Home›Controllers›No-fuse Breaker

No-fuse Breaker Controller

The No-fuse Breaker is a generator-set controller. It is used on generator sets from Cummins/Onan, including the P3200i and P4300ie.

2
Generator sets
Cummins/Onan
Brand
3–3 kW
Power range
Gasoline
Fuel

Generator sets using this controller

2

Engines paired with this controller

1

Troubleshooting

9

Symptoms & remedies

SymptomCauseRemedy
Circuit Breaker TripsOverloaded circuitTurn-off some of the electrical load, and reset the circuit breaker
Cranks But Won’t StartFuel below generator pickup level in tank, Fuel supply shutoff valve closed, Carbon deposits on spark plug(s), Low oil levelAdd fuel, Fully open fuel supply valve, Remove spark plug(s) and replace, Add oil
Exhausting Black SmokeDirty air filterReplace air filter
Fails To CrankLow battery, Bad battery connection, Blown fuseCheck battery fluid level, Clean & tighten all battery & cable connections, Replace fuse on control panel
Unit Runs Then Stops, Or Stops When Driving Around A CornerLow fuel level, Low oil level, Excess oilAdd fuel, Add oil, Reduce engine oil level
Unit Runs Then SurgesLoose or worn spark plug leads, Defective ignition coil, wiring, or control components, Faulty spark plug, Governor out of adjustment, Combustion air pre-heat malfunction, Carburetor icing, Carburetor varnishingCheck spark plug leads at spark plug & ignition coil, Contact an Cummins Onan Authorized RV Service & Parts Dealer, Remove spark plug & clean or replace, Contact an Cummins Onan Authorized RV Service & Parts Dealer, Contact an Cummins Onan Authorized RV Service & Parts Dealer, Contact an Cummins Onan Authorized RV Service & Parts Dealer
Unit Starts And Runs, Then Stops When The Start Switch Is ReleasedLow fluid levels, Possible overheating, Other functional problemCheck & bring all fluids up to the appropriate levels, Check for blocked air flow or other possible causes of overheating, Contact an Cummins Onan Authorized RV Service & Parts Dealer
When Engine Fails to StartCheck if the DC circuit breaker is turned OFF. Check if the 'O_Lod' (overload) is indicated in the Multi Monitor. Check AC receptacle and DC terminals for loose connection. Check to see if engine starting was attempted with appliances already connected to generator. Depress the circuit breaker into ON position, after making sure the charging current level is proper and the battery is in the normal condition. Stop the engine and check the appliance and/or generator for overloading. Secure connection if necessary.
When No Electricity Is Generated at ReceptacleCheck fuel level. Check to make sure generator is not connected to an appliance. Check spark plug for loose spark plug cap. Check spark plug for contamination. Check engine oil level. Check if the recommended spark plug would be adopted. If empty, refill fuel tank making sure not to overfill. If connected, turn off the power switch on the connected appliance and unplug. If loose, push spark plug cap back into place. Remove spark plug and clean electrode. If the engine oil level is low, add the oil to the upper level line on the oil gauge. If not, replace with the recommended spark plug. If the recommended spark plug is not available by all means, make sure to replace with equivalent one of resistance type.

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.