The Cummins/Onan KTA38-G2 is a turbocharged engine. It powers generator sets from Cummins/Onan, including the DFJB. It holds 129 L (34.1 gal) of oil and 323 L (85.3 gal) of coolant.
Also known as: Cummins KTA38-G2
Part of the Cummins/Onan KTA38 engine family — 17 variants share parts & fitment.
| Oil capacity | 129.0 L |
|---|---|
| Coolant capacity | 323.0 L |
| Aspiration | turbocharged |
How to read your Cummins/Onan engine serial & model number →
Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan KTA38-G2.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| crankcase oil | Change | 50 hr | First service — Drain and replace crankcase oil after the first 50 hours of operation on new generator sets; make a special entry in the unit log book. | |
| Rupture basin leak detect switch | Test | 12 mo | Check once a year; in some areas weekly inspections may be required by safety code regulations |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Angular alignment maximum T.I.R. | 0.001 | inch per inch of radius (center of shaft to indicator axis) | measuring deflection to bolt heads |
| Clearance | Float switch assembly float lift clearance below C-clip stop | 1/8 | inch (3 mm) | use a feeler gauge |
| Clearance | Generator-to-engine angular alignment (T.I.R.) | .001 in. per inch of radius (center of shaft to indicator axis), maximum | in | 750 kW gensets and larger |
| Clearance | Vibration isolator top plate clearance | 0.25 | in (6 mm) | nominal |
| Gap | MPU sensor to flywheel ring gear tooth | back it out one quarter turn | turn | sensor threaded in until it just touches gear tooth |
| Other | AVR Droop setting | 5 | % at full load, 0 PF | |
| Other | AVR voltage regulation (load regulation) | approximately ±0.5 | % RMS | |
| Other | Angular alignment maximum T.I.R. | .001 inches per inch of radius | in/in | center of shaft to indicator axis |
| Other | Battery specific gravity (high ambient, above 95F/35C) | 1.225 | recommended to reduce electrolyte loss | |
| Other | Battery specific gravity (recharge threshold) | below 1.260 | ||
| Other | Battery specific gravity, fully charged | approximately 1.260 | specific gravity | at 80 F (27 C) |
| Other | Fuel lift height limit | 6 | feet | (1.8 meters) between fuel lift pump and bottom of dip tube |
| Other | GOV GAIN default value for paralleling applications | 70 | % | |
| Other | Maximum angular alignment T.I.R. | 0.001 | in per inch of radius (center of shaft to indicator axis) | |
| Other | Maximum cranking voltage drop | 2 | volts | difference between battery and starter terminals while cranking |
| Other | Over/Under Frequency Sensor Module - Over Hz Set, 50 Hz nominal | 55 | Hz | reset 53 Hz |
| Other | Over/Under Frequency Sensor Module - Over Hz Set, 60 Hz nominal | 65 | Hz | reset 63 Hz |
| Other | Over/Under Frequency Sensor Module - Under Hz Set, 50 Hz nominal | 45 | Hz | reset 47 Hz |
| Other | Over/Under Frequency Sensor Module - Under Hz Set, 60 Hz nominal | 55 | Hz | reset 57 Hz |
| Other | Over/Under Voltage Sensor Module time delay | typically 25 percent, approximately 2.5 | seconds | |
| Other | Overcrank cranking limit | 75 | seconds | three 15-second cranking cycles with two 15-second rest periods |
| Other | REG VHZ (underfrequency roll-off) adjustable range | 1 through 50; normal range 7 through 21 | ||
| Other | Start delay adjustment range | 0 to 300 | seconds | |
| Other | Stop delay adjustment range | 0 to 600 | seconds | |
| Other | Under Frequency Roll Off (UFRO) knee point, 50 Hz units | 48 to 49 | Hz | |
| Other | Under Frequency Roll Off (UFRO) knee point, 60 Hz units | 58 to 59 | Hz | |
| Other | Under-frequency roll-off threshold (UFRO) | typically 59 Hz for 60 Hz applications and 49 Hz for 50 Hz applications | Hz | AVR UFRO pot preset |
