Waukesha F1197-GRS1U Engine
The Waukesha F1197-GRS1U is a 2.99 L 6-cylinder natural aspiration engine rated at 1800 rpm. It powers generator sets from Cummins/Onan, including the WC Series. It holds 31.68 L (8.4 gal) of oil.
Also known as: Waukesha F1197-GRS1U
Part of the Waukesha F1197 engine family — 2 variants share parts & fitment.
Service parts for the F1197-GRS1U
The cheapest captured merchant offer per filter — see the full cross-reference below for every OEM/aftermarket option.
Oil system
1 required101737AOil filterfind
Prices captured from merchant listings; some links are affiliate links. Verify against your serial number before ordering.
Engine specifications
| Oil capacity | 31.68 L |
|---|
| Displacement | 2.98543 L |
|---|
| Cylinders | 6 |
|---|
| Aspiration | Natural Aspiration |
|---|
| Rated speed | 1800 rpm |
|---|
Generator sets powered by this engine
1
Common problems
13- Partial loss of residual in Rotor
Fix: With plant operating, jumper from E2 to heat sink of field rectifier Z until voltage begins to build-up. Then remove. - Output voltage slow to buildup.
Cause: Circuit breaker opens in about five seconds - Output voltage slow to build up and ten to twenty percent above rated voltage after build up
Cause: Open in one Field Rectifier or Open circuit in Gate winding G1-G2 of Reactor A or B
Fix: Test rectifiers and replace if defective. If Field Rectifiers Y and Z check okay, check continuities of Gate windings G1-G2 - Output voltage slow to build up and higher than rated voltage after build up
Cause: Open circuit in one or more Control Rectifier
Fix: Test rectifier and replace if defective. Check soldered connections to rectifiers - Output voltage slow to build up and five percent below rated voltage after build up. Voltage regulation poor.
Cause: Either Field Rectifier W or Z shorted
Fix: Test rectifiers and replace if defective - Output voltage builds up normally with slightly less than rated voltage at no load and low voltage at full load
Cause: Compound winding S1-S2 installed backward or has open circuit
Fix: Check wiring diagram for polarity of compound windings through Reactors A and B and test for continuity - Output voltage builds up normally but less than rated voltage after build up
Cause: Shorted winding in Control Reactor
Fix: Test Control Reactor and replace if defective - Output voltage builds up normally but is twenty-five percent above rated voltage after build up
Cause: Open circuit in Control Rectifier bridge
Fix: Check continuity from the junction of Control Rectifiers W and X to the junction of Control Rectifiers Y and Z - Output voltage builds up normally but 20-percent above rated voltage after build up. Voltage regulation poor.
Cause: Compound winding S1-S2 installed backward through one Reactor (A or B))
Fix: Check wiring diagram for polarity of Compound winding through Reactor A or B - No AC power to Magneciter
Fix: Check AC voltage at E1-E2 with the plant operating. Voltage should be five percent of the rated voltage. If not, check continuity from E1-E2 back to generator - Generator will not build up voltage.
Cause: Circuit breaker in 'off' or 'tripped' position
Fix: Reset and close breaker - Excessive charging rate (Battery requires too frequent filling)
Fix: Tighten connections, - Alternator fails to charge or puts out low or unstable charge rate
Cause: Alternator belt loose. Loose or dirty battery connections. Worn or defective brushes. Faulty regulator.
Fix: Tighten belt. Clean and tighten. Replace brushes. Replace regulator.
Compiled from service & troubleshooting documentation across every generator set that uses the Waukesha F1197-GRS1U.
Maintenance schedule
Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.
Parts cataloged across the Waukesha F1197 family
35| Part # | Description | Category |
|---|
| 191B649 | Pulley, Alternator | Alternator |
| 191B690 | Bracket, Alternator Mtg. - Begin Spec 'F' | Alternator |
| 234D70 | Band, Generator - Front Portion (Narrow) | Alternator |
| 332AI89 | Alternator, Charge | Alternator |
| 309A178 | Battery, 24V, 150Ah | Battery |
| 4I6A444 | Positive | Battery |
| 4I6A445 | Negative | Battery |
| A956 | 2-12 VOLT BATTERIES | Battery |
| 232AI808 | Bearing Holder - Anti-Rotation - Begin Spec B | Bearing holder |
| 234D74 | Generator Group (Exciter Portion) | Exciter panel |
| 232AI490 | Engine Oil | Fluid |
| 232AI817 | Onan OE Filter | Fuel filter |
| 505-19 | Bushing, Pipe Reducer (1/2 x 3/8") High Water Temperature Switch (1), Water Temperature Gauge Sender (1) | Oil filter |
| I93A100 | Sender, Water Temp. (Eng. Switch & Sender Unit Only) | Oil filter |
| I93A98 | Sender, Oil Press. (Eng. Unit Only) | Oil filter |
| 204A83 | Switch Assy., Overspeed | Service part / kit |
| 232AI807 | Rotor Assy., Wound, Inc. Brg., Blower & Drive Assy. | Service part / kit |
| 232AI813 | Spacer, Alternator Mtg. | Service part / kit |
| 232CI394 | Bolt. Place. Gen. Mtg. | Service part / kit |
| 234AI07 | Support, Gen. Mtg. | Service part / kit |
| 321-139 | .0598 " | Service part / kit |
| 321-140 | Holder, Fuse | Service part / kit |
| 332AI817 | Voltage Regulator | Service part / kit |
| 338B242 | Static Exciter | Service part / kit |
| 338B2I3 | Voltage Regulator | Service part / kit |
| 403C575 | Base, Mounting | Service part / kit |
| 4I6A446 | Cable, B a t t . Jpr. | Service part / kit |
| 4I6A96 | Clip. Ene. Cont.Harness | Service part / kit |
| 505-117 | Low Oil Press. Bushing, Rod (1/2 x 3/8") | Service part / kit |
| 505-131 | Bushing, Pipe Reducer (3/4 x 3/8") Radiator Outlet to Drain Valve | Service part / kit |
| 505-98 | Nipple, Close (1/8 x 3/4'') Oil Pressure Tee Mounting | Service part / kit |
| I9IC548 | Regulator, Charge | Service part / kit |
| I9IC550 | Bracket, Alternator | Service part / kit |
| 232AI376 | Rectifier | Rectifier |
| 336AI211 | Lead, Starter ( 14 " Long) | Starter |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
Filters for this engine
- Oil filter: Waukesha 101737A Donaldson P550117 Wix 51503 Ac Delco AC114
Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.
Also used in
1Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.
Common questions
What is the oil capacity of the Waukesha F1197-GRS1U?
The Waukesha F1197-GRS1U engine has an oil capacity of 31.68 liters.
What is the displacement of the Waukesha F1197-GRS1U?
The Waukesha F1197-GRS1U has a displacement of 2.98543 liters with 6 cylinders.
Which generators use the Waukesha F1197-GRS1U engine?
The Waukesha F1197-GRS1U powers 1 generator set(s), including Cummins/Onan WC Series.
What oil filter does the Waukesha F1197-GRS1U use?
The Waukesha F1197-GRS1U uses oil filter part numbers Waukesha 101737A, Donaldson P550117, Wix 51503.
How often should you change the oil in the Waukesha F1197-GRS1U?
The Waukesha F1197-GRS1U oil change interval is every 400 hours.
What is a common problem with the Waukesha F1197-GRS1U engine?
A commonly reported issue on generators using the Waukesha F1197-GRS1U is: Partial loss of residual in Rotor. Fix: With plant operating, jumper from E2 to heat sink of field rectifier Z until voltage begins to build-up. Then remove..