Auto-Off (unspecified model) Controller

The Auto-Off (unspecified model) is a generator-set controller. It is used on generator sets from Generac, including the 7.5 kW PowerPact.

1
Generator sets
Generac
Brand
7–7 kW
Power range
Bi-Fuel (NG/LP)
Fuel

Generator sets using this controller

1

Engines paired with this controller

1

Troubleshooting

7

Symptoms & remedies

SymptomCauseRemedy
Engine cranks but will not start.1. Out of fuel. 2. Defective fuel solenoid (FS). 3. Defective spark plug(s). 4. Valve clearance out of adjustment. 5. In cold weather condition.1. Replenish fuel / Turn on fuel valve. 2. * 3. Clean, re-gap or replace plug(s). 4. Reset valve clearance. 5. Install recommended cold weather kit.
Engine starts hard and runs rough.1. Air cleaner plugged or damaged. 2. Defective spark plug(s). 3. Fuel pressure incorrect. 4. Fuel selector in wrong position.1. Check / replace air cleaner. 2. Clean, re-gap or replace plug(s). 3. Confirm fuel pressure to regulator is 10–12 in. water column (19-22 mm mercury) for LP, and 5–7 in. water column (9-13 mm mercury) for natural gas. 4. Turn fuel conversion valve to correct position.
Engine will not crank.1. Fuse blown. 2. Loose, corroded or defective battery cables. 3. Defective starter contact. 4. Defective starter motor. 5. Dead battery.1. Correct short circuit condition by replacing 7.5 Amp fuse in generator control panel. 2. Tighten, clean or replace as necessary.* 3. *See #2. 4. *See #2. 5. Charge or replace battery.
Generator is set to OFF, but the engine continues to run.1. Controller wired incorrectly 2. Defective control board.1. Repair wiring.* 2. Replace control panel*
No AC output from generator.1. Main line circuit breaker is in the OFF (or OPEN) position. 2. Generator internal failure.1. Reset circuit breaker to ON (or CLOSED). 2. *
No transfer to standby after utility source failure.1. Main line circuit breaker is in the OFF (or OPEN) position. 2. Defective transfer switch coil. 3. Defective transfer relay. 4. Transfer relay circuit open. 5. Defective control logic board.1. Reset circuit breaker to ON (or CLOSED). 2. * 3. * 4. * 5. *
Unit consumes large amounts of oil.1. Engine overfilled with oil. 2. Engine breather defective. 3. Improper type or viscosity of oil. 4. Damaged gasket, seal or hose.1. Adjust oil to proper level. 2. * 3. See Engine Oil Requirements. 4. Check for oil leaks.

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.