| Pressure | Engine oil pressure - K19 normal | 50-70 | psi (345-482 kPa) | run mode |
| Pressure | Engine oil pressure - K38 normal | 45-65 | psi (310-448 kPa) | run mode |
| Pressure | Engine oil pressure - K50 normal | 50-70 | psi (345-482 kPa) | run mode |
| Pressure | Engine oil pressure - L10/M11 normal | 30-50 | psi (207-345 kPa) | run mode |
| Pressure | Engine oil pressure - NTA 855 normal | 35-50 | psi (241-345 kPa) | run mode |
| Pressure | Engine oil pressure - V28 normal | 50-90 | psi (345-620 kPa) | run mode |
| Pressure | Engine oil pressure gauge | 40 to 70 | psi (275 to 483 kPa) | engine at operating temperature |
| Pressure | Engine oil pressure shutdown limit - L10/M11 | 20 | psi (138 kPa) | run mode value |
| Pressure | Engine oil pressure shutdown limit - L10/M11 | 8 | psi (55 kPa) | idle mode value |
| Pressure | Engine oil pressure warning limit - L10/M11 | 12 | psi (83 kPa) | idle mode value |
| Pressure | Engine oil pressure warning limit - L10/M11 | 25 | psi (172 kPa) | run mode value |
| Pressure | K19 engine idle oil pressure | 20 | psi (138 kPa) | idle |
| Pressure | K19 engine normal oil pressure | 50-70 | psi (345-482 kPa) | normal run |
| Pressure | K19 oil pressure shutdown/warning limits | shutdown 35 psi (241 kPa) run; warning 40 psi (276 kPa) run; shutdown 10 psi (69 kPa) idle; warning 15 psi (103 kPa) idle | psi (kPa) | |
| Pressure | K38 engine idle oil pressure | 20 | psi (138 kPa) | idle |
| Pressure | K38 engine normal oil pressure | 45-65 | psi (310-448 kPa) | normal run |
| Pressure | K38 oil pressure shutdown/warning limits | shutdown 35 psi (241 kPa) run; warning 40 psi (276 kPa) run; shutdown 10 psi (69 kPa) idle; warning 15 psi (103 kPa) idle | psi (kPa) | |
| Pressure | K50 engine idle oil pressure | 20 | psi (138 kPa) | idle |
| Pressure | K50 engine normal oil pressure | 50-70 | psi (345-482 kPa) | normal run |
| Pressure | K50 oil pressure shutdown/warning limits | shutdown 35 psi (241 kPa) run; warning 40 psi (276 kPa) run; shutdown 10 psi (69 kPa) idle; warning 15 psi (103 kPa) idle | psi (kPa) | |
| Pressure | L10/M11 engine idle oil pressure | 15 | psi (103 kPa) | idle |
| Pressure | L10/M11 engine normal oil pressure | 30-50 | psi (207-345 kPa) | normal run |
| Pressure | L10/M11 oil pressure shutdown limit | 20 | psi (138 kPa) | run mode value |
| Pressure | L10/M11 oil pressure shutdown limit | 8 | psi (55 kPa) | idle mode value |
| Pressure | L10/M11 oil pressure warning limit | 12 | psi (83 kPa) | idle mode value |
| Pressure | L10/M11 oil pressure warning limit | 25 | psi (172 kPa) | run mode value |
| Pressure | Low oil pressure service limit while cranking | 10 | psi | service lubricating system if below |
| Pressure | Low oil pressure shutdown | below 14 | psi (97 kPa) | time delayed ~10 seconds following starter disconnect |
| Pressure | Low oil pressure shutdown threshold | 14 | psi | less than this value shuts down |
| Pressure | NTA 855 engine normal oil pressure | 35-50 | psi (241-345 kPa) | normal run |
| Pressure | NTA 855 oil pressure shutdown limit | 25 | psi (172 kPa) | run mode value |
| Pressure | NTA 855 oil pressure shutdown limit | 8 | psi (55 kPa) | idle mode value |
| Pressure | NTA 855 oil pressure warning limit | 12 | psi (83 kPa) | idle mode value |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | Ethylene glycol based permanent antifreeze | Precharged spin-on corrosion filters compatible with plain water and all ethylene glycol based permanent antifreeze coolants. Remote radiator requires a deareation type radiator or separate auxiliary tank with capacity at least 5% of total coolant volume. | |||
