HA Controller

The HA is a generator-set controller. It is used on generator sets from Cummins/Onan, including the 15.0 HA and 7.5 HA.

8
Generator sets
Cummins/Onan
Brand
Diesel
Fuel

Generator sets using this controller

8
Cummins/Onan 15.0 HACummins/Onan 7.5 HA

Also fitted to: Cummins/Onan 15.0HA-23/24D, Cummins/Onan 15.0HA-23/25D, Cummins/Onan 7.5HA-21/24D, Cummins/Onan 7.5HA-21/25D, Cummins/Onan 7.5HA-23/24D, Cummins/Onan 7.5HA-23/25D.

Troubleshooting

14

Symptoms & remedies

SymptomCauseRemedy
Automatic demand control will not start generator set with load (Spec C)Auto-manual switch not at "AUTO" or elec-start switch not at "ELEC START"Check switch positions. Auto-manual switch should be set at "AUTO," elec-start switch at "ELEC START."
Automatic demand control will not start generator set with load (Spec D)Auto-manual switch not at "AUTO" or elec-start switch not at "ELEC START"Check switch positions. Auto-manual switch should be set at "AUTO," elec-start switch at "ELEC START."
Bilge blower does not operate when load is connected (Spec D)Auto-manual switch not at "AUTO" or elec-start switch not at "ELEC START"Check switch positions. Auto-manual switch should be at "AUTO", elec-start switch at "ELEC START."
Bilge blower time delay timer does not operate6.25-ampere fuse blownBefore testing the timer, always check the 6.25-ampere fuse to see if it has blown. If the fuse is okay, connect a DC voltmeter between B+ and time delay terminal 3 on the terminal block. At the end of the time delay, the voltmeter should indicate battery voltage. The DC voltmeter connected between B+ and time delay terminal 2 should now read zero volts.
Control will not start the generator set when minimum load is applied (Spec A only)Minimum starting load set too lowAdjust the variable resistor (Figure 4-18) on the terminal board (left side—two wire models). Turn the adjustment screw with a Phillips screwdriver clockwise to increase minimum starting load, counterclockwise to decrease minimum starting load. Adjust starting resistor in small steps and check adjustments often to avoid cycling.
Demand control will not keep the generator set running with the minimum load (Spec A only)Load required for operation set too highAdjust the variable resistor on the terminal board (Figure 4-18). Turn the adjustment screw with a Phillips screwdriver counterclockwise to decrease load required for operation.
Generator set starts but does not assume load (Spec C)Incorrect generator output voltageCheck generator output voltage. See generator set operator's manual.
Generator set starts but does not assume load (Spec D)Incorrect generator output voltageCheck generator output voltage. See generator set operator's manual.
Generator set starts but stops when line contactor pulls in (Spec C)Control circuit faultMove auto-manual switch to "MANUAL" position. Connect a jumper from terminal 6 to terminal 1. Move auto-manual switch to "AUTO" position. Generator set should start and run.
Generator set starts but stops when line contactor pulls in (Spec D)Control circuit faultMove auto-manual switch to "MANUAL" position. Connect a jumper from terminal 6 to terminal 1. Move auto-manual switch to "AUTO" position. Generator set should start and run.
Generator set will not stop when load is removed (Spec C)Sufficient load keeping the control energizedPut auto-manual switch in "MANUAL" position and stop generator set with start-stop switch on engine control. Remove the lead from the load side of the contactor in the demand control. Move the auto-manual switch to "AUTO." If engine cranks, proceed to Step 5. If engine doesn't crank, put auto-manual switch to "MANUAL" position. Start engine with engine start-stop switch. Move auto-manual switch to "AUTO" position and generator set should stop. This indicates there was sufficient load to keep the control energized. Check load circuit for loads.
Generator set will not stop when load is removed (Spec D)Sufficient load keeping the control energizedPut auto-manual switch in "MANUAL" position and stop generator set with start-stop switch on engine control. Remove the lead from the load side of the contactor in the demand control. Move the auto-manual switch to "AUTO." If engine cranks, proceed to Step 5. If engine doesn't crank, put auto-manual switch to "MANUAL" position. Start engine with engine start-stop switch. Move auto-manual switch to "AUTO" position and generator set should stop. This indicates there was sufficient load to keep the control energized. Check load circuit for loads.
Line contactor will not pull in when the generator set starts, or pulls in at too low a voltage causing the generator set to cycleLine contactor pull-in voltage incorrectly adjustedAdjust the adjustable resistor in series with the line contactor coil (Figure 4-19). This is factory adjusted to pull in when the generator voltage reaches 102 to 108 volts (204 to 216 volts on 240-volt models). Do not adjust this resistor unless the line contactor will not pull in when the generator set starts or if it pulls in at too low a voltage causing the generator set to cycle.
Load sensor believed to be the source of a control malfunctionLoad sensor amplifier faultUse the troubleshooting procedures for checking components. Potentiometers (Spec A only) for adjusting starting and running are mounted on the board.

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.