwise; to decrease turn it out 1 turn counterclockwise.
  8. Repeat until high-idle speed is between 3300 and 3400 rpm and set the lock nut.
  9. Run the clamping screw in by hand until snug, back it out 1-1/2 turns and set the lock nut.
Adjusting Speed Control Lever Stop adjustment

⚠ Accidental or remote starting can cause severe personal injury; disconnect the negative battery cable.

  1. Remove the front and top access doors and loosen the front/left side panel assembly so it can swing left.
  2. Loosen the stop screw locknut and back the screw out a few turns.
  3. Turn the stop screw in until it just makes contact and set the locknut.
Adjusting V-Belt Tension adjustment

⚠ Accidental or remote starting can cause severe personal injury or death.

  1. Disconnect the negative cable at the battery.
  2. Remove the belt guard or enclosure top panel and access doors.
  3. Loosen the alternator pivot bolt first, then the adjusting bracket bolt on top.
  4. Pivot the alternator out to tighten belt tension.
  5. Check tension by applying 20 pounds (10 kg) to the middle of the pulley span.
  6. Tighten alternator bolts when deflection is 3/8 inch (10 mm), secure guard and reconnect cables, negative last.
Adjusting Valve Clearance adjustment

⚠ Valve clearance must be checked and adjusted when engine is cold.

Tools: Feeler gauge

  1. Remove the head cover, the glow plugs and the timing window cover.
  2. Align the 1TC mark line on the flywheel with center of timing window for No. 1 piston.
  3. Check valve clearance with a feeler gauge.
  4. Adjust with the adjusting screw if not within factory specification.
  5. Turn flywheel 6.28 rad (360°) and adjust all other valve clearances.
  6. Recheck clearance and firmly tighten the lock nut.
Adjusting Valve Lash adjustment

⚠ Do not use the fuel injection timing marks when adjusting valve lash.

  1. Rotate the engine clockwise (looking from the front) until the intake valve push rod just stops moving down (valve closed).
  2. Turn the engine one half turn more.
  3. Adjust lash for both intake and exhaust valves of that cylinder.
  4. Repeat this procedure for the other cylinder.
Adjusting Voltage adjustment

⚠ Hazardous voltage; touching live parts can cause severe personal injury or death

Tools: Accurate AC voltmeter and frequency meter

  1. Disconnect all generator loads and connect accurate AC volt and frequency meters.
  2. Start genset and let voltage and frequency stabilize 5 to 10 seconds.
  3. Rapidly press control switch to START 6 times within 10 seconds.
  4. Amber lamp blinks once per second to confirm voltage set mode.
  5. To raise voltage, press START and release quickly (about 0.6 volt per step).
  6. To lower voltage, press START and release in approximately 2 seconds.
  7. Normal operation resumes 20 seconds after last adjustment.
Adjusting Voltage Using Control Switch adjustment

Tools: separate voltmeter

  1. Start the genset and let voltage and frequency stabilize for 5 to 10 seconds with all loads disconnected.
  2. Rapidly press START 6 times during the first minute after startup to enter voltage adjust mode.
  3. To adjust voltage up, press and quickly release START (about 0.6 volts per press).
  4. To adjust voltage down, press and hold START for about 2 seconds (about 0.6 volts each press).
  5. Wait about 20 seconds for the amber lamp to stop blinking, then press STOP to save the adjustment.
  6. Restart the genset and check voltage.
Adjusting Voltage Using Digital Display adjustment
  1. Start generator set and let voltage and frequency stabilize 5 to 10 seconds; disconnect all loads.
  2. Rapidly press START 6 times during the first minute after startup to enter voltage adjust mode.
  3. Press and quickly release START to increase voltage approximately 0.6 volts per press.
  4. Press and hold START about 1 second to adjust voltage down.
  5. Wait about 20 seconds for status to change from Volt Adj to Running, then press STOP to save.
  6. Restart the generator set and check voltage; recalibrate AC voltage on the digital display.
Adjusting Voltage Using Optional Digital Display adjustment