| Coolant | soft water / E.G. / DCA mixture | Cooling system to be filled with soft water/E.G./DCA mixture (on-site review checklist). | |||
| Fuel | ASTM No. 2 Diesel | Check the engine manual for fuel specifications to determine acceptability. Do not use galvanized fuel lines, fittings or tanks; do not use copper tubing for fuel lines. | |||
| Fuel | Diesel | Day tank fuel transfer pump maintains reservoir of diesel fuel in the day tank. | |||
| Grease | Lithium based grease | Mobilux No. 2 or Shell Alvania R3 | 2.74 oz (81 ml) | Generator end bearing. Temperature range -22F to +248F (-30C to +120C). Grease should be equally divided between the bearing, bearing cap cavity, and bearing cartridge cavity. | |
| Grease | Lithium based grease, Mobilux No. 2 or Shell Alvania R3 | -30°C to 120°C | 2.74 oz (81 ml) | End bearing lubricant; grease equally divided between bearing, bearing cap cavity and bearing cartridge cavity. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 101 | IDLE MODE | Indicates that the engine is operating in idle mode. Grounding the engine idle input causes generator build-up to be inhibited and the engine to be governed at 800 RPM. | Warning | Remove ground from engine idle input to return to normal speed and voltage. |
| 102 | EMERGENCY STOP | Indicates local or remote Emergency Stop. | Shutdown | Turn the switch clockwise and allow it to pop out (local only); move the Run/Off/Auto switch to Off; press the Reset switch; select Run or Auto as required. Can be reset only at the PCC front panel. |
| 200 | LOW OIL PRESSURE | Indicates engine oil pressure has dropped to an unacceptable level. | Warning | If generator is powering critical loads and cannot be shut down, wait until next shutdown period and then follow 201-SHUTDOWN procedure. Access the Oil Pressure menu prior to clearing the fault. |
| 201 | LOW OIL PRESSURE | Indicates engine oil pressure has dropped below the shutdown trip point. | Shutdown | Check oil level, lines and filters; replenish if low; reset control and restart. |
| 204 | OIL PRES SENDER | Indicates that the control has sensed that the engine oil pressure sender is out of its working range. | Warning | Check that the engine oil pressure sender is properly connected. |
| 210 | LOW COOLANT TEMP | Warning occurs when engine coolant temperature is 70°F (21°C) or lower. | Warning | Indicates engine coolant heater is not operating or is not circulating coolant. Check coolant heater power supply, low coolant level, and heater element current draw. |
| 211 | HIGH COOLANT TEMP | Indicates the engine coolant temperature is getting close to the recommended maximum temperature limit: 215° F (102° C) − standby or 207° F (97° C) − primary. | Warning | Reduce load if possible; check air inlets and outlets and remove obstructions to airflow. |
| 212 | HIGH COOLANT TEMP | Indicates engine has overheated (coolant temperature has risen above the shutdown trip point: 215 F (102 C) - standby or 207 F (97 C) - primary). | Shutdown | Check for obstructions to cooling airflow; check fan belt; check coolant mixture; check blower fan and circulation pumps; reset control and restart. |
| 213 | COOLANT SENDER | Resistance of the coolant temperature sender is out of range. | Warning | Check the resistance of the sender; should be 500 to 2k ohms. |
| 214 | LOW COOLANT LVL | Indicates engine coolant level has fallen below the trip point. | Warning | Check coolant level in radiator and coolant recovery bottle; replenish if low; look for leaks. |
| 215 | LOW COOLANT LVL | Indicates engine coolant level has fallen below the trip point. | Shutdown | Allow engine to cool; check coolant level and leakage points; reset control and restart. |
