Home›Controllers›S-1A

S-1A Controller

The S-1A is a generator-set controller. It is used on generator sets from Northern Lights, including the NL843N and NL843N2.

2
Generator sets
Northern Lights
Brand
Diesel
Fuel

Generator sets using this controller

2
Northern Lights NL843NNorthern Lights NL843N2

Engines paired with this controller

1

Troubleshooting

15

Symptoms & remedies

SymptomCauseRemedy
Battery Will Not ChargeLoose or corroded connectionsClean and tighten battery connections.
Below Normal Engine TemperatureThermostat not working properlyCheck thermostat.
Engine Emits Black or Gray Exhaust SmokeClogged or dirty air cleanerService air cleaner.
Engine Emits White SmokeImproper fuelUse correct fuel for temperature.
Engine Hard to Start or Will Not StartImproper starting procedureSee starting section of this manual. Take special note of Bypass Switch operation.
Engine KnocksInsufficient oilCall your dealer.
Engine OverheatsLow coolant levelFill tank or radiator to proper level; Check hoses for loose connections and leaks.
Engine Runs Irregularly or Stalls FrequentlyBelow normal engine temperatureRemove and check thermostat.
Entire Electrical System Does Not FunctionCheck DC circuit breakerIf breaker is tripped, reset it.
High Fuel ConsumptionImproper type of fuelUse correct fuel for temperature.
High Oil ConsumptionBreak-in periodOil consumption decreases after break in.
Lack of Engine PowerIntake air restrictionService air cleaner.
Low Oil PressureLow oil levelFill crankcase to proper level.
Starter Cranks SlowlyLow battery outputBattery is too small; Battery cables are too small.
Starter InoperativeCheck DC circuit breakerIf the breaker is tripped, reset it.

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.