Cummins/Onan D2200 Engine

The Cummins/Onan D2200 is a 2.2 L engine rated at 1800 rpm. It powers generator sets from Cummins/Onan, including the C20 D6.

Also known as: Cummins D2200

2.2 L
Displacement
1800 rpm
Rated speed

Engine specifications

Displacement2.2 L
Rated speed1800 rpm

Common problems

11
  • Undervoltage sensor pickup and dropout adjustable from 85-100% and 75-98%
    Fix: Dropout adjustable delay from 0.1-30 sec.
  • Time delay start and stop (cooldown) configurable for time delay of 0-300 seconds prior to starting after receiving a remote start signal
    Fix: Control provides retransfer time delays including time delay emergency to normal (0-1800 sec), programmed transition delay (0-600 sec), and time delay engine cooldown (0-3600 sec).
  • Time delay of 0-600 seconds prior to shutdown after signal to stop in normal operation modes
    Fix: Default for both time delay periods is 0 seconds.
  • Sensor failure indication
    Fix: Logic is provided on the base control to detect analog sensor or interconnecting wiring failures.
  • Overvoltage sensor dropout adjustable from 105-135% of nominal
    Fix: Dropout adjustable delay from 0.5-120 sec.
  • Over/under frequency sensor underfrequency sensing pickup and dropout adjustable from 85-100% and 70-85%
    Fix: Dropout adjustable delay from 0.1-15 sec.
  • Over/under frequency sensor overfrequency sensing dropout adjustable from 105-115% of nominal
    Fix: Dropout adjustable delay from 0.1-15 sec.
  • Low lube oil pressure warning/shutdown
    Fix: Level is pre-set to match the capabilities of the engine used. Control includes time delays to prevent nuisance shutdown signals.
  • Low coolant temperature warning
    Fix: Indicates that engine temperature may not be high enough for 1 min. and start or proper load acceptance.
  • High coolant temperature warning/shutdown
    Fix: Level is pre-set to match the capabilities of the engine used. Control includes time delays to prevent nuisance shutdown signals.
  • Emergency stop signal is received
    Fix: The generator set immediately shuts down and cannot run or crank with the E-stop switch engaged.

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan D2200.

Service specifications

20
TypeItemValueUnitCondition
OtherAC waveform Total Harmonic Distortion (THDV)No load to full linear load < 5. For any single harmonic < 2.5%
OtherAFLEX-H (shake table test datum)<=3.200gAC156, tri-axial, 5% damping SRS
OtherAFLEX-V (shake table test datum)<=1.333gAC156, tri-axial, 5% damping SRS
OtherARIG-H (shake table test datum)<=2.400gAC156, tri-axial, 5% damping SRS
OtherARIG-V (shake table test datum)<=0.533gAC156, tri-axial, 5% damping SRS
OtherGovernor regulation classISO 8528
OtherGround snow load limit30psfFor indoor (covered) and outdoor (exposed) installation
OtherHorizontal design seismic coefficient (z/h = 0.0)1.440gCertified seismic design level, IBC Importance IP <= 1.5, Soil Classes A-E, Risk Categories I-IV, Design Categories A-F, SDS <= 2.000 g
OtherSDS (g) at z/h=1 for C10 D6 - C60 D62.0gCertified SDS, z/h = 1
OtherSDS (g) at z/h=1 for C50 D6C - C125 D6C2.5gCertified SDS, z/h = 1
OtherTelephone Harmonic Factor (THF)< 2%for 50 Hz
OtherTelephone Influence Factor (TIF)< 75for 60 Hz
OtherZPA-H (shake table test datum)<=2.160gAC156, tri-axial, 5% damping SRS
OtherZPA-V (shake table test datum)<=0.480gAC156, tri-axial, 5% damping SRS
SpeedFrequency regulationDroop
SpeedRandom frequency variation± 0.75%
TemperatureStandard temperature rise125-163ºC
VoltageRandom voltage variation± 2.5%
VoltageStarting voltage12Vnegative ground
VoltageVoltage regulation, no load to full load± 2.5%no load to full load

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantAntifreeze 50/50 (Ethylene glycol)Optional
FuelDiesel

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

5
CodeNameMeaningSeverityAction
27Low AC voltage shutdownVoltage on any phase has dropped below a preset value. Adjustable over a range of 50-95% of voltage, time delay 2-20 seconds. Default value is 90% for 5 seconds.Shutdown
51High Current warning/shutdownImplementation of the thermal damage curve with instantaneous trip level calculated based on current transformer ratio and application power rating.Warning
59High AC voltage shutdownOutput voltage on any phase exceeds pre-set values. Values adjustable from 105-125% of nominal voltage, with time delay adjustable from 1-10 seconds. Default value is 110% for 5 seconds.Shutdown
81 oOver frequency shutdown/warningGenerator set is operating at a potentially damaging frequency level. Settings are adjustable from 2-10 Hz above nominal governor set point for 100-2000 half cycles delay. Default: 5 Hz, 1000 half cycles.Warning
81 uUnder frequency shutdownGenerator set output frequency cannot be maintained. Settings are adjustable from 2-10 Hz below nominal governor set point, for a 500-2000 half cycles delay. Default: 5 Hz, 1000 half cycles.Shutdown

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the displacement of the Cummins/Onan D2200?

The Cummins/Onan D2200 has a displacement of 2.2 liters.

Which generators use the Cummins/Onan D2200 engine?

The Cummins/Onan D2200 powers 1 generator set(s), including Cummins/Onan C20 D6.

What is a common problem with the Cummins/Onan D2200 engine?

A commonly reported issue on generators using the Cummins/Onan D2200 is: Undervoltage sensor pickup and dropout adjustable from 85-100% and 75-98%. Fix: Dropout adjustable delay from 0.1-30 sec..