| 220 | MAG PICKUP | Mag pickup speed indication is not being sensed or does not match generator set output frequency. | Shutdown | Restart and check RPM; check PCC model setting; inspect and test MPU. |
| 221 | FAIL TO CRANK | Possible fault with control or starting system. | Shutdown | Check fuse F3 on the Engine Interface board; check battery cable connections; recharge or replace the battery. |
| 222 | OVERCRANK | Possible fuel system problem. | Shutdown | Check for empty fuel tank, leaks, plugged fuel lines; replace dirty fuel or air filter; reset and restart. |
| 223 | OVERSPEED | Indicates engine has exceeded normal operating speed. (115% ±1% of nominal). | Shutdown | Check mechanical fuel linkage and governor module/digital board duty cycle. |
| 224 | FAIL TO SYNCHRONIZE | Generator set has not synchronized to the system bus within the allowable time frame. | Warning | Check governor system stability; adjust governing and synchronizer parameters; check fuel system. |
| 226 | FAIL TO CLOSE | Paralleling breaker has been given a signal to close, but has not closed properly. | Shutdown | Verify breaker charging mechanism; check close signal; verify auxiliary contact signals. |
| 230 | LOW DC VOLTAGE | Indicates battery voltage is below 10 VDC. | Warning | Recharge or replace the battery; check the battery charger fuse. Clean and tighten battery cable connections. Check engine DC alternator; replace if normal charging voltage is not obtained. Check float level if applicable. |
| 231 | HIGH DC VOLTAGE | Indicates battery voltage exceeds 32 VDC. | Warning | Lower battery charger float level if applicable; check engine DC alternator. |
| 232 | WEAK BATTERY | Indicates battery voltage drops below 60% of nominal for two seconds, during starting. | Warning | See LOW DC VOLTAGE 230. |
| 240 | LOW FUEL−DAY | Indicates day tank fuel supply is running low. | Warning | Check fuel supply and replenish as required. |
| 241 | LOW FUEL | Low fuel signal received. | Warning | Check fuel supply and replenish; check for short to ground in external wiring. |
| 250 | EEPROM ERROR | PCC memory error; data corruption of critical operating parameters. | Shutdown | Perform the initial start setup procedure; if the set shuts down on the same EEPROM ERROR message, replace the digital board (A32). |
| 251 | EEPROM ERROR | PCC memory error; data corruption of noncritical operating parameters. | Warning | Perform the adjustment procedures; if the same message occurs, perform calibration procedures; if the message persists, replace the digital board (A32). |
| 252 | EEPROM ERROR | PCC memory error; data corruption of noncritical operating parameters. | Warning | Verify values/choices selected and repeat the save operation; if the same message occurs, replace the digital board (A32). |
| 260 | CUSTOMER FAULT 1 | When this customer defined input is closed to ground, the corresponding fault message is displayed. Programmable to initiate a shutdown or a warning. | Warning | Isolate source of false signal; repair external wiring or replace A34. |
| 261 | GROUND FAULT | When a customer defined input is closed to ground, the corresponding fault message is displayed. Default message; editable for customer site requirements. | Warning | Isolate source of false signal; repair external wiring or replace A34. |
| 262 | RUPTURE BASIN | When a customer defined input is closed to ground, the corresponding fault message is displayed. Default message; editable for customer site requirements. | Warning | Isolate source of false signal; repair external wiring or replace A34. |
| 263 | HIGH GEN TEMP | When a customer defined input is closed to ground, the corresponding fault message is displayed. Default message; editable for customer site requirements. | Warning | Isolate source of false signal; repair external wiring or replace A34. |
