DGC-2020ES Controller

The DGC-2020ES is a generator-set controller.

Specifications

CommunicationsCAN Bus
ProtectionsActivation Delays, Arming Delays, Pre-Alarm Timers, Alarm Timers, Sender Fail Timers, Cranking Timers, Automatic Restart Timers, Programmable Functions Timers, Exerciser Timers

Troubleshooting

92

Fault codes

CodeMeaning
LO DAY TANK LEVEL PLow Day Tank Level
LO ECU VOLTS PLow ECU Supply Voltage
LO FUEL DLV PRESSURE ALow Fuel Delivery Pressure
LO SUPPLY VOLTS PLow Voltage Supply
LOAD TAKEOVERLoad Takeover
LOGIC OUPUT ALogic Output
LOGIC OUPUT PLogic Output
LOSS OF VOLT ALoss of Voltage
LOSS OF VOLT PLoss of Voltage
LOW BATT VOLT PLow Battery Voltage
LOW CHARGE AIR PRESS PLow Charge Air Pressure
LOW COOL LEVEL ALow Coolant Level
LOW COOL LEVEL PLow Coolant Level
LOW COOL TMP ALow Coolant Temperature
LOW COOL TMP PLow Coolant Temperature
LOW FUEL DELIV PRESS PLow Fuel Delivery Pressure
LOW FUEL LEVEL ALow Fuel Level
LOW FUEL LEVEL PLow Fuel Level
LOW FUEL RAIL PRESS PLow Fuel Rail Pressure
LOW OIL PRES ALow Oil Pressure
LOW OIL PRES PLow Oil Pressure
LOW OIL PRESSURE ALow Oil Pressure
LOW OIL PRESSURE PLow Oil Pressure
LOW STRG TANK LEVEL PLow Storage Tank Level
MAINS FAIL TESTMains Fail Test
MAINT INTERVAL PMaintenance Interval
MF TRANSFERMains Fail Transfer Complete
MF TRANSFER FAILMains Fail Transfer Fail
MN BKR CL FL PMains Breaker Fail to Close
MN BKR OP FL PMains Breaker Fail to Open
MPU FAIL PMagnetic Pickup Fail
MULTIPLE CEM PMultiple CEM-2020’s
NORM SHUTDOWNNormal Shutdown
OIL SNDR FAILOil Pressure Sender Fail
OIL SNDR FAIL AOil Pressure Sender Fail
OIL SNDR FAIL POil Pressure Sender Fail
OVERCRANK AOvercrank
OVERSPD TEST ON POverspeed Test On
OVERSPEED AOverspeed
PRIMING FAULT PPriming Fault
PROT SHUTDOWNProtective Shutdown
REV BUS ROT PReverse Bus Rotation
REV GEN ROT PReverse Generator Rotation
RUNUP SPD LO PRun Up Speed Low
SERFLASH RD FAILSerial Flash Read Fail
SPD SNDR FAILSpeed Sender Fail
SPEED DMD FL PSpeed Demand Fail
SPEED TOO LOW PEngine Speed Too Low
SS OVERRIDE ON PShutdown Override
START SPEED LOW PStart Speed Low
UNKNOWN SHUTDOWN AUnknown Shutdown
VOLTAGE SENSE FAILVoltage Sensing Fail
VOLTAGE SENSE FAIL AVoltage Sensing Fail
VOLTAGE SENSE FAIL PVoltage Sensing Fail
WEAK BATTERY PWeak Battery

Symptoms & remedies

Symptom
High Charge Air Temp mtu Pre-Alarm
High Coolant Temp mtu Alarm
High Coolant Temp mtu Pre-Alarm
High Day Tank Level
High ECU Supply Voltage Pre-Alarm
High ECU Temp Pre-Alarm
High Exhaust Temp A
High Exhaust Temp B
High Fuel Filter Diff Pressure Pre-Alarm
High Fuel Rail Pressure Pre-Alarm
High Fuel Temp Pre-Alarm
High Intercooler Temperature Pre-Alarm
High Oil Temp mtu Alarm
High Oil Temp mtu Pre-Alarm
High Pressure In 1 Pre-Alarm
High Pressure In 2 Pre-Alarm
High Storage Tank Level
High Voltage Supply Pre-Alarm
Idle Speed Low
Low After Cooler Coolant Level Alarm
Low Charge Air Coolant Level Pre-Alarm
Low Charge Air Pressure Pre-Alarm
Low Coolant Level mtu Pre-Alarm
Low Day Tank Level
Low ECU Supply Voltage Pre-Alarm
Low Fuel Delivery Pressure mtu Alarm
Low Fuel Delivery Pressure mtu Pre-Alarm
Low Fuel Rail Pressure Pre-Alarm
Low Oil Pressure mtu Alarm
Low Oil Pressure mtu Pre-Alarm
Low Storage Tank Level
Low Voltage Supply Pre-Alarm
Overspeed
Priming Fault
Run-Up Speed Low
Shutdown Override
Speed Demand Fail

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Extracted directly from this controller's manual.