Tools: Separate voltmeter

  1. Start the genset and let voltage and frequency stabilize for 5 to 10 seconds; make sure all loads have been disconnected.
  2. Rapidly press START 6 times during the first minute after startup to put the genset controller into voltage adjust mode.
  3. To adjust voltage up, press and quickly release START; voltage increases approximately 0.6 volts each press and release.
  4. To adjust voltage down, press and hold START for about 1 second; voltage decreases approximately 0.6 volts each press and release.
  5. Wait about 20 seconds for the Display to indicate a Status change from Volt Adj to Running, then press STOP to stop the genset and save the adjustment.
  6. Restart the genset and check voltage.
  7. Recalibrate AC Voltage on the Digital Display as instructed in the Operator's Manual.
Changing Frequency adjustment
  1. The genset control box has jumper leads marked HZ SEL and 60 HZ.
  2. Connect for 60 HZ; disconnect for 50 HZ.
  3. Apply the appropriate reconfiguration label over the 'As Manufactured' block on the nameplate.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
220 V - 50 Hz / shore power selectorL1 / L2 / L3 / L1' / NTerminals to be checked and labelled by the installation electrician (230 V - 50 Hz model)
50 Hz: Disconnect J5 from P7J5, P6, P7Frequency selection jumper leads in the genset control box
60 Hz (120 V)L1 / L2 / L3 / N & 1 / 2 / 4Terminals to be checked and labelled by the installation electrician (60 Hz 120 V model)
60 Hz: Connect J5 to P6J5, P6, P7Frequency selection jumper leads in the genset control box
DVS - 50 HzL1, L2, L3, L1'Contacts to be measured for short-circuit check
DVS - 60 HzL1, L2, L3, L1', 1, 2, 3, 4For the 60 Hz version both partial windings must be connected, i.e. a connection between wire 1 and 3 (see circuit plan)
HP1 - 50 HzL, ZContacts to be measured for short-circuit check (per type plate)
HP1 - 60 HzL, ZContacts to be measured for short-circuit check
HP3 - 50 HzL1, L2, L3Contacts to be measured for short-circuit check
HP3 - 60 HzL1, L2, L3, 1, 2, 3, 4Contacts to be measured for short-circuit check
HZ SEL / 60 HZ jumper leads in the control boxHZ SEL, 60 HZConnect for 60 Hz; disconnect for 50 Hz. Apply the appropriate reconfiguration label. Generator reconnection per schematic on Page A-2.
110 / 220 V1 - 4GL7000-STD, 60 HzMain coil R - W 0.25 ohm; BR - L 0.25 ohmNFB capacity 29.5 A
110/2201Main coilR - W; BR - LGL7000-STD; 0.25 Ω each
110/2201Single phase 3 terminals type (1P4W type) dual voltageGL7000-STD, 60 Hz
120 / 240 V1 - 3GL11000-USA, GL11000-USA-TM, 60 HzMain coil 1 - 3: 0.23 ohm; 1 - 2 and 2 - 3: 0.12 ohm; sub coil LG - LG 1.68 ohm; rotor coil 55.5 ohmNFB capacity 42 A; GL11000-STD (110/220 V) main coil 0.19 / 0.10 / 0.10 ohm, sub coil 1.73 ohm, NFB 45.5 A
120 / 240 V1 - 4GL7000-USA, GL7000-USA-TM, 60 HzMain coil R - W 0.28 ohm; BR - L 0.28 ohmNFB capacity 27.5 A
120/2401Main coilR - W; BR - LGL7000-USA; 0.28 Ω each
120/2401Receptacle outputGL7000-USA, GL11000-USA, 60 Hz
120/2401Single phase 3 terminals type (1P4W type) dual voltageGL7000-USA-TM, 60 Hz
2201Main coilR - WGL6000-STD; 0.55 Ω
2201Single phase 2 terminals typeGL6000-STD, GL9000-STD, 50 Hz
220 V1 - 2GL6000-STD, 50 HzMain coil R - W: 0.55 ohmSub coil G - LG/R 1.08 ohm; sub coil (DC) L/W - L/W 0.11 ohm; detecting coil LG - L 0.05 ohm; rotor coil 59.5 ohm
220 V1 - 3GL9000-STD, 50 HzMain coil 1 - 3: 0.28 ohm; sub coil LG - LG 1.96 ohm; detecting coil R - R 0.04 ohm; rotor coil 55.5 ohmNFB capacity 36.5 A; 240 V (GL9000-AUS) 0.34 ohm, NFB 33.5 A
220/208312 Lead ReconnectableApplies to MDKDP (60 Hz), MDKDR (60 Hz), MDKDS
220/380312 Lead ReconnectableApplies to MDKDP, MDKDR, MDKDT, MDKDU
2401Main coilR - WGL6000-AUS; 0.62 Ω
2401Receptacle outputGL6000-AUS, GL9000-AUS, 50 Hz
240 V1 - 2GL6000-AUS, 50 HzMain coil R - W: 0.62 ohmNFB capacity 23 A
3-phase312 Lead ReconnectableApplies to MDDCW, MDDCU, MDDCY, MDDCS, MDDCT