| 270 | PHASE ROTATION | The phase relationship between the generator set and the system bus is not matched. | Shutdown | Verify genset phase rotation matches bus; verify control wiring to bus PT module. |
| 272 | FIRST START | PowerCommand control is not receiving a proper signal from the system master first start sensor. | Warning | Verify Master First Start Sensor and interconnection wiring. |
| 301 | HIGH AC VOLTAGE | One or more phase voltages exceeded 130% of nominal, or exceeded 110% of nominal for 10 seconds. | Shutdown | Set display to GEN, VOLTS, L-N; determine if the output voltage the control sees is low or high; isolate PCC/alternator/excitation circuit. |
| 303 | LOW AC VOLTAGE | One or more phase voltages dropped below 85% of nominal for 10 seconds. | Shutdown | Check PMG/field wiring, rotating rectifier, load and connectors. |
| 313 | UNDER FREQUENCY | Indicates that engine speed has dropped below 90% of nominal for 10 seconds. Five seconds before shutdown, a Load Dump signal is initiated. | Shutdown | Check fuel supply, intake air supply and load. |
| 320 | OVERCURRENT | Indicates that generator output current has exceeded 110% of rated for 60 seconds. | Warning | Check load and load lead connections. |
| 321 | OVERCURRENT | Indicates that generator output current has exceeded 110% of rated, and that a PCC time/current calculation has initiated an overcurrent shutdown. | Shutdown | Check load and load lead connections. |
| 322 | SHORT CIRCUIT | Indicates that generator output current has exceeded 175% of rated. | Shutdown | Check load and load lead connections. |
| 330 | OVERLOAD | Three-phase power output exceeds 105% of standby (or 115% of prime) rating. | Warning | Check load and load lead connections. |
| 335 | REVERSE POWER | Power is flowing into the generator set rather than out from the unit. | Shutdown | Verify CT connections, load sharing lines, and generator set frequency/voltage. |
| 337 | LOSS OF EXCITATION | Alternator excitation system is improperly adjusted or has failed. | Shutdown | Check output voltage calibration, load sharing lines, and leading power factor loads. |
| FAULT 1 | Fault 1 (Red) | Undedicated customer-defined fault; may be programmed as timed or non-timed shutdown or fault light only. | Shutdown | Service as required by the customer-supplied fault indicating switches. |
| FAULT 2 | Fault 2 (Red) | Undedicated customer-defined fault, same features as Fault 1. | Shutdown | Service as required by the customer-supplied fault indicating switches. |
| GF | Ground Fault Alarm (Optional) | Ground fault relay monitors neutral to ground connection and line to neutral, activating a fault alarm when the connection is broken or a ground fault is sensed. | Warning | Clear fault condition by pushing the Run/Stop (Reset)/Remote switch to Reset (auto reset link set at factory). |
| HET | High Engine Temperature (Red) | Engine shut down because of excessively high engine coolant temperature (greater than 230 deg F). | Shutdown | Check coolant level and leaks; service cooling system; reset engine control. |
| HI ENG TEMP | High Engine Temperature | Engine shut down due to critically high coolant temperature (above 215F/102C). | Shutdown | |
| LET | Low Engine Temperature (Yellow) | Engine temperature is less than 70 deg F and the engine might not start. | Warning | Plug in, repair or install engine coolant and oil heaters. |
| LO FUEL | Low Fuel | Fuel supply is marginally low, if equipped (Detector-12). | Warning | |
| LO OIL PRES | Low Oil Pressure | Engine shut down due to critically low oil pressure (below 14 psi/97 kPa). | Shutdown | |
