Home›Controllers›1-B Start-Stop

1-B Start-Stop Controller

The 1-B Start-Stop is a generator-set controller. It is used on generator sets from Northern Lights, including the NL488K2 and NL488W2.

2
Generator sets
Northern Lights
Brand
20–20 kW
Power range
Diesel
Fuel

Generator sets using this controller

2

Engines paired with this controller

1

Troubleshooting

12

Symptoms & remedies

SymptomCauseRemedy
Below Normal Engine TemperatureThermostats not working properlyCheck thermostats.
Engine Emits Black or Gray Exhaust SmokeClogged or dirty air cleanerService air cleaner.
Engine Emits White SmokeImproper fuelUse correct fuel for temperature.
Engine Hard to Start or Will Not StartImproper starting procedureSee starting section of this manual. Take special note of Bypass Switch operation.
Engine KnocksInsufficient oilCall your dealer.
Engine OverheatsLow coolant levelFill tank or radiator to proper level.; Check hoses for loose connections and leaks.
Engine Runs Irregularly or Stalls FrequentlyBelow normal engine temperatureRemove and check thermostat.
Entire Electrical System Does Not FunctionCrankcase oil too heavyFill with oil of appropriate viscosity.
High Fuel ConsumptionImproper type of fuelUse correct fuel for temperature.
High Oil ConsumptionBreak-in periodOil consumption decreases after break in.
Lack of Engine PowerIntake air restrictionService air cleaner.
Low Oil PressureLow oil levelFill crankcase to proper level.

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.