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Kubota Z482 family

94
Part #DescriptionCategory
1556211081Air CleanerAir filter
3415013964Element air cleanerAir filter
8742031004Bracket air cleanerAir filter
G3102-8839-0Air cleanerAir filter
W1020554Damage in Electric Wiring and Loose ConnectionsAir filter
07916-34041Auxilary Socket for Fixing Crankshaft SleeveAuxiliary socket for fixing crankshaft sleeve
G3102-8833-0BatteryBattery
W1053554BatteryBattery
1980572531Fan BeltBelt
G3102-8832-0V-beltBelt
07909-31661Connecting Rod Alignment ToolConnecting rod alignment tool
W1062553Connecting Rod Small End Bushing ToolConnecting rod small end bushing tool
G3102-8831-0Coolant filterCoolant filter
07916-32011Flywheel PullerFlywheel puller
G3102-8838-0Fuel filterFuel filter
GL6000Fuel filter cartridge or elementFuel filter
GL9000Fuel filter cartridge or elementFuel filter
G3102-8830-0GasketGasket
0207008000HEX. NUTHex nut
0199900550Drain HoseHose
0199900650HoseHose
0199900700Drain HoseHose
0605515003Hose Band F-30Hose
0605515006Hose Band F-50Hose
0605515021Hose Band F-55Hose
0605515094Hose Band F-12Hose
0605515111Hose Band F-34Hose
1612036203Hose air cleanerHose
7222016304HoseHose
8742032003Hose Air cleanerHose
D2312500003Radiator HoseHose
D2312500103Radiator HoseHose
D2322400004Hose JointHose
W1040289Idle Gear Bushing Replacing ToolIdle gear bushing replacing tool
21.03.02.005SSpare part kit (impellerfilter)Impeller
31.06.03.003PImpellerfilter for Marine Panda P6, P8, P9, P10, P12 and P14 (tested for a flow rate up to 22 l/min)Impeller
W10252400Injection Pump Pressure TesterInjection pump pressure tester
7000015241Cartridge Oil FilterOil filter
G3102-8841-0Oil filter cartridgeOil filter
HH150-32094OIL FILTEROil filter
HH150-32430OIL FILTEROil filter
W1037215Engine Oil Filter CartridgeOil filter
07916-32032Oil Pressure TesterOil pressure tester
0010108050Hex Head BoltService part / kit
0012410020Hex Head BoltService part / kit
0016906016Hex Head BoltService part / kit
0016906025Hex Head BoltService part / kit
0016908030Hex Head BoltService part / kit
0030006000Hex NutService part / kit
0042806000Plain WasherService part / kit
0050403020Spring PinService part / kit
0150000018O Ring A P18Service part / kit
0207010000Hex NutService part / kit
0207206000Hex NutService part / kit
0222600340Rubber CushionService part / kit
031108160PLAIN WASHERService part / kit
0601806640FUSE, 65AService part / kit
0602012750RadiatorService part / kit
0602081104Cap reserve tankService part / kit
0605000460Rubber MountService part / kit
0605010503Snap Pin SS-P8Service part / kit
0802011104PlugService part / kit
0802081403Reserve TankService part / kit
12567Canopy HardHat®Service part / kit
1502025103Drain Joint oilService part / kit
1622014103Drain Joint waterService part / kit
1622082104Bracket reserve tankService part / kit
16226361032Hex Head BoltService part / kit
162520004Rotary SolenoidService part / kit
1992636004Arm SolenoidService part / kit
21.02.02.009HGenerator Control Panel P6+ (12V version, RE0703)Service part / kit
21.02.02.015HOption master-slave adapterService part / kit
21.02.02.016HOption automatic adapterService part / kit
21.02.02.046HGenerator Control Panel P6+ 12V versionService part / kit
21.02.02.047HGenerator Control Panel P6+ 24V special versionService part / kit
505015300Snap Pin SS-P6Service part / kit
7085419004Rubber SuspensionService part / kit
8702014004InsulatorService part / kit
8745112003Engine FootService part / kit
A592520004EngineService part / kit
D235630004Governor RodService part / kit
G3907-8830-0Danger/warning/caution label (2)Service part / kit
G3907-8832-0Danger/warning/caution label (1)Service part / kit
PMGPN610U19Cap 19mmService part / kit
W1022492Intake and exhaust valve clearance (Cold)Service part / kit
W1024734Ball BearingService part / kit
W10411400Radiator CapService part / kit
07909-30241PlastigagePlastigage
07909-31371Red CheckRed check
G3102-10011Rotor Pulling Out Bolt (for GL6000, GL7000)Rotor pulling out bolt
F1379Siphon Break KitSiphon break
G3102-8836-0Spark plugSpark plug
07916-09032Special Use Puller SetSpecial use puller set
07909-33102Valve Seat CutterValve seat cutter

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Aftermarket parts that fit this engine