| LOP | Low Oil Pressure (Red) | Engine shut down because of excessively low engine oil pressure (less than 14 psi). | Shutdown | Check oil level and oil leaks; service lubricating system; reset engine control. |
| LOW ENG TEMP | Low Engine Temperature | Engine water jacket temperature is 70F/21C or lower; indicates possible inoperative coolant heater (Detector-12). | Warning | |
| LOW FUEL | Low Fuel (Yellow) | Fuel level in the supply tank has dropped below the reserve necessary to run the set at full load for the prescribed number of hours. | Warning | Fill the main fuel supply tank with the appropriate grade of fuel. |
| OC | Overcrank (Red) | Engine shut down because it did not start during the timed cranking period (approximately 75 seconds, including two rest periods). | Shutdown | Service the set as necessary; reset engine control. |
| OS | Overspeed (Red) | Engine shut down because of overspeed. | Shutdown | Adjust the Electronic Overspeed Module; check governor for binding; reset engine control. |
| OVERCRANK | Overcrank | Starter locked out because of excessive cranking time (limited to 75 seconds). | Shutdown | |
| OVERSPEED | Overspeed | Engine shut down because of excessive speed. | Shutdown | |
| PRE HI ENG TEMP | Pre-High Engine Temperature | Coolant temperature is marginally high (205F/97C or higher). | Warning | Attend to when generator set is shut down. |
| PRE LO OIL PRES | Pre-Low Oil Pressure | Engine oil pressure is marginally low (20 psi/138 kPa or less). | Warning | Attend to when generator set is shut down. |
| PRE-HET | Pre High Engine Temperature (Yellow) | Engine coolant temperature is abnormally high (greater than 220 deg F). | Warning | Shut down if possible or disconnect non-critical loads; service cooling system. |
| PRE-LOP | Pre Low Oil Pressure (Yellow) | Engine oil pressure is abnormally low (less than 20 psi). | Warning | Shut down if possible or disconnect non-critical loads; service lubricating system. |
| RUN | Run (Green) | Green lamp comes on when both primary and secondary starter circuits open after unit starts. | Info | |
| SWITCH OFF | Switch-off (Flashing Red) | The Run/Stop/Remote switch is in the Stop position, preventing remote automatic operation. | Info | Push the Run-Stop-Remote switch to Remote. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
⚠ Accidental starting of the generator set during this procedure presents the hazard of severe personal injury or death.
Tools: Dial indicator, Shims
⚠ Accidental starting of the generator set during this procedure presents the hazard of severe personal injury or death. Make sure to disconnect the negative (-) battery cable(s) before beginning.
Tools: Dial indicator, Wooden shims
⚠ Accidental starting during this procedure presents the hazard of severe personal injury or death.
⚠ Do not bar engine over by prying on fan blade.
Tools: dial indicator
Tools: Dial indicator with magnetic base or clamp, Torque wrench
Tools: dial indicator
Tools: Frequency meter or tachometer, Jumper wire
Tools: Dial indicator with magnetic base or clamp
⚠ Use an insulated handle screw driver to prevent electrical shock.
Tools: Insulated handle screwdriver, Frequency meter or tachometer
⚠ Touching uninsulated high voltage parts inside the control and power output boxes can result in severe personal injury or death.
Tools: Insulated handle screwdriver, AC voltmeter
⚠ HIGH VOLTAGE. Touching uninsulated high voltage parts inside the control box can result in severe personal injury or death.
Tools: Voltmeter, Jumpers, 12 volt battery
⚠ The windings of medium-voltage (601 through 15,000 volts) generator sets must be dry before the generator is operated.
