HomeControllersAFS Pro 700

AFS Pro 700 Controller

The AFS Pro 700 is a generator-set controller. It is used on generator sets from Case Ih, including the Axial-Flow 5140, Axial-Flow 6140 and Axial-Flow 7140.

3
Generator sets
Case Ih
Brand

Generator sets using this controller

3
Case Ih Axial-Flow 5140Case Ih Axial-Flow 6140Case Ih Axial-Flow 7140

Engines paired with this controller

2

Troubleshooting

14

Symptoms & remedies

SymptomRemedy
Damaged grain or corn in sample1. Decrease rotor speed 2. Open shoe sieve 3. Inspect concaves for plugging (unplug and set concave closer) 4. Open concave 5. Remove fillers from right of first concave (if installed) 6. Remove some wires from concaves
Distribution heavy on left side1. Remove fillers from right of first concave (if installed) 2. Open concave 3. Decrease rotor speed 4. Increase rotor speed 5. Add, remove or adjust auger bed paddle 6. Remove some wires from concaves 7. Decrease forward travel speed 8. Inspect concave for “zero” at 12th bar of the concave
Distribution heavy on right side1. Add filler to right of first concave 2. Add, remove or adjust auger bed paddle 3. Decrease rotor speed 4. Close concave 5. Decrease forward travel speed
Excess cob breakage1. Decrease rotor speed 2. Open concave 3. Remove channels from inside of rear grates
Excessive power consumption1. Increase rotor speed 2. Open concave 3. Decrease forward travel speed 4. Remove channels from inside of rear grates
Fines in sample1. Increase air blast 2. Close shoe sieve 3. Close chaffer sieve 4. Decrease rotor speed 5. Open concave
Grain blowing over chaffer1. Reduce air blast 2. Open Chaffer sieve 3. Inspect concaves for plugging (unplug and set concave closer)
Grain loss over chaffer1. Increase air blast 2. Open Chaffer sieve 3. Decrease rotor speed 4. Cover slots in rear portion of cage 5. Decrease forward travel speed
Heavy stems in sample1. Close shoe sieve 2. Close chaffer sieve 3. Increase air blast 4. Decrease rotor speed 5. Open concave
Kernels left of cob1. Increase rotor speed 2. Close concave
Loss of kernels out of rotor1. Inspect concaves for plugging (unplug and set concave closer) 2. Decrease rotor speed 3. Position grate vanes to rear or slow position 4. Remove fillers from right of first concave (if installed) 5. Remove some wires from the concave 6. Move concave vanes to rear position
Shoe sieve overloading1. Close chaffer sieve 2. Open shoe sieve 3. Increase air blast 4. Decrease rotor speed 5. Decrease forward travel speed
Small bits of cob in sample1. Close chaffer sieve 2. Decrease rotor speed 3. Close shoe sieve 4. Increase air blast 5. Open concave
Unthreshed heads or pods – white caps in sample1. Increase rotor speed 2. Close concave 3. Close Shoe Sieve 4. Add remaining fillers to first concave 5. Add filler to right of first concave

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.