60
16851-35012 FridayParts $65.00 15841-74250 FridayParts $43.99 16853-99355 FridayParts $72.00 16853-99366 FridayParts $72.00 16851-22010 FridayParts $35.24 16851-22012 FridayParts $35.24 16851-22015 FridayParts $35.24 16851-22017 FridayParts $35.24 15694-65992 FridayParts $18.58 15694-65990 Amazon eBay $15.01 FridayParts $18.58 S81NL FridayParts $18.58 SN1NL FridayParts $18.58 1G687-22010 FridayParts $58.60 16604-52030 FridayParts $34.65 16851-52030 FridayParts $18.95 R1401-51352 FridayParts $18.95 R1401-51350 FridayParts $18.85 19026-73260 FridayParts $17.50 19026-732602 FridayParts $17.50 3Pcs FridayParts $9.90 SinoCMP $36.00 16001-53904 FridayParts $57.19 17214-72020 KuduParts $13.00 FridayParts $15.00 1E231-60011 FridayParts $49.99 16271-43560 Amazon eBay $18.89 NAPA $16.83 KuduParts $24.00 FridayParts $26.17 16851-52033 FridayParts $20.23 6C040-55412 FridayParts $27.20 15248-63590 FridayParts $27.20 1E411-60012 SinoCMP $79.00 FridayParts $112.00 4230021 FridayParts $38.20 16871-53002 FridayParts $41.70 16861-72020 KuduParts $7.00 FridayParts $9.60 16001-51012 FridayParts $345.00 SinoCMP $389.00 16001-51010 FridayParts $345.00 SinoCMP $389.00 15263-12370 Amazon eBay FridayParts $13.99 12582-12110 FridayParts $152.00 30-60037-00 FridayParts $189.99 30-60007-00 FridayParts $189.99 15841-39010 Amazon eBay FridayParts $9.50 15231-39010 FridayParts $9.50 15231-39013 FridayParts $9.50 12691-43010 KuduParts $7.00 FridayParts $9.65 13351-43010 KuduParts $7.00 FridayParts $9.66 16851-65510 FridayParts $25.00 15852-12310 FridayParts $95.99 1G311-43380 KuduParts $17.00 FridayParts $18.99 12597-74110 FridayParts $52.60 HH1J0-32430 FridayParts $32.99 23452GT FridayParts $11.00 52808GT FridayParts $11.00 GS-2668 FridayParts $9.99 SinoCMP $109.00 GS-3268 FridayParts $10.82 SinoCMP $109.00 GS-2669 FridayParts $11.00 GS-3369 FridayParts $11.00 GS-4069 FridayParts $10.99 Z-34/22 FridayParts $11.00 Z-45/22 FridayParts $11.00 H1600-53000 SinoCMP $45.00 FridayParts $55.78 16001-53000 FridayParts $55.78 15831‑43380 KuduParts $13.00 FridayParts $15.00 15221-65510 FridayParts $29.50

Parts listed by aftermarket suppliers as fitting this engine — leads compiled from supplier catalogs; verify the exact part for your serial number.

Filters for this engine

  • Air filter: Kubota 1522211223 Kubota RG15842930 Donaldson P102745 Donaldson P822686 Wix 46270 Ac Delco A527C Baldwin PA1865-FN Wix 46449
  • Fuel filter: Kubota 1522143081 Donaldson P557440 Donaldson P550127 Wix 33352 Ac Delco TP993 Baldwin BF970 Wix 33390 Ac Delco TP1200

Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.

Also used in

6
  • Carrier Transicold COMFORTPRO — Generator Set
  • Carrier Transicold SUPRA — Refrigeration Unit
  • Hitachi 08 — Construction Equipment
  • Hitachi EX8 — Excavator Compact
  • Hitachi EX8-2 — Excavator Compact
  • Hitachi EX8-2B — Excavator Compact

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the oil capacity of the Kubota Z482?

The Kubota Z482 engine has an oil capacity of 3.8 liters.

What is the displacement of the Kubota Z482?

The Kubota Z482 has a displacement of 0.479 liters with 2 cylinders.

Which generators use the Kubota Z482 engine?

The Kubota Z482 powers 19 generator set(s), including Cummins/Onan MDKB, Denyo DA-6000SS, FG Wilson KH6-1S, Fischer Panda 8000i PMS, Generac MLTS.

What fuel filter does the Kubota Z482 use?

The Kubota Z482 uses fuel filter part numbers Kubota 1522143081, Donaldson P557440, Donaldson P550127.

What air filter does the Kubota Z482 use?

The Kubota Z482 uses air filter part numbers Kubota 1522211223, Kubota RG15842930, Donaldson P102745.

How often should you change the oil in the Kubota Z482?

The Kubota Z482 oil change interval is every 200 hours.

What is a common problem with the Kubota Z482 engine?

A commonly reported issue on generators using the Kubota Z482 is: Use or operate the engine on or near any forest-covered, brush-covered land, or grass-covered land.. Fix: The exhaust system must be equipped with a working spark arrester meeting state laws..