Tools: Megger or insulation resistance meter, Grounding cluster, High voltage gloves
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 12 lead generator sets | Load wires are routed through the CTs | Reconnectable gensets (12 leads) have dual secondary CTs (3 pins); CT wire 2/3 to pin 2 (high voltage) or pin 3 (low voltage). | ||
| 6 lead generator sets | Generator output leads are routed through the CTs | Non-reconnectable gensets (6 leads) have single secondary CTs (2 pins). | ||
| Cummins PowerCommand generic AC Reconnect Wiring Diagram 625-2755 (Rev. D) and 625-3100 (Rev. F) | Applies to models DFAA, DFAB, DFAC, DFBF, DFCB, DFCC, DFEB, DFEC, DFFB, DFGA, DFGB, DFJA, DFJB, DFJC, DFJD, DFLB, DFLC, DFLD, DFMB (625-2755) and models DFAA-DFMB plus DFCE, DFED, DQAA, DQAB, DQBA, DQBB (625-3100). | |||
| A (U) | CT21 | U load leads (A phase) | CT dot must face the generator; CT terminal 1 connects to metering circuit, terminal 2/3 to ground. | |
| B (V) | CT22 | V load leads (B phase) | CT dot must face the generator; terminal 1 to metering circuit, terminal 2/3 to ground. | |
| C (W) | CT23 | W load leads (C phase) | CT dot must face the generator; terminal 1 to metering circuit, terminal 2/3 to ground. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Part # | Description | Category |
|---|---|---|
| UC224C | Alternator Model | Alternator |
| UC274F | Alternator Model | Alternator |
| 052045 | Lead Acid Battery - Dry (Export) | Battery |
| 011261 | Battery Lead (-VE) | Battery lead |
| 011262 | Battery Lead (+VE) | Battery lead |
| 011270 | Battery Lead, +ve | Battery lead |
| 035095 | Clamp Bolt | Bolt |
| 427560 | Battery Boot, Single Outlet | Boot |
| 427561 | Battery Boot, Copper Link | Boot |
| 035090 | Battery Clamp | Clamp |
| 049001 | Clip | Clip |
| 010156 | Heater Hose Connection | Connection |
| 010159 | 1” NPT x 16 I/D Hose Connector | Connector |
| 0300-4623-26 | DFJD (600V) | Current transformer |
| 0300-4623-51 | DFJD BR (0-480V) | Current transformer |
| 149-1689 | Element (Dual Fuel/Water Separator) | Fuel filter |
| FF202 | Fuel, Spin-On | Fuel filter |
| FS1216 | Fuel/Water Sep Spin-On | Fuel filter |
| 155-0675 | Gasket (Water Outlet) | Gasket |
| 155-1030 | Gasket (Exhaust Header) | Gasket |
| 415-0486 | Gasket (Fuel Tank - Overhead/Underground Supply) | Gasket |
| 526-0063 | Gasket (Fuel Tank) | Gasket |
| M-4352580 | Upper Gasket Set | Gasket |
| 503-0359 | Hose (1-5/8" I.D. x 3 ' )' | Hose |
| 503-0788 | Hose (Cooling System - Standpipe) | Hose |
| 518-0548-24 | Clamp, Hose | Hose |
| 3822575 | Injector and valve adjustment kit | Injector |
| 011281 | STR/STR - STR/Earth Lead (-VE) | Lead |
| 011250 | Battery Link | Link |
| 309-0243 | Valve, Control - Temperature Regulating | Marsh valve |
| 050861 | 11/4’’ NPT x 1’’ NPT Hex Nipple | Nipple |
| 715250 | M8 Steel Wing Nuts | Nut |
| 151-0399 | Controller (Electric Governor) | Service part / kit |
| 151-0419 | Actuator (Electric Governor) | Service part / kit |
| 159-0020 | Cap, Tank | Service part / kit |
| 307-0839 | Valve, Solenoid | Service part / kit |
| 307-1861 | Valve, Solenoid (Overhead Supply) | Service part / kit |
| 309-0407 | Valve, Float (Overhead Supply) | Service part / kit |
