| Battery High Voltage | The DC supply has risen above the high volts setting level for the duration of the high battery volts timer | |
| Battery Low Voltage | The DC supply has fallen below the low volts setting level for the duration of the low battery volts timer | |
| CAN ECU Warning | The engine ECU has detected a warning alarm and has informed the DSE module of this situation. The exact error is also indicated on the module’s display. | |
| Charge Alternator Failure | The auxiliary charge alternator voltage is low as measured from the W/L terminal. | |
| Digital Input A-D | Auxiliary Digital inputs can be user configured as Digital inputs and will display the relevant icon. | |
| Analogue Input A-C | Auxiliary Analogue inputs can be user configured as Digital inputs and will display the relevant icon. | |
| Fail To Stop | The module has detected a condition that indicates that the engine is running when it has been instructed to stop. ‘Fail to Stop’ could indicate a faulty oil pressure sensor - If engine is at rest check oil sensor wiring and configuration. | |
| Generator High Voltage Warning | The generator output voltage has risen above the pre-set pre-alarm setting. | |
| Generator Low Voltage Warning | The generator output voltage has fallen below the pre-set pre-alarm setting after the Safety On timer has expired. | |
| High Coolant Temperature Warning | The module detects that the engine coolant temperature has exceeded the high engine temperature pre-alarm setting level after the Safety On timer has expired. | |
| Low Oil Pressure Warning | The module detects that the engine oil pressure has fallen below the low oil pressure pre-alarm setting level after the Safety On timer has expired. | |
| Low Fuel Level | The module detects that the fuel level is below the configured setting | |
| Over Frequency Warning | The generator output frequency has risen above the pre-set pre-alarm setting. | |
| Over Speed Warning | The engine speed has risen above the overspeed pre alarm setting | |
| Under Frequency Warning | The generator output frequency has fallen below the pre-set pre-alarm setting after the Safety On timer has expired. | |
| Under Speed Warning | The engine speed has fallen below the underspeed pre alarm setting | |
| Flexible Sensor | The flexible sensor warning alarm has been triggered. | |
| CAN ECU Data Fail | The module is configured for CAN operation and does not detect data on the engine Can datalink. | The engine shuts down. |
| CAN ECU Shutdown | The engine ECU has detected a shutdown alarm and has informed the DSE module of this situation. The exact error is also indicated on the module’s display. | |
| Emergency Stop | The emergency stop button has been depressed. This is a failsafe (normally closed to battery negative) input and will immediately stop the set should the signal be removed. | NOTE:- The Emergency Stop Negative signal must be present otherwise the unit will shutdown. |
| Fail To Start | The engine has not fired after the preset number of start attempts | |
| Temperature sensor open circuit | Temperature sensor has been detected as being open circuit. | |
| Oil pressure sensor open circuit | Oil pressure sensor has been detected as being open circuit. | |
| Magnetic pickup open circuit | Magnetic pickup sensor has been detected as being open circuit. | |
| ry Volts | | |
| CAN ECU Power | | |
| CAN ECU Stop | | |
| Charge Alternator Shutdown | | |
| Charge Alternator Warning | | |
| Close Gen Output | | |
| Close Gen Output Pulse | | |
| Common Alarm | | |
| Common Electrical Trip | | |
| Common Shutdown | | |
| Common Warning | | |
| Energise To Stop | | |
| Fuel Relay | | |
| Gas Choke On | | |
| Gas Ignition | | |
| Generator Available | | |
| Generator High Volts Shutdown | | |
| Generator Low Volts Shutdown | | |
| Low Oil Pressure Shutdown | | |
| Flexible Sensor High Shutdown | | |
| Flexible Sensor High Warning | | |
| Flexible Sensor Low Shutdown | | |
| Flexible Sensor Low Warning | | |
| Oil Pressure Sender Open Circuit Alarm | | |
| Temperature Sender Open Circuit Alarm | | |