K331 Engine Engine
The K331 is an engine. It powers generator sets from Kohler, including the ES799.
Also known as: K331
Generator sets powered by this engine
1
Common problems
15- Starter not engaging
Fix: Drive pinion may be spinning. Automotive crank plants only - S1 to terminal t3 on regulator open.
Fix: *Correct connections. - No outflow (no exciter voltage-into AC volts)
Cause: Regulator relay RR could be causing overcharged or undercharged battery--check this after resistor check
Fix: Check contacts of relay CC may not be closing to complete battery charging circuit. Check brushes, AC leads, and AC armature for open circuits - No build-up.
Cause: L Open circuit between battery and field. l Battery discharged.
Fix: *Make correct connections. *l Charge battery. - Load relay L dirty or open contacts
Fix: Check for dirty or open contacts--replace relay if needed - Insufficient load
Fix: A load of 60 watts or more is needed to start automatic plant. A remote switch can be added to test run these plants--check diagrams - Generator output erratic.
Cause: L Regulator sensing terminals not connected properly.
Fix: *Check terminals 5 and 6 (120 V. connection) or terminals 5 and 7 (240 V. connection). *l Correct connections. - Generator faulty on plants with automotive cranking
Fix: Check for faulty DC generator--excessive resistance in R2 resistor. If overcharging occurs, R2 resistance may be too little - Dirty commutator.
Fix: *Clean commutator. - Cranking reset trips during cranking
Fix: Reset the reset button--if plant still does not crank, check for open circuit - Cranking contactor C contacts do not close when switch is moved to on position
Fix: Replace relay C - Choke heater circuit failure
Cause: The choke valve could ‘stick’ the air cleaner
Fix: Check the Ohm value of the resistor with a Volt-Ohmmeter. If faulty and allows higher voltage, it could cause the choke for starting - Check field circuit for open shunt
Cause: Open field resistor connection - Center tap missing on three wire automatic plants
Fix: Check for loose leads or missing center tap - Battery not being charged properly
Cause: Check condition of battery--may be sulfated or have cracked cell. Replace as needed
Fix: Check charge switch if left in HAND CRANK position, battery will not be charged
Compiled from service & troubleshooting documentation across every generator set that uses the K331.
Common questions
Which generators use the K331 engine?
The K331 powers 1 generator set(s), including Kohler ES799.
What is a common problem with the K331 engine?
A commonly reported issue on generators using the K331 is: Starter not engaging. Fix: Drive pinion may be spinning. Automotive crank plants only.