| 3096680 | Piston STC 13.8:1 Ratio | Service part / kit |
| 3096681 | Piston KT Series 15.5:1 Ratio | Service part / kit |
| 3096682 | Piston KTA Series 14.5:1 Ratio | Service part / kit |
| 3096683 | Piston 13.5:1 Ratio | Service part / kit |
| 3096684 | Piston KTA 15.7:1 Ratio | Service part / kit |
| 3096685 | Piston STC 13.9:1 Ratio | Service part / kit |
| 331-0027 | Clamp, Junction Box - Spec A through G | Service part / kit |
| 332-2634 | Clamp, Hose | Service part / kit |
| 3628731 | Piston STC Kit | Service part / kit |
| 3630913 | Piston KTA-50-G7 | Service part / kit |
| 3631241 | Piston Kit STC 13.9:1 Ratio | Service part / kit |
| 3631242 | Piston Kit 13.5:1 Ratio | Service part / kit |
| 3631243 | Piston Kit KTA 15.7:1 Ratio | Service part / kit |
| 3631244 | Piston Kit KTA Series 14.5:1 Ratio | Service part / kit |
| 3631245 | Piston Kit KT Series 15.5:1 Ratio | Service part / kit |
| 3631246 | Piston Kit STC 13.8:1 Ratio | Service part / kit |
| 3803530 | Piston Assembly STC | Service part / kit |
| 3804747 | Piston Kit KTA-50-G7 | Service part / kit |
| 3804885 | Piston KTA-50-G8/G9 | Service part / kit |
| 4089847 | Piston Kit GTA38/19 | Service part / kit |
| 4090013 | Piston Kit KTA-38-M2 | Service part / kit |
| 4090029 | Piston Kit QSK19CE | Service part / kit |
| 4090181 | Piston GTA38/19 | Service part / kit |
| 4097889 | Piston KTA-38-M2 | Service part / kit |
| 4910463 | Piston QSK19R/M | Service part / kit |
| 4910465 | Piston QSK Series | Service part / kit |
| 4916177 | Piston GTA/GQSK19 | Service part / kit |
| 4918058 | Piston QSK19CE | Service part / kit |
| 4922319 | Piston QSK19C | Service part / kit |
| 4955233 | Piston Kit QSK19R/M | Service part / kit |
| 4955235 | Piston Kit QSK Series | Service part / kit |
| 4955236 | Piston Kit QSK19C | Service part / kit |
| 4955238 | Piston Kit GTA/GQSK19 | Service part / kit |
| 508-0018 | Washer, Insulating (1/4" ID) | Service part / kit |
| 518-0548-42 | Clamp, Retainer 4 Prior To December 1996 Production (Mounted On Top And Side Of Control Box Wrapper) | Service part / kit |
| M-3804747 | Piston Kit | Service part / kit |
| V2403-M-E3BG | Engine Model | Service part / kit |
| 05050151 | Reducer, 1/2” x 1/8” NPT | Reducer |
| 706187 | M4 x 12 mm Steel Cheesehead Screw | Screw |
| 01930388 | Sender, Oil Temperature | Sensor |
| 150-0717 | Switch Assembly, Overspeed | Sensor |
| 151-0411 | Pickup, Magnetic | Sensor |
| 960-0504 | PCC Control Service Manual | Service manual |
| 960-0507 | Detector Control Service Manual | Service manual |
| 010167 | Heater Support | Support |
| 03090269 | Switch, Low Engine Temperature (LET) | Switch |
| 418520 | Battery Terminal, On Line | Terminal |
| 010112 | Thermostat | Thermostat |
| 035105 | Battery Tray | Tray |
| 716007 | M4 Plain Washer, Thick, Steel, Form A | Washer |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
The Cummins/Onan KTA38-G2 engine has an oil capacity of 129.0 liters.
The Cummins/Onan KTA38-G2 powers 1 generator set(s), including Cummins/Onan DFJB.
A commonly reported issue on generators using the Cummins/Onan KTA38-G2 is: Engine fails to start, or starts, runs and then stops. Fix: Refer to Troubleshooting Section in the Operator’s manual.